Japan architectural code and regulatory reference. Covers the Building Standards Act (Kenchiku Kijun Ho, 1950, fundamentally revised 1998 toward performance-based regulation and 2007 strengthening post-Aneha incident), Building Standards Law Enforcement Order (Kenchiku Kijun Ho Shiko Rei) and MLIT Notifications (Kokuji); the parallel Fire Service Act and Fire Service Law Enforcement Order administered by Fire Department (Shobosho); Energy Conservation Act 1979 superseded by Act on the Improve...
Scanned 9/4/2026
Install to Claude Code
npx -y skills add NeverSight/skills_feed --skill country-japan --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Country Japan?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/neversight-country-japan)More formats (shields.io, HTML) on the badges page.
---
name: country-japan
description: >
Japan architectural code and regulatory reference. Covers the Building Standards Act
(Kenchiku Kijun Ho, 1950, fundamentally revised 1998 toward performance-based regulation
and 2007 strengthening post-Aneha incident), Building Standards Law Enforcement Order
(Kenchiku Kijun Ho Shiko Rei) and MLIT Notifications (Kokuji); the parallel Fire Service
Act and Fire Service Law Enforcement Order administered by Fire Department (Shobosho);
Energy Conservation Act 1979 superseded by Act on the Improvement of Energy Consumption
Performance of Buildings (Kenchikubutsu Sho-Energy Ho) 2015 + amendment 2022; Heart Building
Law 2006 (Barrier-Free Law) and JIS S 0026 accessibility standards; City Planning Act with
12 use districts and ratio-based regulation (Yoseki-ritsu volumetric, Kenpei-ritsu coverage,
daylighting + setback ratios); the unique two-level seismic design philosophy (Level 1
475-year + Level 2 2475-year), 1981 New Seismic Standard (Shintaishin), Energy Absorption
Member design + base isolation + damper systems; AIJ Recommendations for Loads on Buildings
2015; CASBEE (Comprehensive Assessment System for Built Environment Efficiency); BCJ
(Building Center of Japan) structural performance evaluation; Architect Law and Class 1/2/
Mokuzo (timber) architect designations; Land + Building Lease Act; and the prefecture +
Designated City (Seirei Shitei Toshi) + Core City (Chukaku Shi) administrative tiers.
---
# Country: Japan
Architectural code and regulatory reference for projects in Japan (all 47 prefectures + Tokyo Metropolis). Activate this skill on any Japanese city/prefecture reference, JPY currency, mention of "Kenchiku Kijun Ho"/"BSL"/"Sho-Energy Ho"/"CASBEE"/"AIJ"/"BCJ"/"Shintaishin", or Japanese architectural terminology (yoseki-ritsu, kenpei-ritsu, kakunin-shinsei, kanseikensa, joryoku-do, koshou-tatemono, mokuzo).
---
## 1. Regulatory Hierarchy
Japan operates as **Archetype D (Centralised National + Strong-Form Clauses)**. Building regulation is national, administered through prefectures + designated cities under Building Standards Act delegated authority. Some matters are devolved to designated cities.
