Port MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface (daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners, queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput, start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts, converting session-API calls, working with DataAcquisition objects, writing multi-feature DAQ scripts that combine triggers, callbacks, continuo...
Scanned 9/5/2026
Install to Claude Code
npx -y skills add matlab/matlab-agentic-toolkit --skill matlab-modernize-daq --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Matlab Modernize Daq?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/matlab-matlab-modernize-daq)More formats (shields.io, HTML) on the badges page.
---
name: matlab-modernize-daq
description: >
Port MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface
(daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners,
queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput,
start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts,
converting session-API calls, working with DataAcquisition objects, writing multi-feature
DAQ scripts that combine triggers, callbacks, continuous acquisition, or analog output.
Also use when a user says their DAQ script "used to work" or "errors on R20XX",
since modernizing legacy session-API code is a frequent fix for those failures.
Trigger keywords: daq, DAQ, NI, session interface, addtrigger, addclock, ScansAvailableFcn,
ScansRequiredFcn, daq.createSession, addAnalogInputChannel, startBackground,
queueOutputData, DataAvailable, evt.Data, evt.TimeStamps, wait(d), preload,
discouraged, legacy, modernize, R2020a.
license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md
metadata:
author: MathWorks
version: "1.0"
---
# Port DAQ Code to the Modern DataAcquisition Interface
Translate legacy session-based Data Acquisition Toolbox code (`daq.createSession`, `addAnalogInputChannel`, `DataAvailable` listeners, `startBackground`, `queueOutputData`, `wait`) to the modern `DataAcquisition` interface introduced in R2020a (`daq("ni")`, `addinput`, `ScansAvailableFcn`, `start`, `write`, `preload`). Also covers writing new multi-feature DAQ scripts where the modern API patterns are easy to get wrong under cognitive load.
## When to Use
- Porting an existing script that calls `daq.createSession`, `addAnalogInputChannel`, `addAnalogOutputChannel`, `addCounterInputChannel`, `addCounterOutputChannel`, or `addDigitalChannel`.
- Replacing `DataAvailable` / `DataRequired` / `ErrorOccurred` listeners with `ScansAvailableFcn` / `ScansRequiredFcn` / `ErrorOccurredFcn`.
- Replacing `startBackground` / `startForeground` / `s.wait()` lifecycle calls.
- Replacing `queueOutputData` with `preload` + `write`.
- Writing a **new** DAQ script that combines two or more of: external triggers, continuous acquisition, callback-driven streaming, analog output with refill, or cross-callback state.
- Debugging errors like `Undefined function 'wait' for input arguments of type 'daq.interfaces.DataAcquisition'` or `Unrecognized method, property, or field 'Data' for class 'matlabshared.asyncio.buffer.ElementsAvailableInfo'`.
## When NOT to Use
- Single-channel foreground acquisition with no trigger and no callbacks (e.g. "acquire 1 s of voltage from ai0 at 10 kHz and plot"). The modern API is straightforward at this scale and this skill would be unnecessary overhead.
- Picking a DAQ vendor or evaluating non-NI hardware. This skill's evidence base is NI.
- Signal processing or analysis of already-acquired data (filtering, spectral analysis, etc.). This skill only covers acquiring and generating data through the DataAcquisition interface, not post-processing it.
- Simulink, App Designer, or real-time-target DAQ workflows.
- Modernizing `matlab.unittest` test suites or framework-style test classes (parameterized fixtures, `assumeTrue` gating, arity-contract tests, helper-class hierarchies). The API substitutions in this skill apply, but the test-harness scaffolding (parent-class stripping, fixture redesign, retiring tests that target removed contracts) is out of scope. Use this skill to translate the API calls inside test bodies, then make the harness-level judgment calls separately.
## Workflow
When porting a session-based script or composing a new multi-feature DAQ script, follow this order. Verify after every step — most failure modes in this domain are silent.
1. **Inventory the legacy script (porting only).** Identify: device(s), channel types, rate, continuous vs finite, trigger/clock connections, callbacks (`DataAvailable`/`DataRequired`/`ErrorOccurred`), state shared across callbacks, output queueing.
