Detection of Malicious Code
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill SC-26(1)_detection-of-malicious-code --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of SC 26(1) Detection Of Malicious Code?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-sc-26-1-detection-of-malicious-code)More formats (shields.io, HTML) on the badges page.
---
name: "SC-26(1)_detection-of-malicious-code"
description: "Detection of Malicious Code"
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- sc-26-1
- sc
- enhancement
tech_stack:
- aws
- azure
- gcp
- linux
- windows
- network
cwe_ids:
- CWE-311
chains_with: []
prerequisites:
- SC-26
severity_boost: {}
---
# SC-26(1) Detection of Malicious Code
> **Enhancement of:** SC-26
## High-Level Description
**Family:** System and Communications Protection (SC)
**Framework:** NIST SP 800-53 Rev 5
No description available.
## What to Check
- [ ] Verify SC-26(1) Detection of Malicious Code is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for SC-26(1)
- [ ] Verify enhancement builds upon base control SC-26
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-26(1) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | ------------------------------------- | ------------------------------------ |
| cloud-audit-mcp | Check encryption and network controls | `cloud_audit_encryption` |
| nmap | Network scanning | `nmap -sV --script ssl-enum-ciphers` |
## Remediation Guide
### Control Statement
Refer to NIST SP 800-53 Rev 5 for the full control statement.
### Implementation Guidance
Implement this control per organizational risk assessment and system categorization.
## Risk Assessment
| Finding | Severity | Impact |
| ---------------------------------------------------- | -------- | ----------------------------------------------- |
| SC-26(1) Detection of Malicious Code not implemented | High | System and Communications Protection |
| SC-26(1) partially implemented | Medium | Incomplete System and Communications Protection |
## CWE Categories
| CWE ID | Title |
| ------- | ------------------------------------ |
| CWE-311 | Missing Encryption of Sensitive Data |
## References
- [NIST SP 800-53 Rev 5 - SC-26(1)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=sc-26.1)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (none) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!