Skip to content
Back to skills

Building Simulink Models

ASecurity

Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.

  • 2 stars
  • 0 votes
  • 0 copies
  • 1 view
  • Added November 17, 2026
documentationgorailsdocumentation

Works with

  • mcp

Security analysis

A100/100

Pro scans all 5 files and shows the line behind each finding

Scanned November 17, 2026

npx -y skills add zrwangems/dsh-zrwang-plugin --skill building-simulink-models --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Building Simulink Models?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Building Simulink Models
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/zrwangems-building-simulink-models/badge)](https://www.skillsdirectory.com/skills/zrwangems-building-simulink-models)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: building-simulink-models
description: Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.
license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md
metadata:
  author: MathWorks
  version: "1.7"
---
> [dsh-zrwang-plugin] 本机 MATLAB MCP 使用 existing 模式:先启动 MATLAB 并执行 shareMATLABSession(),保持会话;若工具报 failed to attach,如实告诉用户先共享 MATLAB 会话,不要绕开 MCP 改用其他方式。
# Building Models

Use `model_edit` for all structural changes — Simulink, System Composer, Simscape, and Stateflow chart internals

## When to Use

- Adding, connecting, deleting, or replacing blocks in a model
- Configuring block parameters, signal properties, or model settings
- Creating or editing Stateflow chart internals (states, transitions, junctions, data, events, messages, functions)
- Building System Composer architecture models
- Wiring Simscape physical connections

## When NOT to Use

- Querying parameter values → use `model_query_params`
- Resolving variable references to numeric values → use `model_resolve_params`

## Library & Policy Prerequisites — BLOCKING GATE

**Do this FIRST — evaluate the result before any other tool call.** Do not narrate the gate check to the user; proceed silently based on the result.

Call `library.settingsLookup()` to check for custom library configuration. It returns a struct with resolved absolute paths:
- `found` — whether a libraries file was located (satk-libraries.json or legacy reuse-libraries.json)
- `enabled` — whether custom libraries are configured
- `gatePass` — whether the gate is satisfied (can proceed to build)
- `kgIndexPath` — absolute path to `library-kg/index.md`
- `librariesPath` — absolute path to the libraries file
- `policyPath` — absolute path to `block-policy.json`
- `dataRoot` — absolute path to the directory containing `.satk/`

**Interpret the result:**

- **`found: false`** → no custom libraries configured. Proceed with standard Simulink blocks.
- **`gatePass: true, found: true`** → read `kgIndexPath` for block lookup, then plan and edit.
- **`gatePass: false`** → invoke `setup-custom-libraries` to populate the Knowledge Index.

Display meaningful description of each check and result instead of stating gate Pass/fail.


No model reading, planning, or editing begins until the gate passes.

## Workflow


0. **Ensure Library & Policy Prerequisites:** See BLOCKING GATE above. Do not proceed until gates pass.
1. **Library block lookup:**  List every block type you plan to use, search `.satk/library-kg/index.md` and the relevant category pages to find each of the library blocks that match.
2. **Read first:** Use `model_read` on the target scope to get block IDs and understand existing topology.
3. **Plan the data flow:** For complex edits, sketch inputs → operations → outputs, then map to blocks identified in Step 1 & 2.
4. **Edit:** Use `model_edit` with operations scoped to one subsystem level at a time.
5. **Verify:** Use `model_read` on the scope to confirm the structure matches your intent.
6. **Check connectivity:** After all edits in a scope are complete, run `model_check` to catch unconnected ports or dangling lines. Fix any `error`-severity issues.

**If `model_edit` returns `status: partial`:** Run both `model_read` and `model_check` immediately — don't wait until all edits are complete.

## Operation Chaining with `ref`

Use `ref` to name a block and `#ref` to reference it in later operations within the same call:

```json
[{"op": "add_block", "type": "Gain", "name": "MyGain", "ref": "g1"},
 {"op": "connect", "target": "blk_5.y1 -> #g1.u1"}]
```

In SF scope, `#ref` references are portless — no `.y1`/`.u1` suffixes (see `references/stateflow.md`).

The response `created` map shows `ref → blk_id` (or `ref → sf_X` in SF scope). In subsequent calls, use the returned ID — `#ref` only works within a single call.

