Skip to content
Back to skills

Retention Time Mz Intensity Mapping

ASecurity

Use when you have processed LC-MS run data (feature table or peak detection

  • 16 stars
  • 0 votes
  • 0 copies
  • 3 views
  • Added September 12, 2026
ai-agentsgoapiperformance

Works with

  • cli
  • api

Security analysis

A100/100

Scanned September 12, 2026

npx -y skills add HolobiomicsLab/asb-skill-collections --skill retention-time-mz-intensity-mapping --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Retention Time Mz Intensity Mapping?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Retention Time Mz Intensity Mapping
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/holobiomicslab-retention-time-mz-intensity-mapping/badge)](https://www.skillsdirectory.com/skills/holobiomicslab-retention-time-mz-intensity-mapping)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: retention-time-mz-intensity-mapping
description: Use when you have processed LC-MS run data (feature table or peak detection
  output) containing internal standard identifications with retention times, m/z values,
  and intensity measurements across multiple samples, and you need to rapidly detect
  instrumental drift, retention time shifts, or.
license: CC-BY-4.0
metadata:
  edam_operation: http://edamontology.org/operation_3441
  edam_topics:
  - http://edamontology.org/topic_3520
  - http://edamontology.org/topic_0091
  tools:
  - Plotly
  - MSConvert
  - MS-DIAL
  techniques:
  - LC-MS
  license_tier: open
  provenance_tier: literature
derived_from:
- doi: 10.1021/acs.analchem.4c00786
  title: Rapid QC-MS
evidence_spans: []
claims: []
provenance:
  collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
  assembled_by: scripts/collect_metabolomics_collection.py
  sources:
  - build: coll_rapid_qc_ms_cq
    doi: 10.1021/acs.analchem.4c00786
    title: Rapid QC-MS
  dedup_kept_from: coll_rapid_qc_ms_cq
schema_version: 0.2.0
attribution:
  generator: AgenticScienceBuilder
  original_doi: 10.1021/acs.analchem.4c00786
  all_source_dois:
  - 10.1021/acs.analchem.4c00786
  zenodo_doi: 10.5281/zenodo.20794027
  curators: []
  promoter: Louis-Félix Nothias
  sponsor: CNRS & Université Côte d'Azur
---

# retention-time-mz-intensity-mapping

## Summary

Create an interactive multi-dimensional visualization of internal standard quality metrics (retention time, m/z, and intensity) across LC-MS samples to monitor instrumental performance and identify drift or failures during data acquisition. This skill is essential for real-time QC assessment in untargeted metabolomics workflows.

## When to use

Apply this skill when you have processed LC-MS run data (feature table or peak detection output) containing internal standard identifications with retention times, m/z values, and intensity measurements across multiple samples, and you need to rapidly detect instrumental drift, retention time shifts, or intensity degradation that indicate QC failure.

## When NOT to use

- Input is raw vendor format data (.raw, .d, .ms) — must first convert to mzML using MSConvert and process with MS-DIAL or equivalent peak detection
- Internal standards have not yet been identified or annotated in the feature table
- Goal is to visualize all metabolic features, not specifically internal standards — use general feature heatmap or chromatogram instead

## Inputs

- processed LC-MS feature table (CSV or tabular format) with internal standard peak identifications
- internal standard reference m/z values and retention time windows
- peak intensity measurements across all samples
- sample metadata (sample name, acquisition order, date)

## Outputs

- interactive HTML visualization (Plotly-based dashboard)
- static image export (PNG or PDF) of retention-time-mz-intensity plot
- visualization dataset with hover tooltip data (sample name, RT, m/z, intensity)

## How to apply

Load the processed LC-MS feature table or peak detection output and filter or subset the data to isolate internal standard peaks by matching known m/z and retention time windows. Construct an interactive plot using Plotly or equivalent framework with retention time on the x-axis, m/z on the y-axis, and intensity encoded as point size or color, grouping or faceting by sample identity. Implement interactive hover tooltips that display sample name, retention time, m/z, and intensity for each internal standard measurement to enable rapid diagnosis of anomalies. The multi-dimensional encoding allows simultaneous monitoring of three critical QC metrics; deviations in any dimension (e.g., retention time shift >0.5 min, intensity drop >30%, or unexpected m/z clustering) signal instrumental issues requiring intervention.

## Related tools

- **Plotly** (interactive plotting library for constructing multi-dimensional retention-time–m/z–intensity scatter plots with hover tooltips and sample grouping)
- **MSConvert** (prerequisite vendor format data conversion to mzML before peak detection and internal standard filtering) — https://proteowizard.sourceforge.io/tools/msconvert.html
- **MS-DIAL** (upstream peak detection and internal standard identification to produce feature table input) — http://prime.psc.riken.jp/compms/msdial/main.html

## Evaluation signals

- Hover tooltips correctly display all four dimensions (sample name, retention time, m/z, intensity) without truncation or missing values
- Sample grouping or faceting accurately segregates internal standard measurements by sample identity; no cross-contamination or mislabeling
- Retention time values fall within expected reference window (e.g., ±0.3–0.5 min of expected RT) for all samples; outliers are visually distinct
- Intensity values show expected consistency across replicates or technical replicates; intensity trends (e.g., gradual decline across run order) are visible and interpretable
- Interactive features (zoom, pan, hover, filtering by sample) respond smoothly and preserve data integrity; exported HTML or static image maintains visual fidelity

## Limitations

- Skill is specific to Rapid QC-MS workflow and depends on prior MS-DIAL peak detection; performance degrades if internal standards are not reliably identified or if peak detection has high false-positive rate
- Visualization assumes m/z and retention time measurements are accurate and that internal standard reference windows are correctly specified; misaligned or outdated reference data will produce misleading plots
- Interactive dashboard requires Plotly Dash and web browser (or Jupyter environment); deployment on Windows with MSConvert and MS-DIAL dependencies is the primary tested configuration; MacOS users can view results but cannot run acquisition pipeline
- Real-time visualization during instrument acquisition requires continuous file system monitoring (Watchdog); interruptions or file locks will delay or block updates

## Evidence

- [other] Construct an interactive plot (using Plotly or similar framework) with retention time on the x-axis, m/z on the y-axis, and intensity encoded as point size or color, with sample identity as a grouping or faceting dimension.: "Construct an interactive plot (using Plotly or similar framework) with retention time on the x-axis, m/z on the y-axis, and intensity encoded as point size or color, with sample identity as a"
- [other] Implement interactive hover tooltips displaying sample name, retention time, m/z, and intensity for each internal standard measurement.: "Implement interactive hover tooltips displaying sample name, retention time, m/z, and intensity for each internal standard measurement."
- [readme] Interactive data visualization of internal standard retention time, m/z, and intensity across samples: "Interactive data visualization of internal standard retention time, _m/z_, and intensity across samples"
- [other] Load processed LC-MS run data (feature table or peak detection output) containing internal standard identifications, retention times, m/z values, and intensity measurements across samples.: "Load processed LC-MS run data (feature table or peak detection output) containing internal standard identifications, retention times, m/z values, and intensity measurements across samples."
- [other] Filter or subset data to isolate internal standard peaks by matching known m/z and retention time windows.: "Filter or subset data to isolate internal standard peaks by matching known m/z and retention time windows."

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in ai-agents →

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.