2. **Translate vocabulary.** Map every session-API token to its modern counterpart. Consult [`references/session-to-modern-mapping.md`](references/session-to-modern-mapping.md) — load it whenever a session-API token appears in the legacy script. Common silent-rename traps: `NotifyWhenDataAvailableExceeds` → `ScansAvailableFcnCount`, `NumberOfScans`/`NumScans` → implicit (no equivalent argument), `ExternalTriggerTimeout` → `DigitalTriggerTimeout`, `IsContinuous=true` → `start(d, "Continuous")` argument.
3. **Build the DataAcquisition object.** `d = daq("ni")`, set `d.Rate`, add channels with `addinput`/`addoutput`. Apply per-channel properties via the channel handle returned by `addinput`/`addoutput`.
4. **Wire triggers and clocks.** Use [`references/canonical-snippets.md`](references/canonical-snippets.md) §1 — load it when the script involves `addtrigger` or `addclock`. Argument order is `(d, type, role, trigSrc, trigDest)` — Source is 4th, Destination is 5th. **Verify:** the returned trigger object's `Source` and `Destination` fields show what you intended.
5. **Wire callbacks.** Use canonical snippets §2 — load it when the script needs `ScansAvailableFcn` or `ScansRequiredFcn`. Inside the callback, **always** pull data via `read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix")` — the `evt` argument is `matlabshared.asyncio.buffer.ElementsAvailableInfo` and exposes only `NumElementsAvailable`, no `Data`, no `TimeStamps`. **Strongly recommend** wiring `d.ErrorOccurredFcn = @(~,evt) fprintf("DAQ error: %s\n", evt.Error.message)` — without it, exceptions inside other callbacks are silently swallowed and the run "succeeds" while every fire throws. For strict ports where the legacy script had no `ErrorOccurred` listener, surface this trade-off to the user instead of silently adding the handler — let them opt in.
6. **Pick a state-sharing pattern (callbacks only).** If a callback needs to maintain state across fires (running counters, phase accumulator, latch flags), see [`references/callback-state-patterns.md`](references/callback-state-patterns.md) — load it any time a callback maintains state. Default: handle-class wrapper or nested function. Avoid `src.UserData.X = src.UserData.X + ...` field-mutation; it does not persist.
7. **Wire the lifecycle.** Use canonical snippets §3 — load it when blocking on completion. There is no `wait(d)` method on the modern object. For finite acquisitions, prefer `start(d, "Duration", seconds(N))` then `read` or a `Running` poll. For continuous, set a stop condition inside the callback (`if scansRead >= target; stop(src); end`) and poll `d.Running` from the caller.
8. **Run `verifyDataAcquisition` before live execution.** Script: [`scripts/verifyDataAcquisition.m`](scripts/verifyDataAcquisition.m). Catches the four highest-frequency silent gaps (missing `ErrorOccurredFcn`, `evt.Data` in callback source, `wait(d)` token, `UserData.X = UserData.X + ...` field mutation) by inspecting the live object and grepping the source file. Run via `mcp__matlab__run_matlab_file` if available, or copy into the user's project.
9. **Live verification.** Run a short version (e.g. 1–2 s instead of the user's full duration). Check that the script reaches `start` cleanly, that the callback fires at least once, and that no errors print from `ErrorOccurredFcn`. **Use `mcp__matlab__run_matlab_file` against a saved `.m` file**, not `mcp__matlab__evaluate_matlab_code` — the eval-string buffer runs in script mode and rejects local/nested function definitions, which Pattern 5 and most callback bodies require.
