Back to skills
SKILL.md
Timers Pwm Baremetal
ASecurityBare-metal timer and PWM skill. Use when configuring general-purpose timers for PWM, input capture, or periodic ticks without RTOS. Activates on queries about timer prescaler, PWM duty cycle, input capture, or SysTick bare-metal.
- 2 stars
- 0 votes
- 0 copies
- 0 views
- Added October 17, 2026
Security analysis
100/100npx -y skills add NetVar1337/agent-skill-canon --skill timers-pwm-baremetal --agent claude-codeAre you the author of Timers Pwm Baremetal?
Add the live security badge to your README. It updates with every re-scan.
[](https://www.skillsdirectory.com/skills/netvar1337-timers-pwm-baremetal)---
name: timers-pwm-baremetal
description: Bare-metal timer and PWM skill. Use when configuring general-purpose timers for PWM, input capture, or periodic ticks without RTOS. Activates on queries about timer prescaler, PWM duty cycle, input capture, or SysTick bare-metal.
---
# Timers and PWM (Bare-Metal)
## Purpose
Configure MCU timers for PWM output, input capture, and periodic scheduling: prescaler/ARR setup, compare channels, and SysTick as a simple tick source.
## When to Use
- Motor/LED dimming via PWM
- Measuring pulse width (input capture)
- Bare-metal `millis()` without FreeRTOS
- Hardware periodic sampling trigger
## Workflow
### 1. PWM on TIM2 CH1 (STM32)
```
f_pwm = f_timer_clk / ((PSC+1) * (ARR+1))
duty = (CCR / (ARR+1)) * 100%
```
```c
RCC->APB1ENR |= RCC_APB1ENR_TIM2EN;
TIM2->PSC = 83; /* 84MHz / 84 = 1 MHz tick */
TIM2->ARR = 999; /* 1 kHz PWM */
TIM2->CCR1 = 500; /* 50% duty */
TIM2->CCMR1 |= (6U << TIM_CCMR1_OC1M_Pos); /* PWM mode 1 */
TIM2->CCER |= TIM_CCER_CC1E;
TIM2->CR1 |= TIM_CR1_CEN;
```
GPIO: PA0 AF1 TIM2_CH1.
### 2. SysTick tick
```c
volatile uint32_t tick_ms;
void SysTick_Handler(void) {
tick_ms++;
}
void systick_init(uint32_t hz) {
SysTick_Config(SystemCoreClock / hz);
}
```
### 3. Input capture
Configure channel in `CCMR` as input, set `CCER` polarity, read `CCR` on interrupt when edge captured.
### 4. Agent usage
```
/timers-pwm-baremetal 1 kHz 25% duty PWM on TIM2 channel 1
```
## Common Problems
| Symptom | Cause | Fix |
|---------|-------|-----|
| Wrong frequency | APB timer clock doubling | Check RM timer clock x2 rule |
| No PWM output | CCER/CCMR not enabled | Enable channel output |
| Jittery tick | SysTick overridden | One owner for SysTick |
## Related Skills
- `skills/baremetal/gpio-baremetal` — timer pin AF
- `skills/embedded/freertos` — replace SysTick with RTOS tick
- `skills/baremetal/adc-dac-baremetal` — timer TRGO for ADC triggerAttribution