Test sanitization equipment and procedures [organization-defined] to ensure that the intended sanitization is being achieved.
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill MP-6(2)_equipment-testing --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of MP 6(2) Equipment Testing?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-mp-6-2-equipment-testing)More formats (shields.io, HTML) on the badges page.
---
name: "MP-6(2)_equipment-testing"
description: "Test sanitization equipment and procedures [organization-defined] to ensure that the intended sanitization is being achieved."
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- mp-6-2
- mp
- enhancement
tech_stack:
- linux
- windows
cwe_ids: []
chains_with: []
prerequisites:
- MP-6
severity_boost: {}
---
# MP-6(2) Equipment Testing
> **Enhancement of:** MP-6
## High-Level Description
**Family:** Media Protection (MP)
**Framework:** NIST SP 800-53 Rev 5
Testing of sanitization equipment and procedures may be conducted by qualified and authorized external entities, including federal agencies or external service providers.
## What to Check
- [ ] Verify MP-6(2) Equipment Testing is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for MP-6(2)
- [ ] Verify enhancement builds upon base control MP-6
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for MP-6(2) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| ------------- | --------------------------------- | ----- |
| Manual Review | Documentation and interview-based | N/A |
## Remediation Guide
### Control Statement
Test sanitization equipment and procedures [organization-defined] to ensure that the intended sanitization is being achieved.
### Implementation Guidance
Testing of sanitization equipment and procedures may be conducted by qualified and authorized external entities, including federal agencies or external service providers.
## Risk Assessment
| Finding | Severity | Impact |
| ----------------------------------------- | -------- | --------------------------- |
| MP-6(2) Equipment Testing not implemented | Medium | Media Protection |
| MP-6(2) partially implemented | Low | Incomplete Media Protection |
## CWE Categories
| CWE ID | Title |
| ------ | --------------------- |
| N/A | No direct CWE mapping |
## References
- [NIST SP 800-53 Rev 5 - MP-6(2)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=mp-6.2)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (none) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!