Skip to content
Back to skills

079 Framework 051bca77

ASecurity

Complete framework for 510(k), De Novo, and PMA submissions to the FDA. ---

  • 9 stars
  • 0 votes
  • 0 copies
  • 0 views
  • Added October 11, 2026
testinggotestingdatabasesecurityperformance

Works with

  • cli

Security analysis

A100/100

Scanned October 11, 2026

npx -y skills add tools-only/X-Skills --skill 079-framework_051bca77 --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of 079 Framework 051bca77?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for 079 Framework 051bca77
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/tools-only-079-framework-051bca77/badge)](https://www.skillsdirectory.com/skills/tools-only-079-framework-051bca77)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

SKILL.md
# FDA Submission Guide

Complete framework for 510(k), De Novo, and PMA submissions to the FDA.

---

## Table of Contents

- [Submission Pathway Selection](#submission-pathway-selection)
- [510(k) Premarket Notification](#510k-premarket-notification)
- [De Novo Classification](#de-novo-classification)
- [PMA Premarket Approval](#pma-premarket-approval)
- [Pre-Submission Program](#pre-submission-program)
- [FDA Review Timeline](#fda-review-timeline)

---

## Submission Pathway Selection

### Decision Matrix

```
Is there a legally marketed predicate device?
├── YES → Is your device substantially equivalent?
│   ├── YES → 510(k) Pathway
│   │   ├── No changes from predicate → Abbreviated 510(k)
│   │   ├── Manufacturing changes only → Special 510(k)
│   │   └── Design/performance changes → Traditional 510(k)
│   └── NO → PMA or De Novo
└── NO → Is it a novel low-to-moderate risk device?
    ├── YES → De Novo Classification Request
    └── NO → PMA Pathway (Class III)
```

### Classification Determination

| Class | Risk Level | Pathway | Examples |
|-------|------------|---------|----------|
| I | Low | Exempt or 510(k) | Bandages, stethoscopes |
| II | Moderate | 510(k) | Powered wheelchairs, pregnancy tests |
| III | High | PMA | Pacemakers, heart valves |

### Predicate Device Search

**Database Sources:**
1. FDA 510(k) Database: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm
2. FDA Product Classification Database
3. FDA PMA Database
4. FDA De Novo Database

**Search Criteria:**
- Product code (3-letter code)
- Device name keywords
- Intended use similarity
- Technological characteristics

---

## 510(k) Premarket Notification

### Required Sections (21 CFR 807.87)

#### 1. Administrative Information

```
Cover Letter
├── Submission type (Traditional/Special/Abbreviated)
├── Device name and classification
├── Predicate device(s) identification
├── Contact information
└── Signature of authorized representative

CDRH Premarket Review Submission Cover Sheet (FDA Form 3514)
├── Section A: Applicant Information
├── Section B: Device Information
├── Section C: Submission Information
└── Section D: Truth and Accuracy Statement
```

#### 2. Device Description

| Element | Required Content |
|---------|------------------|
| Device Name | Trade name, common name, classification name |
| Intended Use | Disease/condition, patient population, use environment |
| Physical Description | Materials, dimensions, components |
| Principles of Operation | How the device achieves intended use |
| Accessories | Included items, optional components |
| Variants/Models | All versions included in submission |

#### 3. Substantial Equivalence Comparison

```
Comparison Table Format:
┌────────────────────┬─────────────────┬─────────────────┐
│ Characteristic     │ Subject Device  │ Predicate       │
├────────────────────┼─────────────────┼─────────────────┤
│ Intended Use       │ [Your device]   │ [Predicate]     │
│ Technological      │                 │                 │
│ Characteristics    │                 │                 │
│ Performance        │                 │                 │
│ Safety             │                 │                 │
└────────────────────┴─────────────────┴─────────────────┘

Substantial Equivalence Argument:
1. Same intended use? YES/NO
2. Same technological characteristics? YES/NO
3. If different technology, does it raise new safety/effectiveness questions? YES/NO
4. Performance data demonstrates equivalence? YES/NO
```

#### 4. Performance Testing

**Bench Testing:**
- Mechanical/structural testing
- Electrical safety (IEC 60601-1 if applicable)
- Biocompatibility (ISO 10993 series)
- Sterilization validation
- Shelf life/stability testing
- Software verification (IEC 62304 if applicable)

**Clinical Data (if required):**
- Clinical study summaries
- Literature review
- Adverse event data

#### 5. Labeling

**Required Elements:**
- Instructions for Use (IFU)
- Device labeling (package, carton)
- Indications for Use statement
- Contraindications, warnings, precautions
- Advertising materials (if applicable)

### 510(k) Acceptance Checklist

```markdown
## Pre-Submission Verification

- [ ] FDA Form 3514 complete and signed
- [ ] User fee payment ($21,760 for FY2024, small business exemptions available)
- [ ] Device description complete
- [ ] Predicate device identified with 510(k) number
- [ ] Substantial equivalence comparison table
- [ ] Indications for Use statement (FDA Form 3881)
- [ ] Performance data summary
- [ ] Labeling (IFU, device labels)
- [ ] 510(k) summary or statement
- [ ] Truthful and Accuracy statement signed
- [ ] Environmental assessment or categorical exclusion
```

---

## De Novo Classification

### Eligibility Criteria

1. Novel device with no legally marketed predicate
2. Low-to-moderate risk (would be Class I or II if predicate existed)
3. General controls alone (Class I) or with special controls (Class II) provide reasonable assurance of safety and effectiveness