### 1.1 Authority Stack
```
LEVEL 1 -- NATIONAL
Ministry of Land, Infrastructure, Transport and Tourism (MLIT, Kokudo Kotsu Sho)
Housing Bureau (Jutaku Kyoku) -- residential policy
City Bureau (Toshi Kyoku) -- urban planning
Land and Real Estate Industry Bureau
+ issues MLIT Notifications (Kokuji) -- detailed technical requirements
Ministry of Internal Affairs and Communications (Somu Sho) -- Fire Service Agency
Ministry of Health, Labour and Welfare (Kosei Rodo Sho) -- hospital regulations
Ministry of Economy, Trade and Industry (METI, Keizai Sangyo Sho) -- energy + product safety
Ministry of the Environment (Kankyo Sho) -- environmental
Ministry of Education (MEXT) -- school facilities
National Police Agency -- some safety regulations
LEVEL 2 -- PREFECTURE (todofuken) + DESIGNATED CITIES
47 prefectures + 20 Designated Cities (Seirei Shitei Toshi) -- e.g.,
Tokyo (special category as Metropolis), Osaka, Yokohama, Nagoya, Sapporo, Kobe,
Kyoto, Fukuoka, Hiroshima, Sendai, Kawasaki, Saitama, Chiba, Niigata, Hamamatsu,
Sakai, Shizuoka, Okayama, Sagamihara, Kumamoto
Tokutei Gyousei Cho (Designated Administrative Officer) -- typically prefectural or
designated-city housing department; oversees Kakunin-shinsei (building confirmation)
Building Examiners (Kenchiku Shujikan) -- public officials
Designated Confirmation Inspection Agencies (Shitei Kakunin Kensa Kikan) -- private
since 1998 reform; competitive choice
LEVEL 3 -- MUNICIPALITY (shi-cho-son)
Smaller cities, towns, villages -- if not Designated City, defer to prefecture for building
confirmation but handle planning under City Planning Act
Local Fire Departments (Shobosho)
LEVEL 4 -- PROJECT
Kakunin-shinsei (Building Confirmation Application) submitted by Class 1 Architect or
qualified delegate
Structural calculations checked: (a) self-check up to threshold (BCJ-evaluated etc.),
(b) Performance Evaluation by accredited body (BCJ, Japan Engineering Standards
Foundation, etc.) for taller/special buildings
Periodic inspection during construction (Kanseikensa)
Article 7 Inspection (kansei kensa) -- final inspection before occupancy
```
### 1.2 Building Standards Act Structure
The **Building Standards Act 1950** (BSA) was fundamentally reformed in 1998 (introducing performance-based regulation) and amended again in 2007 (post-Aneha falsified structural calculations scandal, which strengthened independent structural review).
Structure:
- **BSA itself (Kenchiku Kijun Ho)** -- legislative framework
- **BSL Enforcement Order (Kenchiku Kijun Ho Shiko Rei)** -- Cabinet Order with detailed implementing regulations
- **BSL Enforcement Regulations (Kenchiku Kijun Ho Shiko Kisoku)** -- Ministerial Order on procedure
- **MLIT Notifications (Kokuji)** -- detailed technical specifications (hundreds)
- **JIS Standards (Japanese Industrial Standards)** -- material + product specifications
### 1.3 Tokyo Special Status
Tokyo Metropolitan Government (Tokyo-to) has 23 special wards (Tokubetsu-ku) functioning as municipalities + the multi-city Tama region. Building confirmation in Tokyo's 23 wards is generally handled by the Tokyo Metropolitan Government Bureau of Urban Development + ward offices for smaller works. Tokyo has its own **Tokyo Metropolitan Ordinance on Building Standards** -- supplements BSA.
---
## 2. Building Standards Act Core Requirements
### 2.1 Building Classification (Yoto Bunkenchiku)
BSA classifies buildings by **use** + **structure** + **scale**:
| Use Category | Description |
|---|---|
| Tokushu Kenchikubutsu | Special Buildings -- assembly, hospital, school, hotel, etc.; many require BCJ structural eval, additional fire requirements |
| Ippan Kenchikubutsu | General Buildings -- offices, factories |
Special structures (high-rise, large span, special concrete) require BCJ structural performance evaluation per BSA Article 20 + sub-clauses.
