Response to Recognized Failures
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill SC-7(6)_response-to-recognized-failures --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of SC 7(6) Response To Recognized Failures?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-sc-7-6-response-to-recognized-failures)More formats (shields.io, HTML) on the badges page.
---
name: "SC-7(6)_response-to-recognized-failures"
description: "Response to Recognized Failures"
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- sc-7-6
- sc
- enhancement
tech_stack:
- aws
- azure
- gcp
- linux
- windows
- network
cwe_ids:
- CWE-311
chains_with: []
prerequisites:
- SC-7
severity_boost: {}
---
# SC-7(6) Response to Recognized Failures
> **Enhancement of:** SC-7
## High-Level Description
**Family:** System and Communications Protection (SC)
**Framework:** NIST SP 800-53 Rev 5
No description available.
## What to Check
- [ ] Verify SC-7(6) Response to Recognized Failures is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for SC-7(6)
- [ ] Verify enhancement builds upon base control SC-7
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-7(6) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | ------------------------------------- | ------------------------------------ |
| cloud-audit-mcp | Check encryption and network controls | `cloud_audit_encryption` |
| nmap | Network scanning | `nmap -sV --script ssl-enum-ciphers` |
## Remediation Guide
### Control Statement
Refer to NIST SP 800-53 Rev 5 for the full control statement.
### Implementation Guidance
Implement this control per organizational risk assessment and system categorization.
## Risk Assessment
| Finding | Severity | Impact |
| ------------------------------------------------------- | -------- | ----------------------------------------------- |
| SC-7(6) Response to Recognized Failures not implemented | High | System and Communications Protection |
| SC-7(6) partially implemented | Medium | Incomplete System and Communications Protection |
## CWE Categories
| CWE ID | Title |
| ------- | ------------------------------------ |
| CWE-311 | Missing Encryption of Sensitive Data |
## References
- [NIST SP 800-53 Rev 5 - SC-7(6)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=sc-7.6)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (none) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.