Evaluates a model's ability to answer clinical questions about chest X-rays and localize lesions via bounding boxes. It probes visual question answering, spatial grounding, and multi-task learning in a medical imaging context. Use when the user wants to benchmark on VinDr-CXR-VQA, or asks about evaluating this task. Reports F1 score.
Scanned 9/11/2026
Install to Claude Code
npx -y skills add qhjqhj00/research-skills-pool --skill vindrcxrvqa-eval --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Vindrcxrvqa Eval?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/qhjqhj00-vindrcxrvqa-eval)More formats (shields.io, HTML) on the badges page.
---
name: vindrcxrvqa-eval
description: Evaluates a model's ability to answer clinical questions about chest X-rays and localize lesions via bounding boxes. It probes visual question answering, spatial grounding, and multi-task learning in a medical imaging context. Use when the user wants to benchmark on VinDr-CXR-VQA, or asks about evaluating this task. Reports F1 score.
metadata:
skill_kind: dataset_eval
source_arxiv: 2511.00504
bibtex_key: nguyen2025vindrcxrvqa
confidence: high
---
# vindrcxrvqa-eval
> VinDr-CXR-VQA: A Visual Question Answering Dataset for Explainable Chest X-Ray Analysis with Multi-Task Learning — Nguyen et al. (2025) (arXiv:2511.00504, 2025)
## What this evaluates
Evaluates a model's ability to answer clinical questions about chest X-rays and localize lesions via bounding boxes. It probes visual question answering, spatial grounding, and multi-task learning in a medical imaging context.
## Datasets
- **VinDr-CXR-VQA** — total ?; splits: train (20880), val (659)
## Metrics
- `F1 score` **(primary)** — range: [0, 1]
- Harmonic mean of Precision and Recall: 2 * (Prec * Rec) / (Prec + Rec). Computed on text-based lesion classification answers.
- `mIoU (TP)` — range: [0, 1]
- Mean Intersection over Union computed only over true positive predictions (IoU ≥ 0.3).
- `IoU≥0.5 (%)` — range: percent
- Percentage of validation images where at least one predicted bounding box achieves IoU ≥ 0.5 against ground truth.
- `IoU≥0.3 (%)` — range: percent
- Percentage of validation images where at least one predicted bounding box achieves IoU ≥ 0.3 against ground truth.
## Input / output format
**Input**: Chest X-ray image paired with a clinical question.
**Output**: Textual answer to the question, optionally containing bounding box coordinates embedded as special tokens (<loc_x1_y1_x2_y2>).
## Scoring recipe
```python
# VQA Classification
tp = sum(1 for p, g in zip(preds, golds) if p == g == "positive")
fp = sum(1 for p, g in zip(preds, golds) if p == "positive" and g != "positive")
fn = sum(1 for p, g in zip(preds, golds) if p != "positive" and g == "positive")
prec = tp / (tp + fp) if (tp + fp) > 0 else 0
rec = tp / (tp + fn) if (tp + fn) > 0 else 0
f1 = 2 * prec * rec / (prec + rec) if (prec + rec) > 0 else 0
# Bounding Box Localization
ious = [compute_iou(pred_box, best_gt_box) for pred_box in pred_boxes]
tp_ious = [iou for iou in ious if iou >= 0.3]
mIoU_TP = mean(tp_ious) if tp_ious else 0
good_loc_pct = sum(1 for iou in ious if iou >= 0.5) / len(ious) * 100
acceptable_loc_pct = sum(1 for iou in ious if iou >= 0.3) / len(ious) * 100
```
## Common pitfalls
- IoU threshold of 0.3 is used for detection metrics, but 0.5 is used for per-image 'good' localization; mixing these thresholds will skew results.
- mIoU is computed only over true positives (IoU ≥ 0.3), not over all predictions, which differs from standard object detection reporting.
- Bounding box coordinates are embedded as special tokens in the text output, requiring parsing before IoU calculation.
## Evidence (verbatim from paper)
> For VQA performance, we evaluate text-based lesion classification using Accuracy, Precision, Recall, and F1 score on the validation set (659 images, 5,471 ground-truth bounding boxes), comparing the pretrained baseline (zero-shot, no fine-tuning on our dataset) against our fine-tuned model. For bounding box localization, we adopt detection metrics with IoU threshold 0.3: a predicted box is a true positive (TP) if it overlaps any ground-truth box with IoU ≥ 0.3, otherwise a false positive (FP). Missed ground-truth boxes are false negatives (FN). We report Precision, Recall, F1, and mean IoU (mIoU) computed over TPs only.
## Citation
```bibtex
@misc{nguyen2025vindrcxrvqa,
title={VinDr-CXR-VQA: A Visual Question Answering Dataset for Explainable Chest X-Ray Analysis with Multi-Task Learning},
author={Nguyen et al. (2025)},
year={2025},
note={arXiv:2511.00504}
}
```
- arXiv: 2511.00504
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!