Skip to content
Back to skills

Signal Quality Auditing Eval

ASecurity

Evaluates the effectiveness of various Signal Quality Indices (SQIs) and machine learning models for classifying noisy vs. clean ECG signals, detecting outliers, and denoising time-series data. Use when the user wants to benchmark on Physionet 2011 ECG Challenge (PICC) Set A, MIT-BIH Arrhythmia & NSTDB, or asks about evaluating this task. Reports AUC, Mean Squared Error (MSE).

  • 3 stars
  • 0 votes
  • 0 copies
  • 2 views
  • Added September 11, 2026
researchpythontesting

Security analysis

A100/100

Scanned September 11, 2026

npx -y skills add qhjqhj00/research-skills-pool --skill signal-quality-auditing-eval --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Signal Quality Auditing Eval?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Signal Quality Auditing Eval
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/qhjqhj00-signal-quality-auditing-eval/badge)](https://www.skillsdirectory.com/skills/qhjqhj00-signal-quality-auditing-eval)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: signal-quality-auditing-eval
description: Evaluates the effectiveness of various Signal Quality Indices (SQIs) and machine learning models for classifying noisy vs. clean ECG signals, detecting outliers, and denoising time-series data. Use when the user wants to benchmark on Physionet 2011 ECG Challenge (PICC) Set A, MIT-BIH Arrhythmia & NSTDB, or asks about evaluating this task. Reports AUC, Mean Squared Error (MSE).
metadata:
  skill_kind: dataset_eval
  source_arxiv: 2402.00803
  bibtex_key: gao2024signal
  confidence: high
---

# signal-quality-auditing-eval

> Signal Quality Auditing for Time-series Data — Gao et al. (2024) (arXiv:2402.00803, 2024)

## What this evaluates

Evaluates the effectiveness of various Signal Quality Indices (SQIs) and machine learning models for classifying noisy vs. clean ECG signals, detecting outliers, and denoising time-series data.

## Datasets

- **Physionet 2011 ECG Challenge (PICC) Set A** — total 1996; splits: train (998), test (998)
- **MIT-BIH Arrhythmia & NSTDB** — total 18816; splits: train (9408), test (9408)

## Metrics

- `AUC` **(primary)** — range: [0, 1]
  - Area Under the Receiver Operating Characteristic curve, measuring the trade-off between true positive rate and false positive rate across classification thresholds.
- `Accuracy` — range: [0, 1]
  - Fraction of correctly classified samples out of the total number of samples.
- `Mean Squared Error (MSE)` **(primary)** — range: other
  - Average of the squared differences between the predicted denoised ECG values and the actual clean ECG ground truth values.

## Input / output format

**Input**: 10-second 12-lead ECG recordings sampled at 500 Hz, or 512-sample windows of ECG signals.

**Output**: Binary label (0=not noisy, 1=noisy) for classification/outlier tasks; continuous denoised ECG waveform for denoising task.

## Scoring recipe

```python
def evaluate(y_true, y_pred, y_clean=None):
    acc = np.mean(y_true == y_pred)
    fpr, tpr, _ = roc_curve(y_true, y_pred)
    auc = np.trapz(tpr, fpr)
    mse = np.mean((y_clean - y_pred) ** 2) if y_clean is not None else None
    return {'accuracy': acc, 'AUC': auc, 'MSE': mse}
```

## Common pitfalls

- Data leakage across subjects if not using subject-based 5-fold cross-validation.
- Using PhysioNet Set B instead of Set A, which breaks reproducibility with the reported results.
- Comparing denoising MSE across different noise types/SNR levels without normalizing or specifying the exact noise sources (EM, BW, MA, GN).

## Evidence (verbatim from paper)

> We used 5-fold group split cross-validation on the subjects in Set-A of the dataset, so subject data do not overlap in training and testing in any iteration. That yieldED 1996 ECG time-series for training and testing (50% split), each 10 seconds long, recorded at 500 Hz. These raw time-series signals are then featurized via the SQIs mentioned above. This yieldED a straightforward binary classification: 0\=not noisy, 1\=noisy. A Random Forest classifier was further trained on these SQI attributes. Table 3: Table of AUCs and Accuracies (with standard deviations) of 8 methods on subject-based 5-fold cross validation and Random Forest with only single-lead features.

## Citation

```bibtex
@misc{gao2024signal,
  title={Signal Quality Auditing for Time-series Data},
  author={Gao et al. (2024)},
  year={2024},
  note={arXiv:2402.00803}
}
```

- arXiv: 2402.00803