### Required Content

#### Risk Assessment

```
Risk Analysis Requirements:
├── Hazard Identification
│   ├── Biological hazards
│   ├── Mechanical hazards
│   ├── Electrical hazards
│   ├── Use-related hazards
│   └── Cybersecurity hazards (if applicable)
├── Risk Estimation
│   ├── Probability of occurrence
│   ├── Severity of harm
│   └── Risk level (High/Medium/Low)
├── Risk Evaluation
│   ├── Acceptability criteria
│   └── Benefit-risk analysis
└── Risk Control Measures
    ├── Design controls
    ├── Protective measures
    └── Information for safety
```

#### Proposed Classification

| Classification | Controls | Rationale |
|----------------|----------|-----------|
| Class I | General controls only | Low risk, general controls adequate |
| Class II | General + Special controls | Moderate risk, special controls needed |

#### Special Controls (for Class II)

Define specific controls such as:
- Performance testing requirements
- Labeling requirements
- Post-market surveillance
- Patient registry
- Design specifications

---

## PMA Premarket Approval

### PMA Application Contents

#### Technical Sections

1. **Device Description and Intended Use**
   - Detailed design specifications
   - Operating principles
   - Complete indications for use

2. **Manufacturing Information**
   - Manufacturing process description
   - Quality system information
   - Facility registration

3. **Nonclinical Laboratory Studies**
   - Bench testing results
   - Animal studies (if applicable)
   - Biocompatibility testing

4. **Clinical Investigation**
   - IDE number and approval date
   - Clinical protocol
   - Clinical study results
   - Statistical analysis
   - Adverse events

5. **Labeling**
   - Complete labeling
   - Patient labeling (if applicable)

#### Clinical Data Requirements

```
Clinical Study Design:
├── Study Objectives
│   ├── Primary endpoint(s)
│   └── Secondary endpoint(s)
├── Study Population
│   ├── Inclusion criteria
│   ├── Exclusion criteria
│   └── Sample size justification
├── Study Design
│   ├── Randomized controlled trial
│   ├── Single-arm study with OPC
│   └── Other design with justification
├── Statistical Analysis Plan
│   ├── Analysis populations
│   ├── Statistical methods
│   └── Handling of missing data
└── Safety Monitoring
    ├── Adverse event definitions
    ├── Stopping rules
    └── DSMB oversight
```

### IDE (Investigational Device Exemption)

**When Required:**
- Significant risk device clinical studies
- Studies not exempt under 21 CFR 812.2

**IDE Application Content:**
- Investigational plan
- Manufacturing information
- Investigator agreements
- IRB approvals
- Informed consent forms
- Labeling
- Risk analysis

---

## Pre-Submission Program

### Q-Submission Types

| Type | Purpose | FDA Response |
|------|---------|--------------|
| Pre-Sub | Feedback on planned submission | Written feedback or meeting |
| Informational | Share information, no feedback | Acknowledgment only |
| Study Risk | Determination of study risk level | Risk determination |
| Agreement/Determination | Binding agreement on specific issue | Formal agreement |

### Pre-Sub Meeting Preparation

```
Pre-Submission Package:
1. Cover letter with meeting request
2. Device description
3. Regulatory history (if any)
4. Proposed submission pathway
5. Specific questions (maximum 5-6)
6. Supporting data/information

Meeting Types:
- Written response only (default)
- Teleconference (90 minutes)
- In-person meeting (90 minutes)
```

### Effective Question Formulation

**Good Question Format:**
```
Question: Does FDA agree that [specific proposal] is acceptable for [specific purpose]?

Background: [Brief context - 1-2 paragraphs]

Proposal: [Your specific proposal - detailed but concise]

Rationale: [Why you believe this is appropriate]
```

**Avoid:**
- Open-ended questions ("What should we do?")
- Multiple questions combined
- Questions already answered in guidance

---

## FDA Review Timeline

### Standard Review Times

| Submission Type | FDA Goal | Typical Range |
|----------------|----------|---------------|
| 510(k) Traditional | 90 days | 90-150 days |
| 510(k) Special | 30 days | 30-60 days |
| 510(k) Abbreviated | 30 days | 30-60 days |
| De Novo | 150 days | 150-300 days |
| PMA | 180 days | 12-24 months |
| Pre-Sub Response | 70-75 days | 60-90 days |

### Review Process Stages

```
510(k) Review Timeline:
Day 0: Submission received
Day 1-15: Acceptance review
├── Accept → Substantive review begins
└── Refuse to Accept (RTA) → 180 days to respond

Day 15-90: Substantive review
├── Additional Information (AI) request stops clock
├── Interactive review may occur
└── Decision by Day 90 goal

Decision:
├── Substantially Equivalent (SE) → Clearance letter
├── Not Substantially Equivalent (NSE) → Appeal or new submission
└── Withdrawn
```

### Additional Information Requests

**Response Best Practices:**
- Respond within 30-60 days
- Use FDA's question numbering
- Provide complete responses
- Include amended sections clearly marked
- Reference specific guidance documents

---

## Submission Best Practices

### Document Formatting

- Use PDF format (PDF/A preferred)
- Bookmarks for each section
- Hyperlinks to cross-references
- Table of contents with page numbers
- Consistent headers/footers

### eSTAR (Electronic Submission Template)

FDA's recommended electronic submission format for 510(k):
- Structured data entry
- Built-in validation
- Automatic formatting
- Reduced RTA rate

### Common Refuse to Accept (RTA) Issues

| Issue | Prevention |
|-------|------------|
| Missing user fee | Verify payment before submission |
| Incomplete Form 3514 | Review all fields, ensure signature |
| Missing predicate | Confirm predicate is legally marketed |
| Inadequate device description | Include all models, accessories |
| Missing Indications for Use | Use FDA Form 3881 |
| Incomplete SE comparison | Address all characteristics |