## Key Functions
| Function | Purpose | Toolbox | Available From |
|----------|---------|---------|----------------|
| `daq` | Create a `DataAcquisition` object (`d = daq("ni")`) | Data Acquisition Toolbox | R2020a |
| `addinput` | Add input channel (analog, counter, or digital) | Data Acquisition Toolbox | R2020a |
| `addoutput` | Add output channel | Data Acquisition Toolbox | R2020a |
| `addtrigger` | Add trigger connection: `addtrigger(d, type, role, trigSrc, trigDest)` | Data Acquisition Toolbox | R2020a |
| `addclock` | Add clock connection (similar signature) | Data Acquisition Toolbox | R2020a |
| `read` | Foreground acquire OR pull data inside `ScansAvailableFcn` | Data Acquisition Toolbox | R2020a |
| `write` | Write output samples (also from inside `ScansRequiredFcn`) | Data Acquisition Toolbox | R2020a |
| `preload` | Load initial output buffer before `start(d, "Continuous")`. **Output channels only.** | Data Acquisition Toolbox | R2020a |
| `start` | Begin background acquisition: `start(d)`, `start(d, "Continuous")`, `start(d, "Duration", seconds(N))` | Data Acquisition Toolbox | R2020a |
| `stop` | Stop a running acquisition | Data Acquisition Toolbox | R2020a |
| `flush` | Discard buffered scans before reading | Data Acquisition Toolbox | R2020a |
| `daqlist` | Enumerate available devices (replaces `daq.getDevices`) | Data Acquisition Toolbox | R2020a |
| `daqreset` | Reset DAQ subsystem (replaces `daq.reset`) | Data Acquisition Toolbox | R2020a |
Properties on `DataAcquisition`: `Rate`, `Running`, `NumScansAcquired`, `NumScansOutputByHardware`, `ScansAvailableFcn`, `ScansAvailableFcnCount`, `ScansRequiredFcn`, `ScansRequiredFcnCount`, `ErrorOccurredFcn`, `DigitalTriggerTimeout`, `UserData`.
## Patterns
The five canonical patterns below appear in full, with verified code, in [`references/canonical-snippets.md`](references/canonical-snippets.md). Inline below is the minimal recall snippet for each — enough to anchor the agent's memory under load. Load the reference for the full, runnable forms.
### Pattern 1: Add an external start trigger
```matlab
trg = addtrigger(d, "Digital", "StartTrigger", "External", "Dev1/PFI0");
trg.Condition = "RisingEdge";
d.DigitalTriggerTimeout = 30;
```
The 4th argument is the **Source** (`"External"` for an external signal). The 5th is the **Destination** (the device terminal). Reversing them is the most-frequent error in this domain. The trigger condition (`"RisingEdge"`, `"FallingEdge"`) is set on the **trigger object returned by `addtrigger`** (`trg.Condition`), **not** on the DataAcquisition object. There is no `d.DigitalTriggerCondition` property — inventing one passes static lint but errors at runtime.
### Pattern 2: ScansAvailableFcn body — pull data via `read`, never `evt.Data`
```matlab
d.ScansAvailableFcnCount = round(d.Rate * 0.5);
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
function onBlock(src)
[data, t] = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
plot(t, data); drawnow limitrate;
end
```
The `evt` argument carries only `NumElementsAvailable`; it has no `Data` or `TimeStamps`. Wiring `ErrorOccurredFcn` is strongly recommended — without it, callback exceptions are silently swallowed and the run "succeeds" while every fire throws. For strict ports of legacy scripts that did not have an `ErrorOccurred` listener, ask the user before adding one rather than inserting it silently.
### Pattern 3: Block until acquisition completes — there is no `wait(d)`
```matlab
start(d, "Duration", seconds(10));
while d.Running
pause(0.05);
end
```
`wait(d)` does not exist on `daq.interfaces.DataAcquisition`. Poll `d.Running`, or rely on `start(d, "Duration", ...)` + a stop condition inside the callback.
### Pattern 4: Continuous AO playback with auto-refill
```matlab
d = daq("ni");
d.Rate = 1000;
addoutput(d, "Dev1", "ao0", "Voltage");
d.ScansRequiredFcnCount = d.Rate;
d.ScansRequiredFcn = @(src, ~) write(src, generateNextBlock());
preload(d, generateNextBlock());
preload(d, generateNextBlock());
start(d, "Continuous");
```
`preload` is **output-only** — calling it on input-only setups errors. Two preloaded blocks before `start` give the buffer headroom for the first `ScansRequiredFcn` to fire.
### Pattern 5: Cross-callback state via nested function or handle class
```matlab
function runStreamingAcquisition()
d = daq("ni");
addinput(d, "Dev1", "ai0", "Voltage");
d.Rate = 1000;
d.ScansAvailableFcnCount = 200;
scansRead = 0;
target = d.Rate * 5;
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
start(d, "Continuous");
while d.Running
pause(0.05);
end
function onBlock(src)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
scansRead = scansRead + size(data, 1);
if scansRead >= target
stop(src);
end
end
end
```
Nested function captures `scansRead` by reference, so updates persist across fires. **Do not** use `src.UserData.X = src.UserData.X + ...` — that pattern does not persist; counters reset every fire and closed-loop control silently outputs zero forever. Full alternatives (handle class, full UserData rewrite) and their tradeoffs are in [`references/callback-state-patterns.md`](references/callback-state-patterns.md).