### 2.2 Yoseki-ritsu + Kenpei-ritsu (Volume Ratio + Coverage)
The two principal Japanese density controls:
- **Yoseki-ritsu (容積率, FAR)** -- total above-grade GFA / lot area; values 50-1300% by use district
- **Kenpei-ritsu (建蔽率, BCR/Building Coverage Ratio)** -- footprint / lot area; values 30-80% by use district
### 2.3 Use Districts (City Planning Act -- 13 categories)
| Use District | Yoseki-ritsu Range | Kenpei-ritsu Range | Use |
|---|---|---|---|
| First Class Low-rise Residential (Daiichi-shu Tei-so Jukyo) | 50-200% | 30-60% | Houses ≤10/12 m height |
| Second Class Low-rise Residential | 50-200% | 30-60% | Similar +small shop |
| First Class Mid/High-rise Residential | 100-500% | 30-60% | Apartments + small commerce |
| Second Class Mid/High-rise Residential | 100-500% | 30-60% | + medium retail |
| First Class Residential | 100-500% | 50-80% | Residential + offices/retail moderate |
| Second Class Residential | 100-500% | 50-80% | + entertainment limited |
| Quasi-Residential | 100-500% | 50-80% | Roads + residential mix |
| Neighbourhood Commercial | 200-500% | 60-80% | Shops + service |
| Commercial | 200-1300% | 80% | Full commerce + tall buildings |
| Quasi-Industrial | 100-500% | 50-80% | Light industrial |
| Industrial | 100-400% | 50-60% | Factory mix |
| Exclusively Industrial | 100-400% | 30-60% | Heavy industry only |
| Field of Tanada | (rural special) | -- | Agricultural |
### 2.4 Sun-Right + Sky-Right + Daylighting (Hisho-mado Jisshin)
A particularly Japanese set of regulations:
- **Daylighting setback (Nichi-sho ki-zen)** -- buildings must allow specified hours of sun (3-5 hours mid-winter) to reach adjacent properties; codified per area; varies by use district
- **Sky exposure plane / road-set-back-ratio plane (Doro Shasen Seigen)** -- imaginary inclined plane from far edge of road; building cannot project beyond
- **Adjacent-property setback plane (Rinchi Shasen Seigen)** -- imaginary plane from neighbor's lot line
- **Northern exposure setback (Hokugawa Shasen)** -- protects northern neighbours from overshadowing
- **Absolute height limit** in low-rise residential -- 10 m or 12 m
These controls collectively shape Japanese urban form -- often producing characteristic "stepped" or "wedding cake" massing.
### 2.5 Structural Articles 20 + Bekkihyo (Annexes)
**BSA Article 20** sets four tiers of structural review:
- **Tier 4 (lightest)** -- low buildings; sample-rule check
- **Tier 3** -- moderate; specific structural calculation
- **Tier 2** -- high-rise or special; advanced calc + BCJ-evaluated
- **Tier 1 (heaviest)** -- super-high-rise or special structural performance; BCJ Performance Evaluation + MLIT Minister Approval required
Tier 1 cases: building > 60 m, or special types (seismic isolation building, special structural performance like FRPs, ultra-light long-span etc.)
### 2.6 Travel Distance + Egress (BSA + Enforcement Order Article 120-122)
| Parameter | Sprinklered | Unsprinklered |
|---|---|---|
| Max travel distance (general) | 50 m | 30 m |
| Max travel distance (assembly, dormitory) | 40 m | 30 m |
| Max travel distance (hospital, ROS-protected) | 50 m | 30 m |
| Min corridor width (Special Buildings >= 200 m2/floor) | 1.6 m double-loaded; 1.2 m single | -- |
| Min corridor width (residential each floor) | 1.2 m double-loaded; 0.9 m single | -- |
| Min stair width (Special Buildings >= 200 m2/floor) | 1.4 m | 1.4 m |
| Min stair width (residential >= 600 m2 total) | 1.2 m | 1.2 m |
| Min door clear width | 800 mm (Special Buildings); 750 mm (general) | -- |
### 2.7 Two Means of Escape
Two means of escape required when:
- Special Buildings any storey > 100 m2
- Mid-rise Residential > 5 storeys (or > 500 m2 floor)
- High-rise > certain thresholds
---
## 3. Seismic Design
### 3.1 Two-Level Seismic Design
The defining feature of Japanese structural design. Building must be safe under:
- **Level 1 (Damage Limit)** -- frequent earthquakes (~50-year return) -- building remains undamaged, structurally elastic. Design seismic shear coefficient C0 = 0.2 (multiplier on weight).
- **Level 2 (Life Safety / Ultimate)** -- rare earthquakes (~475-year return, possibly 2475-year for important structures) -- building may sustain damage but no collapse. Design shear coefficient C0 = 1.0.
The 1981 revision (Shintaishin -- "New Earthquake-Resistance Standard") introduced this two-level approach. Buildings built before 1981 are designated "Kyu-taishin" and many have been retrofitted.
