Guides completion of a large generator interconnection application for a hybrid solar-plus-storage facility by populating required fields from source documents, flagging regulatory, site-control, technical, and credit-support issues in an internal issues memo, and analyzing available interconnection service options.
Scanned 9/11/2026
Install to Claude Code
npx -y skills add sunyifeisb-art/legalwork --skill draft-interconnection-application --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Draft Interconnection Application?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/sunyifeisb-art-draft-interconnection-application)More formats (shields.io, HTML) on the badges page.
---
name: draft-interconnection-application-hybrid-solar-storage
task_id: energy-natural-resources/draft-interconnection-application
description: Guides completion of a large generator interconnection application for a hybrid solar-plus-storage facility by populating required fields from source documents, flagging regulatory, site-control, technical, and credit-support issues in an internal issues memo, and analyzing available interconnection service options.
activates_for: [planner, solver, checker]
---
# Skill: Draft Large Generator Interconnection Application for Hybrid Solar-Plus-Storage Facility
## 1. Subject-matter triage
- Confirm the governing form, tariff attachment procedures, and any instructions for hybrid resources before filling anything in.
- Determine whether the storage component is grid-charging, generation-only charging, or mixed; treat that as a threshold fact because it can change study treatment, fee treatment, and disclosure obligations.
- Identify whether the project is a single-site filing or spans multiple parcels, and whether any prior filing, withdrawn filing, or prior study exists for the same point of interconnection.
- Separate filing-ready facts from open items that require client confirmation, transmission-provider clarification, or supplemental documentation.
## 2. Failure modes the skill is correcting
- Completing the form from project summaries without checking the tariff-specific instructions for hybrid facilities, causing missing disclosures or misclassified technical inputs.
- Treating the storage block as administratively incidental instead of analyzing whether its charging configuration triggers different queue, study, or fee consequences.
- Overlooking site-control inconsistencies across parcels, especially where lease terms do not align with the interconnection service horizon.
- Omitting a credit-support check or assuming the applicant entity itself satisfies financial qualification without support from the source documents.
- Failing to surface whether prior study data, re-filing history, or affected-system coordination changes the application posture.
- Drafting the issues memo as a general narrative rather than a decision tool that identifies each open point, its basis, impact, and next step.
- Writing the transmittal letter as a summary only, without clearly listing the filing package and any items submitted subject to confirmation.
## 3. Legal frameworks / domain conventions that apply
- FERC large generator interconnection procedures govern queue entry, study processing, and service selection for the project; apply the tariff and related form instructions as the primary authority for each field.
- Hybrid-facility treatment depends on how the storage resource is configured and charged; disclose charging assumptions and flag any need for supplemental study, separate treatment, or provider clarification under the applicable interconnection procedures.
- Site control must be sufficient for the relevant project term; any lease or easement that expires earlier than the expected service period creates a filing risk that should be identified against the form and supporting site documents.
- Creditworthiness and security requirements depend on the applicable tariff standard; if the applicant’s own financial profile is not enough, the filing package should identify the missing support and the likely security mechanism.
- Prior-filing and prior-study provisions may allow limited carryover or disclosure obligations; the source documents should be checked for queue history, withdrawal history, and any study-data reuse conditions.
- Environmental and species consultation status should be disclosed when relevant; pending consultation is not merely background and may affect timing, permitting sequence, and interconnection schedule.
- Generator step-up transformer sizing should be tested against the total project output at full operating mode, including storage discharge if the design contemplates it; undersizing can constrain operations or require redesign.
- Service-type selection should be analyzed in light of project commercialization, financing, and delivery needs, with the tariff text and source documents providing the basis for the recommendation.
- Application fee treatment for hybrid resources may depend on tariff-specific methodology; any ambiguity should be flagged for confirmation rather than assumed.
## 4. Analytical scaffolds
- Read the form, instructions, tariff attachment, and source documents together; do not populate a field until the controlling source for that field is identified.
- For each form field:
- identify the controlling source document;
- extract the exact fact or range required;
- check for internal consistency across documents;
- note any missing, conflicting, or qualification-dependent information.
- For each parcel or site-control item:
- identify the parcel;
- identify the controlling term;
- compare it to the project’s expected interconnection/service horizon;
- flag any mismatch or gap.
- For each credit-support item:
- identify the applicant entity;
- identify the stated financial qualification or support instrument;
- compare it to the tariff requirement;
- flag any shortfall or ambiguity.
- For each technical item:
- confirm whether the project description, one-line, transformer sizing, charging mode, and operating assumptions are mutually consistent;
- flag any point where the storage block changes the answer.
- For each open issue in the memo:
- state the issue;
- cite the controlling tariff provision, form instruction, or source-document basis;
- explain the filing or project consequence;
- recommend the next step.
- Where more than one service option, filing posture, parcel, or history item exists, enumerate the alternatives first, then analyze each one separately rather than collapsing them into a single pass.
## 5. Vertical / structural / temporal relationships
- Map the project structure vertically: parent applicant, project entity, site-control package, technical package, and any security support should align with each other and with the form.
- Map the project temporally: development status, permitting status, consultation status, filing date, study history, and expected commercial operation date should be internally consistent.
- Treat the storage component as temporally and operationally distinct from the generation component where the source documents do so; do not assume identical charging rights, operating limits, or fee treatment.
- If multiple parcels or documents have different end dates or assumptions, identify the earliest expiring or most restrictive item as the practical constraint.
## 6. Output structure conventions
- Produce the completed Form 1-LG as a standalone filing document populated from the source documents, with any supplemental sections needed to make the filing coherent and complete.
- Draft a transmittal cover letter that identifies the filing package, the applicant, the project, the requested interconnection posture, and any enclosed supporting materials.
- Draft a separate internal issues memo clearly marked as internal and not for filing.
- In the issues memo, use a uniform severity scale defined once at the top, and apply it consistently to each issue.
- For each issue entry, include the controlling authority or source basis, the practical impact, and a concrete recommended action.
- Address the comparative service-selection analysis explicitly, including the financing and offtake implications that support the recommendation.
- Close the memo with a Recommended Actions section that assigns the next step to the relevant role and ties it to a filing, consultation, or milestone deadline.
- Before finalizing, verify that the primary filing document is complete and non-empty, and that the cover letter and memo are secondary to the completed application rather than substitutes for it.
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!