Skip to content
Back to skills

Mass Spectrum Peak Detection

ASecurity

Use when you have raw or processed MS spectrum data (mz/intensity pairs)

  • 16 stars
  • 0 votes
  • 0 copies
  • 3 views
  • Added September 12, 2026
ai-agentsgogitapidatabaseperformance

Works with

  • api

Security analysis

A100/100

Scanned September 12, 2026

npx -y skills add HolobiomicsLab/asb-skill-collections --skill mass-spectrum-peak-detection --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Mass Spectrum Peak Detection?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Mass Spectrum Peak Detection
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/holobiomicslab-mass-spectrum-peak-detection/badge)](https://www.skillsdirectory.com/skills/holobiomicslab-mass-spectrum-peak-detection)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: mass-spectrum-peak-detection
description: Use when you have raw or processed MS spectrum data (mz/intensity pairs)
  from direct infusion MS (DI-MS), ASAP-MS, or other high-throughput ambient ionization
  methods, and need to identify which m/z signals represent true peaks of interest
  rather than noise or baseline drift.
license: CC-BY-4.0
metadata:
  edam_operation: http://edamontology.org/operation_3215
  edam_topics:
  - http://edamontology.org/topic_0121
  - http://edamontology.org/topic_3520
  tools:
  - RapidMass
  - DI-MS
  - ASAP-MS
  techniques:
  - direct-infusion-MS
  license_tier: restricted
  provenance_tier: literature
derived_from:
- doi: 10.1021/acs.analchem.4c05062
  title: RapidMass
evidence_spans:
- We have developed a versatile software platform, RapidMass.
- We have developed a versatile software platform, RapidMass
- supports data from multiple instruments, including DI-MS and ASAP-MS
claims: []
provenance:
  collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
  assembled_by: scripts/collect_metabolomics_collection.py
  sources:
  - build: coll_rapidmass_cq
    doi: 10.1021/acs.analchem.4c05062
    title: RapidMass
  dedup_kept_from: coll_rapidmass_cq
schema_version: 0.2.0
attribution:
  generator: AgenticScienceBuilder
  original_doi: 10.1021/acs.analchem.4c05062
  all_source_dois:
  - 10.1021/acs.analchem.4c05062
  zenodo_doi: 10.5281/zenodo.20794027
  curators: []
  promoter: Louis-Félix Nothias
  sponsor: CNRS & Université Côte d'Azur
---

# mass-spectrum-peak-detection

> **License: restricted** — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->
## Summary

Automatic identification of peaks of interest from raw or processed mass spectrometry spectra via algorithmic detection and intensity-based ranking. This skill extracts structured peak annotations (m/z, intensity, confidence scores) from unprocessed spectral data to enable downstream species authentication and sample classification.

## When to use

Apply this skill when you have raw or processed MS spectrum data (mz/intensity pairs) from direct infusion MS (DI-MS), ASAP-MS, or other high-throughput ambient ionization methods, and need to identify which m/z signals represent true peaks of interest rather than noise or baseline drift. Use it as the first analytical step before database scoring or peak annotation.

## When NOT to use

- Input is already a curated feature table or peak list with pre-assigned identities — re-detection would be redundant.
- Spectrum data is severely corrupted, contains extreme instrument artifacts, or lacks sufficient dynamic range to distinguish signal from noise.
- The analysis goal is to perform database matching without intermediate peak annotation — some workflows may skip explicit peak detection.

## Inputs

- raw MS spectrum data (mz/intensity pairs)
- processed MS spectrum data (mz/intensity pairs)
- data from DI-MS, ASAP-MS, or ambient ionization MS instruments

## Outputs

- peak identifier table
- m/z values for detected peaks
- intensity measurements
- confidence scores per peak
- annotated peak list with structured metadata

## How to apply

Load raw or processed MS spectrum data as mz/intensity pairs from the input file. Apply RapidMass's automatic peak detection algorithm to identify peaks of interest from the full spectrum. The algorithm ranks peaks by intensity and m/z values to distinguish genuine signals from background. Assign labels and confidence scores to each detected peak based on its intensity ranking relative to the overall spectrum distribution. Aggregate results into a structured output table with peak identifiers, m/z values, intensity measurements, and confidence scores. The detection rationale is grounded in intensity thresholding and m/z-based filtering to isolate species-characteristic signals from instrument noise.

## Related tools

- **RapidMass** (Provides the automatic peak detection algorithm and integrated workflow for loading spectra, detecting peaks, and generating annotated output tables with m/z, intensity, and confidence scores.) — https://github.com/Katherine00689/RapidMass
- **DI-MS** (Direct infusion mass spectrometry instrument supported as a data source for peak detection.)
- **ASAP-MS** (Ambient ionization mass spectrometry instrument supported as a data source for peak detection.)

## Evaluation signals

- All detected peaks have valid m/z values within the expected mass range for the instrument and sample type.
- Confidence scores are monotonically ranked by intensity; the highest-intensity peaks receive the highest confidence scores.
- Peak table schema is complete (peak_id, m/z, intensity, confidence_score) with no missing values.
- Detected peaks are reproducible across multiple runs on the same raw spectrum file (deterministic algorithm output).
- Visual inspection of detected peaks overlaid on the raw spectrum confirms they correspond to true local maxima and not baseline noise or instrument artifacts.

## Limitations

- Peak detection performance depends on the quality and dynamic range of the input spectrum; low-quality or heavily noisy spectra may yield false positives or miss low-abundance species-characteristic signals.
- The algorithm is optimized for high-throughput ambient ionization methods (DI-MS, ASAP-MS) and may require tuning or validation for other MS methodologies.
- Confidence scores are derived from intensity ranking and m/z-based heuristics; they do not incorporate external validation data such as tandem MS fragmentation patterns or database matching scores.

## Evidence

- [intro] The workflow and rationale for automatic peak detection.: "Load raw or processed MS spectrum data (mz/intensity pairs) from input file. 2. Apply RapidMass automatic peak detection algorithm to identify peaks of interest from the spectrum. 3. Assign labels"
- [readme] Software integration and scope of peak detection capability.: "the software provides automatic identification of interested MS peaks and supports data from multiple instruments, including DI-MS and ASAP-MS"
- [readme] User-facing output and accessibility of the peak detection feature.: "RapidMass features a user-friendly, visual interface, making it accessible to users without programming expertise"
- [readme] Supported instrument diversity for peak detection.: "Other high-throughput mass spectrometry such as ambient ionization mass spectrometry (AI-MS), laser desorption/ionization mass spectrometry (LDI-MS), and several modified MS methodologies can also be"

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in ai-agents →

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.