### 3.2 Building Classifications
- **General buildings**: design per Level 1 + Level 2 capacity
- **Important buildings** (hospitals, communications, government, large assembly): design factor higher (~1.5×)
- **Hi-rise buildings** (> 60 m): site-specific seismic motion + dynamic analysis + BCJ performance evaluation
- **Base-isolated (Menshin) buildings**: separate design route + BCJ evaluation
- **Damper (Seishin) buildings**: separate design route
### 3.3 Site Classification + Seismic Coefficients
Japan ground classes (BSA Enforcement Order Article 88):
- **Class 1** (Type 1 ground -- rocky, strong) -- C0 multiplier baseline
- **Class 2** -- alluvial, moderate
- **Class 3** -- soft (e.g., Tokyo Bay landfill) -- highest C0 multiplier
### 3.4 Standards + References
- **Building Standards Act + Enforcement Order Articles 81-87 + 88**
- **AIJ Recommendations for Loads on Buildings 2015** -- Architectural Institute of Japan
- **AIJ Design Standards for Reinforced Concrete Structures (RC), Steel Structures (S), Composite (SRC)**
- **JSCE standards** -- mainly bridges/civil
- **BCJ Performance Evaluation** -- for taller buildings
---
## 4. Fire Safety (Fire Service Act + BSA)
### 4.1 Two Statute System
Japan uniquely operates fire safety under **two statutes**:
- **Building Standards Act** -- "preventive fire-resistance" (Yobo Bosai) -- structural compartmentation, fire-resistance, smoke control DESIGN
- **Fire Service Act (Shobo Ho)** -- "active fire fighting" (Soshou Bosai) -- sprinkler, detection, hose reel, evacuation equipment, fire-fighting
Plans must be approved by **both** Designated Administrative Officer (BSA) **and** Fire Department (FSA).
### 4.2 BSA Fire Provisions
- **Fire-resistant building (Taika Kenchikubutsu)** -- non-combustible structure, fire-resistance rating per height + use
- **Semi-fire-resistant (Junitaika)** -- intermediate
- **Combustible (Mokuzo + similar)** -- limited heights + areas, primarily low-rise residential
Fire-resistance hours:
- Major structural members up to 4 storeys: 1 hour
- 5-14 storeys: 2 hours
- 15+ storeys: 3 hours
### 4.3 Fire Service Act Provisions
- **Sprinklers** required: high-rise above 11 storeys, large floors (>700 m2 special), large theatre, hospital >5 storey etc.
- **Automatic fire alarms** -- per occupancy type + size
- **Indoor fire hose** + **Hose reel** -- per area
- **Smoke-removal equipment** -- per Article 126 BSA Enforcement Order
- **Emergency power** -- 30 minutes minimum, sometimes 60
### 4.4 Stair Smoke Protection
Japan emphasizes **outside-air stair (To-no-zen Kaidan)** -- stairs vented to outside, often via open balcony. Provides smoke-free escape route without requiring positive pressurization.
For tower buildings without external stair access, **smoke-resistance compartments (To-no-zen Shitsu)** are provided -- lobby + stair both pressurized or vented.
### 4.5 Post-Disaster Function -- Important Buildings
Hospitals, fire stations, government emergency operations centres, designated evacuation centres designed for **post-event functionality** -- structural drift limits tighter, redundancies for utilities, separate emergency power.
---
## 5. Energy Code (Sho-Energy Ho)
### 5.1 Act on the Improvement of Energy Consumption Performance of Buildings (Kenchikubutsu Sho-Energy Ho) 2015
Replaced the older Energy Conservation Act 1979 for buildings. Mandatory compliance for:
- **2017**: large non-residential >= 2000 m2
- **2021**: medium non-residential 300-2000 m2
- **2025** (amendment 2022 effective): ALL new buildings including small residential
Compliance demonstrated via:
- **Standard route (BEI -- Building Energy Index)** -- design primary energy / standard primary energy ≤ 1.0
- **Simplified route** for small buildings (≤300 m2) by Web Pro tool
- **Performance route** -- prescriptive UA + ηA values for envelope, similar to U-value + SHGC compliance
### 5.2 Climate Zones (Notification No. 265 of 2015 + revisions)
Japan defines **8 climate zones (Region 1 through Region 8)** based primarily on HDD (heating degree days):
| Zone | Approximate Region | Typical Cities |
|---|---|---|
| Region 1 | Sub-arctic | Hokkaido east + interior (Asahikawa, Kushiro) |
