Allow execution of permitted mobile code only in confined virtual machine environments.
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill sc-18-5-allow-execution-only-in --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Sc 18 5 Allow Execution Only In?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-sc-18-5-allow-execution-only-in)More formats (shields.io, HTML) on the badges page.
---
name: "SC-18(5)_allow-execution-only-in-confined-environments"
description: "Allow execution of permitted mobile code only in confined virtual machine environments."
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- sc-18-5
- sc
- enhancement
tech_stack:
- aws
- azure
- gcp
- linux
- windows
- network
cwe_ids:
- CWE-311
chains_with:
- SC-44
- SI-7
prerequisites:
- SC-18
severity_boost:
SC-44: "Chain with SC-44 for comprehensive security coverage"
SI-7: "Chain with SI-7 for comprehensive security coverage"
---
# SC-18(5) Allow Execution Only in Confined Environments
> **Enhancement of:** SC-18
## High-Level Description
**Family:** System and Communications Protection (SC)
**Framework:** NIST SP 800-53 Rev 5
Permitting the execution of mobile code only in confined virtual machine environments helps prevent the introduction of malicious code into other systems and system components.
## What to Check
- [ ] Verify SC-18(5) Allow Execution Only in Confined Environments is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for SC-18(5)
- [ ] Verify enhancement builds upon base control SC-18
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-18(5) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | ------------------------------------- | ------------------------------------ |
| cloud-audit-mcp | Check encryption and network controls | `cloud_audit_encryption` |
| nmap | Network scanning | `nmap -sV --script ssl-enum-ciphers` |
## Remediation Guide
### Control Statement
Allow execution of permitted mobile code only in confined virtual machine environments.
### Implementation Guidance
Permitting the execution of mobile code only in confined virtual machine environments helps prevent the introduction of malicious code into other systems and system components.
## Risk Assessment
| Finding | Severity | Impact |
| ---------------------------------------------------------------------- | -------- | ----------------------------------------------- |
| SC-18(5) Allow Execution Only in Confined Environments not implemented | High | System and Communications Protection |
| SC-18(5) partially implemented | Medium | Incomplete System and Communications Protection |
## CWE Categories
| CWE ID | Title |
| ------- | ------------------------------------ |
| CWE-311 | Missing Encryption of Sensitive Data |
## References
- [NIST SP 800-53 Rev 5 - SC-18(5)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=sc-18.5)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (SC-44, SI-7) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!