Skip to content
Back to skills

Cardiac Cmr Eval

ASecurity

Evaluates automated segmentation and diagnostic classification capabilities on cardiac magnetic resonance imaging (CMR) sequences. Probes the model's ability to accurately delineate cardiac structures across multiple anatomical views and classify cardiovascular diseases with clinical-grade metrics. Use when the user wants to benchmark on BAAI Cardiac CMR Cohort, or asks about evaluating this task. Reports DSC, AUC.

  • 3 stars
  • 0 votes
  • 0 copies
  • 1 view
  • Added September 11, 2026
researchpythongoperformance

Works with

  • cli

Security analysis

A100/100

Scanned September 11, 2026

npx -y skills add qhjqhj00/research-skills-pool --skill cardiac-cmr-eval --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Cardiac Cmr Eval?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Cardiac Cmr Eval
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/qhjqhj00-cardiac-cmr-eval/badge)](https://www.skillsdirectory.com/skills/qhjqhj00-cardiac-cmr-eval)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: cardiac-cmr-eval
description: Evaluates automated segmentation and diagnostic classification capabilities on cardiac magnetic resonance imaging (CMR) sequences. Probes the model's ability to accurately delineate cardiac structures across multiple anatomical views and classify cardiovascular diseases with clinical-grade metrics. Use when the user wants to benchmark on BAAI Cardiac CMR Cohort, or asks about evaluating this task. Reports DSC, AUC.
metadata:
  skill_kind: dataset_eval
  source_arxiv: 2604.04078
  bibtex_key: qu2026baai
  confidence: high
---

# cardiac-cmr-eval

> BAAI Cardiac Agent: An intelligent multimodal agent for automated reasoning and diagnosis of cardiovascular diseases from cardiac magnetic resonance imaging — Qu et al. (2026) (arXiv:2604.04078, 2026)

## What this evaluates

Evaluates automated segmentation and diagnostic classification capabilities on cardiac magnetic resonance imaging (CMR) sequences. Probes the model's ability to accurately delineate cardiac structures across multiple anatomical views and classify cardiovascular diseases with clinical-grade metrics.

## Datasets

- **BAAI Cardiac CMR Cohort** — total 2413; splits: train (-1), val (-1), test (-1), external_val (-1)

## Metrics

- `DSC` **(primary)** — range: [0, 1]
  - Dice Similarity Coefficient measures voxel-wise overlap between predicted and ground-truth masks: 2|A∩B|/(|A|+|B|). Ranges from 0 (no overlap) to 1 (perfect match).
- `AUC` **(primary)** — range: [0, 1]
  - Area Under the Receiver Operating Characteristic Curve. Measures the model's ability to discriminate between classes across all classification thresholds. Higher values indicate better diagnostic performance.
- `F1-score` — range: [0, 1]
  - Harmonic mean of precision and recall: 2 * (precision * recall) / (precision + recall). Used for both segmentation overlap and diagnostic classification balance.

## Input / output format

**Input**: Multi-frame cardiac MRI sequences (SAX cine, 2CH cine, 4CH cine, SAX LGE) provided as 3D volumes or 2D slice stacks.

**Output**: For segmentation: binary/semantic masks per cardiac structure. For diagnosis: categorical disease labels (e.g., NH, IHD, NICM, or specific subtypes like HCM, DCM).

## Scoring recipe

```python
def compute_metrics(preds, gold):
    # Segmentation
    dsc = 2 * np.sum(preds & gold) / (np.sum(preds) + np.sum(gold))
    # Diagnosis
    tp = np.sum((preds == 1) & (gold == 1))
    fp = np.sum((preds == 1) & (gold == 0))
    fn = np.sum((preds == 0) & (gold == 1))
    precision = tp / (tp + fp + 1e-8)
    recall = tp / (tp + fn + 1e-8)
    f1 = 2 * precision * recall / (precision + recall + 1e-8)
    auc = roc_auc_score(gold, preds_prob)
    return {'DSC': dsc, 'F1': f1, 'AUC': auc}
```

## Common pitfalls

- Segmentation test set is very small (n=30), making per-sequence metric averages unstable and prone to high variance.
- Metrics are reported per sequence type (SAX, 2CH, 4CH, LGE) rather than globally averaged, complicating cross-model comparison.
- External validation uses an independent hospital cohort, so domain shift effects are not controlled for in the internal stratified split.

## Evidence (verbatim from paper)

> To ensure reliable model training and unbiased performance evaluation for the CDS and NICMS tasks, the internal dataset was partitioned into training, internal validation set, and internal test sets in a 7:1:2 ratio using a stratified split strategy that strictly follows the number distribution of CVDs categories. For normal heart (NH) screening, the model achieved an area under the curve (AUC) of 0.980 (95% confidence interval [CI]: 0.956–0.995) and an F1-score of 0.856 (95% CI: 0.782–0.914).

## Citation

```bibtex
@misc{qu2026baai,
  title={BAAI Cardiac Agent: An intelligent multimodal agent for automated reasoning and diagnosis of cardiovascular diseases from cardiac magnetic resonance imaging},
  author={Qu et al. (2026)},
  year={2026},
  note={arXiv:2604.04078}
}
```

- arXiv: 2604.04078

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.