Incorporate the detection of the following unauthorized changes into the organizational incident response capability: [organization-defined].
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill si-7-7-integration-of-detection-and --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Si 7 7 Integration Of Detection And?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-si-7-7-integration-of-detection-and)More formats (shields.io, HTML) on the badges page.
---
name: "SI-7(7)_integration-of-detection-and-response"
description: "Incorporate the detection of the following unauthorized changes into the organizational incident response capability: [organization-defined]."
category: "input-validation"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- si-7-7
- si
- enhancement
tech_stack:
- aws
- azure
- gcp
- linux
- windows
cwe_ids:
- CWE-20
chains_with:
- AU-2
- AU-6
- IR-4
- IR-5
- SI-4
prerequisites:
- SI-7
severity_boost:
AU-2: "Chain with AU-2 for comprehensive security coverage"
AU-6: "Chain with AU-6 for comprehensive security coverage"
IR-4: "Chain with IR-4 for comprehensive security coverage"
---
# SI-7(7) Integration of Detection and Response
> **Enhancement of:** SI-7
## High-Level Description
**Family:** System and Information Integrity (SI)
**Framework:** NIST SP 800-53 Rev 5
Integrating detection and response helps to ensure that detected events are tracked, monitored, corrected, and available for historical purposes. Maintaining historical records is important for being able to identify and discern adversary actions over an extended time period and for possible legal actions. Security-relevant changes include unauthorized changes to established configuration settings or the unauthorized elevation of system privileges.
## What to Check
- [ ] Verify SI-7(7) Integration of Detection and Response is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for SI-7(7)
- [ ] Verify enhancement builds upon base control SI-7
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SI-7(7) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | -------------------------- | ------------------------------ |
| cloud-audit-mcp | Check integrity monitoring | `cloud_audit_monitoring` |
| AWS CLI | Review GuardDuty/Inspector | `aws guardduty list-detectors` |
## Remediation Guide
### Control Statement
Incorporate the detection of the following unauthorized changes into the organizational incident response capability: [organization-defined].
### Implementation Guidance
Integrating detection and response helps to ensure that detected events are tracked, monitored, corrected, and available for historical purposes. Maintaining historical records is important for being able to identify and discern adversary actions over an extended time period and for possible legal actions. Security-relevant changes include unauthorized changes to established configuration settings or the unauthorized elevation of system privileges.
## Risk Assessment
| Finding | Severity | Impact |
| ------------------------------------------------------------- | -------- | ------------------------------------------- |
| SI-7(7) Integration of Detection and Response not implemented | High | System and Information Integrity |
| SI-7(7) partially implemented | Medium | Incomplete System and Information Integrity |
## CWE Categories
| CWE ID | Title |
| ------ | ------------------------- |
| CWE-20 | Improper Input Validation |
## References
- [NIST SP 800-53 Rev 5 - SI-7(7)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=si-7.7)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (AU-2, AU-6, IR-4, IR-5, SI-4) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.