| Region 2 | Cold | Hokkaido west + Tohoku interior (Sapporo, Aomori interior) |
| Region 3 | Cool-cold | Tohoku coast + Hokuriku (Sendai, Akita, Niigata) |
| Region 4 | Cool | Inland Honshu (Nagano interior, Saitama interior) |
| Region 5 | Temperate | Tokyo, Yokohama, Osaka -- main urban regions |
| Region 6 | Mild | Western Honshu, Shikoku (Hiroshima, Takamatsu, Fukuoka) |
| Region 7 | Warm | Southern Kyushu (Kagoshima) |
| Region 8 | Subtropical | Okinawa |
### 5.3 Envelope Targets (Sho-Energy Ho Performance Route)
| Zone | UA (W/m2K) max | ηA (avg solar) max |
|---|---|---|
| 1 | 0.40 | -- |
| 2 | 0.40 | -- |
| 3 | 0.50 | -- |
| 4 | 0.60 | -- |
| 5 | 0.87 | 3.0 |
| 6 | 0.87 | 2.8 |
| 7 | 0.87 | 2.7 |
| 8 | -- | 6.7 (cooling-dominated) |
(UA = average U-value over external envelope; ηA = average solar acquisition factor)
### 5.4 ZEH and ZEB Programs
- **ZEH (Net Zero Energy House)** -- residential; tiered ZEH, ZEH Plus, ZEH+R (resilience-enhanced)
- **ZEB (Net Zero Energy Building)** -- non-residential; tiered ZEB, Nearly ZEB, ZEB Ready, ZEB Oriented
METI subsidies tied to these tiers.
### 5.5 CASBEE -- Comprehensive Assessment System for Built Environment Efficiency
Japan's own green building assessment system, comparable to LEED + DGNB. Rates by:
- **BEE (Built Environment Efficiency)** = Q (Quality) / L (Load) ratio
- Categories: S, A, B+, B-, C
- Multiple sub-tools: CASBEE for Buildings (New, Existing, Renovation), Urban Development, Cities
Many municipalities require CASBEE B+ or A as minimum for medium-large buildings.
---
## 6. Accessibility (Heart Building Law 2006)
### 6.1 Heart Building Law (Hito ni Yasashii Machizukuri / Barrier-Free Law)
**Act on Promotion of Smooth Transportation of Elderly, Disabled Persons (2006)** -- consolidated previous Heart Building Law + Traffic Barrier-Free Law.
Mandatory provisions for:
- **Designated Buildings**: shops > 2000 m2, hospitals, hotels (> 50 rooms), restaurants > 200 m2, theatres + schools above certain size, public buildings
- **Specific Designated Buildings**: subset with stricter standards
### 6.2 Key Dimensions (Heart Building Law + JIS S 0026)
| Element | Dimension |
|---|---|
| Accessible route | 1.2 m (1.5 m preferred); passing space 1.4 x 1.4 m every 50 m |
| Door clear width | 800 mm |
| Ramp gradient | 1:12 max; landings every 6 m run + at top/bottom |
| Lift cabin | 1100 x 1350 mm (Type 1); 1400 x 1600 mm (Type 2 hospital) |
| Accessible WC | 2.0 x 2.0 m; with multi-function: 2.2 x 2.2 m |
| Accessible parking | 3.5 m + access; covered preferred |
| Tactile flooring | Per JIS T 9251; at platform edges, ramps, stair tops, level changes |
### 6.3 Provision Counts
- **Accessible parking**: 1 per 50 stalls (designated buildings)
- **Multi-Function Toilet** (Tashinooyo Toiret): at least 1 per floor in designated buildings -- combines accessible WC + diaper change + ostomy + emergency call
- **Hotel accessible rooms**: 1 per 50 rooms (designated)
- **Tactile guidance**: comprehensive in transit + public buildings
### 6.4 Universal Design Beyond Compliance
Japan's robust UD culture extends beyond legal minimum:
- Many municipalities have Universal Design Mark / Tsugou (Convenience) certifications
- "ChojuJuutaku" (Long-Life Quality Housing) certification for housing
- "Tokutei Hyouka" Designated Evaluation for housing accessibility
---
## 7. Structural Materials and Standards
### 7.1 Material Codes
| Material | Reference |
|---|---|
| Reinforced Concrete | AIJ-RC / JASS 5 |
| Steel Structures | AIJ-S / JASS 6 |
| Composite (Steel-Reinforced Concrete -- SRC) | AIJ-SRC |
| Wood / Timber | AIJ-W / JASS 11 / JAS lumber + glulam standards |
| Masonry | AIJ-M / JIS A 5406 (block) |
| Foundations | AIJ-F / BSA Articles + JIS A 5525 (piles) |
### 7.2 JIS Standards
The Japanese Industrial Standards (JIS) provide product-level specifications:
- JIS A series -- civil + building
- JIS B -- machinery
- JIS C -- electrical
- JIS G -- iron + steel
### 7.3 Wind (AIJ Recommendations 2015)
Japan uses **basic wind velocity (Vref)** at 30 m height -- varies city by city per AIJ map. Tokyo Vref = 34 m/s. Okinawa coastal (typhoon-prone) Vref up to 46 m/s.
