Skip to content
Back to skills

Precursor Ion Isolation Windowing

ASecurity

Use when processing SWATH-MS (Sequential Windowed Acquisition of all

  • 16 stars
  • 0 votes
  • 0 copies
  • 4 views
  • Added September 12, 2026
ai-agentsgogit

Works with

  • cursor

Security analysis

A100/100

Scanned September 12, 2026

npx -y skills add HolobiomicsLab/asb-skill-collections --skill precursor-ion-isolation-windowing --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Precursor Ion Isolation Windowing?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Precursor Ion Isolation Windowing
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/holobiomicslab-precursor-ion-isolation-windowing/badge)](https://www.skillsdirectory.com/skills/holobiomicslab-precursor-ion-isolation-windowing)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: precursor-ion-isolation-windowing
description: Use when processing SWATH-MS (Sequential Windowed Acquisition of all
  Theoretical Mass-spectra) raw data files (mzML or vendor format) for untargeted
  metabolomics, specifically before attempting to deconvolute overlapping MS/MS spectra.
license: CC-BY-4.0
metadata:
  edam_operation: http://edamontology.org/operation_3633
  edam_topics:
  - http://edamontology.org/topic_0121
  - http://edamontology.org/topic_3520
  tools:
  - DecoMetDIA
  techniques:
  - LC-MS
  license_tier: open
  tool_license:
    tier: noncommercial
    requires_ack: true
    ref: CC-BY-NC-ND-4.0
    url: ZhuMSLab/DecoMetDIA
  provenance_tier: literature
derived_from:
- doi: 10.1021/acs.analchem.9b02655
  title: DecoMetDIA
evidence_spans:
- DecoMetDIA was developed to process SWATH-MS based data for metabolomics.
claims: []
provenance:
  collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
  assembled_by: scripts/collect_metabolomics_collection.py
  sources:
  - build: coll_decometdia_cq
    doi: 10.1021/acs.analchem.9b02655
    title: DecoMetDIA
  dedup_kept_from: coll_decometdia_cq
schema_version: 0.2.0
attribution:
  generator: AgenticScienceBuilder
  original_doi: 10.1021/acs.analchem.9b02655
  all_source_dois:
  - 10.1021/acs.analchem.9b02655
  zenodo_doi: 10.5281/zenodo.20794027
  curators: []
  promoter: Louis-Félix Nothias
  sponsor: CNRS & Université Côte d'Azur
---

# precursor-ion-isolation-windowing

## Summary

Grouping co-eluting fragment spectra from SWATH-MS data by precursor m/z and retention time windows to enable downstream spectral deconvolution. This step isolates multiplexed MS/MS spectra into manageable subsets for accurate component spectrum separation.

## When to use

Apply this skill when processing SWATH-MS (Sequential Windowed Acquisition of all Theoretical Mass-spectra) raw data files (mzML or vendor format) for untargeted metabolomics, specifically before attempting to deconvolute overlapping MS/MS spectra. Use it when your acquisition strategy has multiplexed many precursor ions into single isolation windows, resulting in mixed fragment spectra that require separation.

## When NOT to use

- Input is already targeted MS/MS data (single precursor per isolation) rather than multiplexed SWATH acquisition.
- Fragment spectra are already deconvoluted or pre-processed by vendor software; re-windowing may introduce artifacts.
- Data is from untargeted methods other than SWATH-MS (e.g., full-scan DIA without defined precursor windows) where precursor-window metadata may not be available or applicable.

## Inputs

- SWATH-MS raw data files (mzML format or vendor format)
- Instrument acquisition method metadata (precursor m/z window definitions, retention time windows)

## Outputs

- Grouped fragment spectra sets binned by precursor m/z and retention time window
- Intermediate spectral dataset ready for multiplexed spectrum decomposition

## How to apply

Load SWATH-MS raw data into DecoMetDIA and define precursor ion isolation windows based on the instrument's acquisition method (typically 25 Da or instrument-specific widths). Apply retention time windowing to group fragment spectra that co-elute within a defined time window (typically 0.5–2 min depending on chromatographic resolution). This pre-processing step reduces spectral complexity and focuses the subsequent deconvolution algorithm on a coherent set of fragments expected to arise from precursors within that m/z and retention time frame. The rationale is that precursor ions in a narrow m/z window with overlapping retention times are more likely to produce overlapping fragments; grouping them separately ensures the deconvolution algorithm can effectively separate individual component spectra without interference from distant precursors.

## Related tools

- **DecoMetDIA** (R package that implements precursor ion isolation and retention time windowing as a preprocessing step before spectral deconvolution of SWATH-MS data) — https://github.com/ZhuMSLab/DecoMetDIA

## Examples

```
devtools::install_github("ZhuMSLab/DecoMetDIA"); library(DecoMetDIA); # Then apply windowing via DecoMetDIA's preprocessing pipeline with m/z isolation and RT grouping before deconvolution
```

## Evaluation signals

- Verify that fragment spectra within each window have precursor m/z values within ±tolerance (e.g., 25 Da) of the window center.
- Check that retention times of grouped spectra cluster within the defined time window (e.g., all within 0.5–2 min).
- Confirm that the windowed groupings preserve co-eluting ions (similar retention times) while excluding distant precursors, reducing spectral overlap complexity.
- Validate post-deconvolution that component spectra within each window have consistent and interpretable mass differences and intensity distributions.
- Compare deconvolution quality metrics (peak counts, mass accuracy, signal-to-noise) before and after windowing to ensure windowing improves separation without loss of information.

## Limitations

- Windowing parameters (m/z width, retention time width) must match the SWATH-MS instrument configuration; mismatched parameters may either lose precursors or retain too much spectral noise.
- Compounds with very similar retention times but distant m/z values may be incorrectly grouped or separated depending on window size, potentially missing or creating false deconvoluted spectra.
- Retention time resolution depends on chromatographic method; high-resolution separations permit tighter time windows, while low-resolution methods require wider windows and may introduce more spectral mixing.

## Evidence

- [other] Apply precursor ion isolation and retention time windowing to group co-eluting fragment spectra: "Apply precursor ion isolation and retention time windowing to group co-eluting fragment spectra."
- [readme] DecoMetDIA was developed to process SWATH-MS based data for metabolomics: "DecoMetDIA was developed to process SWATH-MS based data for metabolomics."
- [other] Load SWATH-MS raw data files (mzML or vendor format) into DecoMetDIA: "Load SWATH-MS raw data files (mzML or vendor format) into DecoMetDIA."

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in ai-agents →

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.