Control physical access to [organization-defined] within organizational facilities using [organization-defined].
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill PE-4_access-control-for-transmission --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of PE 4 Access Control For Transmission?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-pe-4-access-control-for-transmission)More formats (shields.io, HTML) on the badges page.
---
name: "PE-4_access-control-for-transmission"
description: "Control physical access to [organization-defined] within organizational facilities using [organization-defined]."
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- pe-4
- pe
tech_stack:
- any
cwe_ids: []
chains_with:
- AT-3
- IA-4
- MP-2
- MP-4
- PE-2
- PE-3
- PE-5
- PE-9
- SC-7
- SC-8
prerequisites: []
severity_boost:
AT-3: "Chain with AT-3 for comprehensive security coverage"
IA-4: "Chain with IA-4 for comprehensive security coverage"
MP-2: "Chain with MP-2 for comprehensive security coverage"
---
# PE-4 Access Control for Transmission
## High-Level Description
**Family:** Physical and Environmental Protection (PE)
**Framework:** NIST SP 800-53 Rev 5
Security controls applied to system distribution and transmission lines prevent accidental damage, disruption, and physical tampering. Such controls may also be necessary to prevent eavesdropping or modification of unencrypted transmissions. Security controls used to control physical access to system distribution and transmission lines include disconnected or locked spare jacks, locked wiring closets, protection of cabling by conduit or cable trays, and wiretapping sensors.
## What to Check
- [ ] Verify PE-4 Access Control for Transmission is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for PE-4
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for PE-4 implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| ------------- | --------------------------------- | ----- |
| Manual Review | Documentation and interview-based | N/A |
## Remediation Guide
### Control Statement
Control physical access to [organization-defined] within organizational facilities using [organization-defined].
### Implementation Guidance
Security controls applied to system distribution and transmission lines prevent accidental damage, disruption, and physical tampering. Such controls may also be necessary to prevent eavesdropping or modification of unencrypted transmissions. Security controls used to control physical access to system distribution and transmission lines include disconnected or locked spare jacks, locked wiring closets, protection of cabling by conduit or cable trays, and wiretapping sensors.
## Risk Assessment
| Finding | Severity | Impact |
| ---------------------------------------------------- | -------- | ------------------------------------------------ |
| PE-4 Access Control for Transmission not implemented | Medium | Physical and Environmental Protection |
| PE-4 partially implemented | Low | Incomplete Physical and Environmental Protection |
## CWE Categories
| CWE ID | Title |
| ------ | --------------------- |
| N/A | No direct CWE mapping |
## References
- [NIST SP 800-53 Rev 5 - PE-4](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=pe-4)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (AT-3, IA-4, MP-2, MP-4, PE-2) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!