Wind-resistant design also separate consideration:
- **Wind-cycle fatigue** for tall buildings
- **Aerodynamic shape coefficients** per wind tunnel testing for >60 m
- **Cyclonic/typhoon design** distinct from synoptic wind, especially in Okinawa + Kyushu
---
## 8. Permit Workflow
### 8.1 Standard Workflow (Kakunin-shinsei)
1. **Pre-application consultation** (Jizen Sodan) with prefecture/Designated City Building Department
2. **Preliminary calculations** by Class 1 Architect (Ichi-kyu Kenchikushi)
3. **Submit Building Confirmation Application (Kakunin-shinsei)** to designated administrative officer OR private confirmation inspection agency
4. **Confirmation Certificate issued (Kakunin Tsuuchi-sho)** within statutory period (varies; 7-35 days)
5. **Structural Calculation Conformance Judgment (Kouzou Keisan Tekigosei Hantei)** -- if Tier 2/3 structural -- by accredited body
6. **Performance Evaluation** by BCJ (or other accredited) -- if Tier 1 structural
7. **MLIT Minister Approval** -- if super-high-rise OR special structure
8. **Periodic Inspections during construction** (Chuukan Kensa)
9. **Article 7 Inspection** (Kanseikensa) -- final
10. **Inspection Certificate (Kanseikensa-Shomeisho)** -- equivalent to certificate of occupancy
### 8.2 Architect Licensing
- **Class 1 Architect (Ichi-kyu Kenchikushi)** -- can design any building scale
- **Class 2 Architect (Ni-kyu Kenchikushi)** -- limited to certain scales/structures
- **Mokuzo Kenchikushi (Wood-Structure Architect)** -- limited to wooden buildings
- Examinations administered by MLIT-designated body; renewed periodically with CPD
### 8.3 Special Buildings -- Building Center of Japan (BCJ) Role
BCJ evaluates buildings beyond standard limits:
- **Super-high-rise** (>60 m) -- structural performance evaluation
- **Base-isolated** (Menshin)
- **Special structural systems** (cable-stayed, tensile, etc.)
- **Long-span** structures
- **Special materials** (CLT large-scale, etc.)
BCJ issues evaluation certificate which the Confirmation Inspection Agency relies on.
---
## 9. Climate Design Parameters
### 9.1 Tokyo (Region 5)
| Parameter | Value |
|---|---|
| Cooling design DB (0.4%) | 32-34 deg C |
| Cooling design WB | 26-27 deg C |
| Heating design DB (99.6%) | 0 to -2 deg C |
| Annual CDD (base 18C) | 1100-1300 |
| Annual HDD (base 18C) | 2000-2200 |
| Annual GHI | 1400 kWh/m2 |
| Wind 3-sec gust (typhoon) | 50-55 m/s 0.4% probability |
| Snowfall | < 100 mm typical / yr |
### 9.2 Sapporo (Region 2)
| Parameter | Value |
|---|---|
| Heating design DB | -8 to -10 deg C |
| Annual HDD | 3500+ |
| Snow ground load | 1.5-3.5 kN/m2 (depends on neighbourhood) |
### 9.3 Okinawa (Region 8)
| Parameter | Value |
|---|---|
| Cooling design DB | 32-33 deg C |
| Cooling design WB | 28 deg C |
| Annual CDD | 5000+ |
| Annual HDD | ~50 |
| Typhoon wind | extreme; design 60+ m/s 3-sec gust |
| Salt-laden corrosion | severe |
---
## 10. Quick Numeric Reference
| Parameter | Value | Source |
|---|---|---|
| Floor-to-floor residential | 2.8-3.0 m | BSA + practice |
| Floor-to-floor office | 3.5-4.0 m | Class A spec; 2.5 m min clear |
| Hotel ceiling clear | 2.4 m min | BSA |
| Corridor width residential (multi-storey) | 1.2 m | BSA Enforcement Order 119 |
| Corridor width Special Building | 1.6 m | BSA Enforcement Order 119 |
| Stair width residential | 1.2 m | BSA Enforcement Order 23 |
