This benchmark evaluates how ECG sampling frequency impacts deep learning models for binary atrial fibrillation detection. It probes a model's discrimination capability and the reliability of its predicted probabilities across different temporal resolutions, while enforcing strict patient-level separation to prevent data leakage. Use when the user wants to benchmark on PTB-XL, or asks about evaluating this task. Reports AUROC.
Scanned 9/11/2026
Install to Claude Code
npx -y skills add qhjqhj00/research-skills-pool --skill ptbxl-af-detection-eval --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Ptbxl Af Detection Eval?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/qhjqhj00-ptbxl-af-detection-eval)More formats (shields.io, HTML) on the badges page.
---
name: ptbxl-af-detection-eval
description: This benchmark evaluates how ECG sampling frequency impacts deep learning models for binary atrial fibrillation detection. It probes a model's discrimination capability and the reliability of its predicted probabilities across different temporal resolutions, while enforcing strict patient-level separation to prevent data leakage. Use when the user wants to benchmark on PTB-XL, or asks about evaluating this task. Reports AUROC.
metadata:
skill_kind: dataset_eval
source_arxiv: 2604.16437
bibtex_key: mahmuod2026sampling
confidence: high
---
# ptbxl-af-detection-eval
> Sampling Matters: The Effect of ECG Frequency on Deep Learning-Based Atrial Fibrillation Detection — Arjan Mahmuod et al. (2026) (arXiv:2604.16437, 2026)
## What this evaluates
This benchmark evaluates how ECG sampling frequency impacts deep learning models for binary atrial fibrillation detection. It probes a model's discrimination capability and the reliability of its predicted probabilities across different temporal resolutions, while enforcing strict patient-level separation to prevent data leakage.
## Datasets
- **PTB-XL** — total 11005; splits: train_val (7053), test (3023)
## Metrics
- `AUROC` **(primary)** — range: [0, 1]
- Area Under the Receiver Operating Characteristic curve. Measures the model's ability to rank positive instances higher than negative ones across all classification thresholds.
- `Accuracy` — range: [0, 1]
- Proportion of correctly classified instances (true positives + true negatives) out of the total number of instances.
- `F1-score` — range: [0, 1]
- Harmonic mean of precision and recall at a 0.5 decision threshold.
- `Brier score` — range: [0, 1]
- Mean squared difference between predicted probabilities and actual binary outcomes. Lower values indicate better probabilistic accuracy.
- `ECE` — range: [0, 1]
- Expected Calibration Error. Computed by partitioning predicted probabilities into equally spaced confidence bins and calculating the weighted absolute difference between the average predicted confidence and the empirical accuracy within each bin.
## Input / output format
**Input**: 12-lead, 10-second resting ECG recordings resampled to 62, 100, 250, or 500 Hz using FFT-based interpolation, followed by per-lead Z-score standardization. Input sequence length scales linearly with sampling frequency (T = 10 × f_s).
**Output**: Softmax class probabilities over two classes (NORM, AFIB). The probability for the positive class (AFIB) is extracted as softmax(z)[:,1] from the model logits.
## Scoring recipe
```python
def compute_metrics(probs, labels):
pos_probs = probs[:, 1]
preds = (pos_probs >= 0.5).astype(int)
acc = np.mean(preds == labels)
f1 = f1_score(labels, preds)
auroc = roc_auc_score(labels, pos_probs)
brier = np.mean((pos_probs - labels)**2)
bin_edges = np.linspace(0, 1, 11)
ece = 0.0
for i in range(10):
mask = (pos_probs >= bin_edges[i]) & (pos_probs < bin_edges[i+1])
if mask.sum() > 0:
bin_acc = labels[mask].mean()
bin_conf = pos_probs[mask].mean()
ece += mask.sum() / len(labels) * abs(bin_acc - bin_conf)
return {'AUROC': auroc, 'Accuracy': acc, 'F1': f1, 'Brier': brier, 'ECE': ece}
```
## Common pitfalls
- Failing to enforce patient-level splitting, which causes data leakage and artificially inflates performance metrics.
- Applying a decision threshold to probabilities when computing calibration metrics like ECE, contradicting the protocol's requirement to use raw softmax outputs directly.
- Ignoring the natural class imbalance in the test set, as the benchmark explicitly evaluates on the real clinical prevalence rather than a balanced subset.
## Evidence (verbatim from paper)
> Model discrimination was assessed using the Area Under the Receiver Operating Characteristic curve (AUROC), classification accuracy, and F1-score. Calibration and Robustness: Beyond discrimination, we evaluated the reliability of predicted probabilities using calibration curves, the Brier score, and Expected Calibration Error (ECE). Validation logits were converted to class probabilities using softmax, and the resulting probabilities were stored for each cross-validation fold. ECE was then computed post-hoc by partitioning predicted probabilities into equally spaced confidence bins and measuring the weighted absolute difference between average confidence and empirical accuracy within each bin.
## Citation
```bibtex
@misc{mahmuod2026sampling,
title={Sampling Matters: The Effect of ECG Frequency on Deep Learning-Based Atrial Fibrillation Detection},
author={Arjan Mahmuod et al. (2026)},
year={2026},
note={arXiv:2604.16437}
}
```
- arXiv: 2604.16437
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.