## Guardrails

- **Never manually construct block path strings** from names shown in `model_overview` or `model_read`. Block names can contain invisible newlines and trailing whitespace that cause `hilite_system`, `open_system`, and `get_param` to fail. Instead, resolve paths from `blk_X` IDs:
  ```matlab
  % blk_42 → use the number after "blk_" as the SID
  blockPath = Simulink.ID.getFullName('<ModelName>:42');
  hilite_system(blockPath)
  open_system(blockPath)
  get_param(blockPath, 'BlockType')
  ```
- Do not call `Simulink.BlockDiagram.arrangeSystem` or use `set_param` for block positioning unless the user explicitly requests it. `model_edit` has a built-in autolayout engine that runs automatically after each call.
- Always pass `layout_mode` to `model_edit`. Use `"full"` when populating an empty scope (new model root, or a newly-created subsystem) for optimal block arrangement. Use `"incremental"` when adding blocks to a scope that already has existing blocks (preserves existing positions).
- For requests to fix, tidy, or rearrange an existing layout, to reposition specific blocks, or to group or expand subsystems, load the `arranging-simulink-layouts` skill.
- Each `model_edit` call operates in exactly one domain (Simulink, System Composer, or Stateflow) determined by the scope. To add a Chart block and then populate it, use two calls: SL scope for the Chart block, then SF scope for internals. Use `model_read` between calls to discover the chart's `sf_X` scope ID.
- Use meaningfully named variables (e.g., `Kp_SpeedController`) instead of hardcoded numeric values. Define variables in model workspace or a `.m` init script.
- Don't use `evaluate_matlab_code` with `set_param`/`add_block` to bypass `model_edit` — it skips autolayout, undo tracking, and error recovery
- Use `open_system` rather than `load_system` to open models that are not already open, or when creating new models, unless the user explicitly asks otherwise or the model is a library. This ensures the user can see live edits as they happen.

## Naming Conventions

Prefer code-generation-safe names for blocks, signals, and variables:

- Use only: `a-z`, `A-Z`, `0-9`, underscore (`_`)
- Don't start with a number
- Don't use leading/trailing or consecutive underscores
- Prefer names under 32 characters (required for some code generation targets)

## Block Types

Use the block's **display name** in the `type` field. Do not construct or guess library paths.

- **Custom library blocks (from `satk-libraries.json`):** pass both `type` AND `ReferenceBlock` fields. Set `type` to the block's display name and `ReferenceBlock` to the full library path from the library KG.

- **Toolbox KB blocks (from `activeToolboxes`):** Use them exactly like custom library blocks — reference the `type` and `ReferenceBlock` fields from the toolbox category page in the library KG.

- **Built-in Simulink blocks:** Use the BlockType directly: `Gain`, `Sum`, `Constant`, `Integrator`, `SubSystem`, `Scope`
- **Library blocks (Simscape, Aerospace, DSP, Communications, etc.):** Use the display name as it appears in the Simulink Library Browser: `Voltage Source`, `Resistor`, `DC Motor`, `Solver Configuration`, `6DOF (Euler Angles)`
- **If `model_edit` returns `INVALID_TYPE`:** Fall back to the full library path from MATLAB documentation (e.g., `ee_lib/Sources/Voltage Source`)

```json
[{"op": "add_block", "type": "In", "ReferenceBlock": "customLib_Portsandsubsystems/In", "name": "Voltage", "ref": "v1"},
 {"op": "add_block", "type": "Gain", "ReferenceBlock": "customLib_Mathoperations/Gain", "name": "Kp", "ref": "g1"},
 {"op": "add_block", "type": "Add", "ReferenceBlock": "customLib_Mathoperations/Add", "name": "SumErr", "ref": "s1"},
 {"op": "add_block", "type": "Out", "ReferenceBlock": "customLib_Portsandsubsystems/Out", "name": "Output", "ref": "o1"}]
```

```json
[{"op": "add_block", "type": "Voltage Source", "name": "V1", "ref": "v1"},
 {"op": "add_block", "type": "Resistor", "name": "R1", "ref": "r1"},
 {"op": "add_block", "type": "Electrical Reference", "name": "Gnd", "ref": "gnd"},
 {"op": "add_block", "type": "Solver Configuration", "name": "Solver", "ref": "sc"}]
```

## Review Gate

After completing all edits for a scope, verify:

- No `error`-severity issues from `model_check` (unconnected ports, dangling lines)
- All `ref` names resolved to `blk_id` in the `created` map — no dangling `#ref` references in subsequent calls
- Stateflow charts pass lint (`model_check` with `checks='["stateflow_lint"]'`) before layout is applied
- If `model_edit` returned `status: partial` at any point, confirm the scope is now structurally complete via `model_read`

## Domain-Specific Rules

When working with these domains, read the corresponding reference file before editing:

- **Stateflow charts** -> `references/stateflow.md` — `model_edit` edits chart internals natively. Scope to a chart (`sf_X` or chart `blk_X`) and use the same operations: `add_block` for SF elements, portless `connect` for transitions, `configure` for properties. The reference covers SF-specific syntax, scoping, LabelString patterns, and the two-call SL+SF workflow.
- **System Composer architecture models** -> `references/system-composer.md` — Create models with `systemcomposer.createModel`, then use `model_edit`. Components use `type: "SubSystem"`, ports use Bus Element blocks. The reference covers component creation, port wiring, and behavior model generation.
- **Simscape physical models** -> `references/simscape.md` — Physical connections use bidirectional `<->` syntax. The reference covers connection semantics, port patterns, and initial target variables.

----

Copyright 2026 The MathWorks, Inc.

----

Files in this skill

  • SKILL.md9.6 KB
  • manifest.yaml845 B
  • references/simscape.md2.9 KB
  • references/stateflow.md9.4 KB
  • references/system-composer.md3.7 KB

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in documentation →

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.