| Stair max riser | 23 cm (residential); 18 cm (Special) | BSA |
| Stair min going | 15 cm (residential); 24 cm (Special) | BSA |
| Travel distance sprinklered (general) | 50 m | BSA Enforcement Order 120 |
| Seismic C0 (Level 1) | 0.2 | BSA + AIJ-S |
| Seismic C0 (Level 2) | 1.0 (general); 1.5 (important) | BSA + AIJ-S |
| UA Tokyo (Region 5) | 0.87 W/m2K max | Sho-Energy Ho |
| Yoseki-ritsu Commercial | 200-1300% | City Planning Act |
| Kenpei-ritsu Residential | 30-60% | City Planning Act |
| Daylight hours required (Region 5 winter) | 3 hours mid-winter | Local ordinance |
---
## 11. Application Workflow
1. **Identify prefecture / Designated City** (or special wards in Tokyo).
2. **Identify use district + yoseki-ritsu + kenpei-ritsu + height limit + daylighting setbacks**.
3. **Determine if Special Building (Tokushu Kenchikubutsu)**.
4. **Determine structural review tier** (1, 2, 3, 4) per BSA Article 20.
5. **Apply BSA + Enforcement Order + MLIT Notifications** for general design.
6. **Apply Fire Service Act + Local Fire Department** for fire-fighting systems.
7. **Apply Sho-Energy Ho** for energy.
8. **Apply Heart Building Law** if Designated Building scale.
9. **Apply AIJ-RC / AIJ-S / AIJ-W standards** for structural materials.
10. **Engage BCJ or other accredited body** if structural performance evaluation needed.
11. **Cite clauses**: "Building Standards Act Article 20", "BSA Enforcement Order Article 120", "MLIT Notification 1457 of 2000 (Kokuji)", "AIJ Recommendations for Loads on Buildings 2015", "Sho-Energy Ho 2015 Article 11", "Heart Building Law Implementation Standards Section 13".
---
## 12. Authoritative Sources
- **MLIT (Ministry of Land, Infrastructure, Transport and Tourism)** -- mlit.go.jp
- **Building Center of Japan (BCJ, Nihon Kenchiku Center)** -- bcj.or.jp -- structural evaluation, technical guidelines
- **Japan Architectural Institute (AIJ, Nihon Kenchiku Gakkai)** -- aij.or.jp -- structural recommendations
- **Architectural Institute of Japan -- JASS series** -- Japanese Architectural Standard Specifications
- **JIS via Japan Standards Association (JSA)** -- jsa.or.jp
- **Fire and Disaster Management Agency (FDMA, Shobo Cho)** -- fdma.go.jp
- **Japan Society of Civil Engineers (JSCE)** -- jsce.or.jp
- **Institute for Building Environment + Energy Conservation (IBEC)** -- ibec.or.jp -- CASBEE
- **METI (Ministry of Economy, Trade and Industry)** -- meti.go.jp -- ZEB/ZEH subsidies
- **Japan Sustainable Building Database (CASBEE certified projects)** -- ibec.or.jp/CASBEE
- **Tokyo Metropolitan Government Bureau of Urban Development** -- toshiseibi.metro.tokyo.lg.jp
- **Each prefecture building department** -- prefectural government websites
- **Architect license examination via Japan Architects Association** -- jia.or.jp
---
*Cross-references: load `building-codes` for general code structure (Japan BSA is distinct -- two-statute fire system); `fire-life-safety` for general principles overlaid by BSA fire-resistance + Fire Service Act active provisions; `accessibility-design` for global frameworks then Heart Building Law; `building-sustainability` for CASBEE + LEED + Passivhaus comparison; `structural-systems` for seismic-specific design (Japan two-level + base isolation expertise); `building-envelope` for severe climate (subarctic to subtropical) + typhoon detailing.*
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!