## Conventions
- **Strongly recommend** wiring `d.ErrorOccurredFcn` whenever any other `*Fcn` callback is set, since the listener swallows callback exceptions otherwise. For strict ports of legacy scripts that lacked an `ErrorOccurred` listener, surface the trade-off to the user rather than silently adding the handler — adding it is a defensible default but fidelity to the source is also defensible.
- **Always** pull data via `read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix")` inside `ScansAvailableFcn`. Never reach for `evt.Data` or `evt.TimeStamps`.
- **Always** verify the returned trigger object after `addtrigger` — confirm `Source` and `Destination` reflect intent.
- **Never** use `wait(d)`. Poll `d.Running` or use `start(d, "Duration", ...)`.
- **Never** mutate fields of `d.UserData` from inside a callback (`src.UserData.X = src.UserData.X + ...`). State must live in a closure-captured variable, a handle-class wrapper, or a whole-struct rewrite of `UserData`.
- **Never** call `preload` on an input-only `DataAcquisition`. It is output-only.
- **Prefer** `start(d, "Duration", seconds(N))` over `start(d, "NumScans", N)` for finite acquisition. `NumScans` is silently coerced or ignored.
- **Prefer** the modern function names: `daqlist` over `daq.getDevices`, `daqreset` over `daq.reset`, `daq("ni")` over `daq.createSession('ni')`.
## Common Mistakes
| Mistake | Why It's Wrong | Correct Approach |
|----------------------------------------------------------------|---------------------------------------------------------------------------------|---------------------------------------------------------------------------------|
| `addtrigger(d, "Digital", "StartTrigger", "Dev1/PFI0", "External")` | Source/Destination reversed. 4th arg is Source, 5th is Destination. | `addtrigger(d, "Digital", "StartTrigger", "External", "Dev1/PFI0")` |
| `plot(evt.TimeStamps, evt.Data)` inside `ScansAvailableFcn` | `evt` is `ElementsAvailableInfo`; only `NumElementsAvailable`. Throws silently. | `[data, t] = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix")` |
| `wait(d)` | No such method on `daq.interfaces.DataAcquisition`. Throws. | `while d.Running, pause(0.05); end` |
| `src.UserData.Counter = src.UserData.Counter + n` | Field mutation through `src.UserData` does not persist across callback fires. | Closure variable in nested function, or handle-class wrapper. See `callback-state-patterns.md`. |
| `preload(d, ...)` on a DAQ with only input channels | `preload` is output-only. | For inputs, just call `start(d, ...)`. No prepare/preload step needed. |
| `start(d, "NumScans", 1000)` | `NumScans` is ignored — emits warning. Buffer size determined by `preload` or `read`. | `start(d, "Duration", seconds(N))`, or rely on `preload` size. |
| `s.IsContinuous = true; s.startBackground();` | Both are session-API. Modern API has no `IsContinuous` property. | `start(d, "Continuous")` |
| `addlistener(d, 'DataAvailable', @cb)` | Listener events were renamed to `*Fcn` properties on the object. | `d.ScansAvailableFcn = @cb` |
| `s.queueOutputData(block)` | Session-API. Modern API uses `preload` (initial) and `write` (refill). | `preload(d, block)` before `start`; `write(d, block)` from `ScansRequiredFcn`. |
## References
- [`references/session-to-modern-mapping.md`](references/session-to-modern-mapping.md) — full rename table for every function and property that is commonly ported verbatim by mistake. Load whenever a session-API token appears in the legacy script.
- [`references/canonical-snippets.md`](references/canonical-snippets.md) — minimal, self-contained, runnable forms of the five patterns above. Load when composing a multi-feature script and you want a verified anchor.
- [`references/callback-state-patterns.md`](references/callback-state-patterns.md) — four state-sharing options (UserData / closure / handle-class / nested function), when to pick which, and the silent failure modes of the wrong choice. Load when any callback needs cross-fire state.
- [`scripts/verifyDataAcquisition.m`](scripts/verifyDataAcquisition.m) — static-checks a `DataAcquisition` object and its source script before live execution. Returns a structured report flagging the four highest-frequency silent gaps.
----
Copyright 2026 The MathWorks, Inc.
----
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!