Installs into .claude/skills of the current project.
Sponsors
SSkills DirectorySkills Directory
Is that skill safe to install?
SSkills DirectorySkills Directory
Know which skills are safe — weekly.
Are you the author of Low Resolution Mass Spectra Library Matching?
Add the live security badge to your README. It updates with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-low-resolution-mass-spectra-library-matching-asb-skill-collections)
---
name: low-resolution-mass-spectra-library-matching
description: Use when when processing low-resolution GC-MS data in NetCDF format where
you have already performed retention-index calibration and peak deconvolution, and
you need to assign compound identities by comparing experimental mass spectra to
a curated reference library such as PNNLMetV20191015.MSL.
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3632
edam_topics:
- http://edamontology.org/topic_0769
- http://edamontology.org/topic_3520
tools:
- Docker
- CoreMS
- pandas
- numpy
techniques:
- GC-MS
license_tier: open
provenance_tier: literature
derived_from:
- doi: 10.5281/zenodo.14009575
title: corems
evidence_spans:
- from corems.encapsulation.factory.parameters import MSParameters
- CoreMS [section=results; evidence='from corems.encapsulation.factory.parameters
import MSParameters']
- import pandas as pd
- pandas [section=results; evidence='import pandas as pd']
- import numpy as np
- numpy [section=results; evidence='import numpy as np']
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_corems
doi: 10.5281/zenodo.14009575
title: corems
dedup_kept_from: coll_corems
schema_version: 0.2.0
attribution:
generator: AgenticScienceBuilder
original_doi: 10.5281/zenodo.14009575
all_source_dois:
- 10.5281/zenodo.14009575
zenodo_doi: 10.5281/zenodo.20794027
curators: []
promoter: Louis-Félix Nothias
sponsor: CNRS & Université Côte d'Azur
---
# low-resolution-mass-spectra-library-matching
## Summary
Identify unknown compounds in low-resolution GC-MS data by matching extracted mass spectra against a reference spectral library using cosine similarity and retention-index proximity scoring. This skill enables automated compound annotation when high-resolution mass accuracy is unavailable.
## When to use
When processing low-resolution GC-MS data in NetCDF format where you have already performed retention-index calibration and peak deconvolution, and you need to assign compound identities by comparing experimental mass spectra to a curated reference library such as PNNLMetV20191015.MSL.
## When NOT to use
- Input spectra are high-resolution (e.g., Orbitrap, FT-ICR) — use molecular formula assignment instead of spectral library matching.
- Reference library is absent or incompatible with your instrument or ionization mode.
- Peak deconvolution has not been performed; overlapping peaks will produce unreliable spectra and false matches.
## Inputs
- Raw GC-MS data in NetCDF format (ANDI-MS .cdf file)
- Calibrated retention indices for each detected peak
- Low-resolution mass spectra extracted from deconvolved peaks
- Reference spectral library (e.g., PNNLMetV20191015.MSL, SQLite or file-based format)
## Outputs
- Compound identification table (CSV or HDF5) with columns: m/z, retention index, compound name, CAS number, spectral match score, match rank
- Annotated mass spectrum objects with matched library entry metadata
- Match quality metrics (cosine similarity score, RI difference)
## How to apply
Extract the low-resolution mass spectrum from each detected chromatographic peak after baseline subtraction and peak deconvolution. Perform LowResMassSpectralMatch against a reference spectral library (e.g., PNNLMetV20191015.MSL), scoring each candidate match using cosine similarity of fragment ion patterns combined with retention-index proximity to the experimental peak's calibrated RI. Rank matches by combined score and retain the top candidate(s), filtering by a cosine similarity threshold (typically > 0.7) and RI match tolerance. Aggregate results into a structured table recording compound name, CAS number, retention index, spectral match score, and match rank for downstream validation and reporting.
## Related tools
- **CoreMS** (Provides LowResMassSpectralMatch class, retention-index calibration (get_rt_ri_pairs), and data I/O (ReadAndiNetCDF, CSV/HDF5 export)) — https://github.com/EMSL-Computing/CoreMS
- **pandas** (Aggregates and structures match results into tables for export and downstream analysis)
- **numpy** (Underlying numerical operations for cosine similarity calculation and score aggregation)
- **Docker** (Containerizes CoreMS with all dependencies for reproducible execution across platforms)
## Examples
```
from corems.data_structure.raw_data import ReadAndiNetCDF
from corems.encapsulation.factory.parameters import MSParameters
raw_data = ReadAndiNetCDF('sample.cdf')
raw_data.apply_gaussian_smoothing()
for spectrum in raw_data:
matches = spectrum.LowResMassSpectralMatch('PNNLMetV20191015.MSL')
print(f"Top match: {matches[0]['compound_name']} (score={matches[0]['cosine_similarity']})")
```
## Evaluation signals
- All peaks in the input dataset receive a match result (coverage check); verify no peaks are skipped due to missing or malformed spectra.
- Cosine similarity scores for top matches fall within the expected range (typically 0.5–1.0); verify no erroneous scores outside [0, 1].
- Retention-index differences between experimental and matched library entries are within the configured tolerance (e.g., ±100 RI units for GC-MS); check RI_difference column against tolerance threshold.
- Compound names, CAS numbers, and metadata fields are populated correctly and match the reference library format; spot-check a sample of rows for accuracy and against known standards if available.
- Output table schema matches expected columns (m/z, retention index, compound name, CAS number, spectral match score, match rank) and data types are consistent.
## Limitations
- Low-resolution mass spectra contain limited fragmentation detail; matches may be ambiguous or incorrect for structural isomers or compounds with very similar spectra.
- Spectral library coverage is incomplete; novel or rare compounds absent from the reference library will fail to match or produce low-confidence matches.
- Retention-index calibration quality directly affects match fidelity; poor RI calibration or uncalibrated data will increase false matches and false negatives.
- Cosine similarity alone does not account for instrument-specific ionization efficiency or peak intensity variations; preprocessing (normalization, baseline subtraction) affects reproducibility.
- Reference library may contain outdated, redundant, or incorrect entries; matches should be validated against independent confirmation methods (e.g., standards, GC-retention time databases, literature).
## Evidence
- [other] Extract low-resolution mass spectra from each peak and perform LowResMassSpectralMatch against the PNNLMetV20191015.MSL spectral library, scoring matches by cosine similarity and retention-index proximity.: "Extract low-resolution mass spectra from each peak and perform LowResMassSpectralMatch against the PNNLMetV20191015.MSL spectral library, scoring matches by cosine similarity and retention-index"
- [other] Load raw GC-MS data in NetCDF format using ReadAndiNetCDF, parsing instrument parameters and chromatographic signals. Apply GC_RI_Calibration to align retention times against reference alkane standards and compute retention indices for each detected peak.: "Load raw GC-MS data in NetCDF format using ReadAndiNetCDF, parsing instrument parameters and chromatographic signals. Apply GC_RI_Calibration to align retention times against reference alkane"
- [other] Aggregate results into a structured table with compound name, CAS number, retention index, spectral match score, and match rank.: "Aggregate results into a structured table with compound name, CAS number, retention index, spectral match score, and match rank."
- [readme] Automatic molecular match algorithm with all spectral similarity methods: "Automatic molecular match algorithm with all spectral similarity methods"
- [readme] ANDI NetCDF for GC-MS (.cdf): "ANDI NetCDF for GC-MS (.cdf)"