Skip to content
Back to skills

Chromatographic Peak Processing

ASecurity

Use when after peak detection when you have a table of detected peaks

  • 16 stars
  • 0 votes
  • 0 copies
  • 2 views
  • Added September 12, 2026
ai-agentsgogitdatabaseperformance

Security analysis

A100/100

Scanned September 12, 2026

npx -y skills add HolobiomicsLab/asb-skill-collections --skill chromatographic-peak-processing --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Chromatographic Peak Processing?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Chromatographic Peak Processing
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/holobiomicslab-chromatographic-peak-processing/badge)](https://www.skillsdirectory.com/skills/holobiomicslab-chromatographic-peak-processing)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: chromatographic-peak-processing
description: Use when after peak detection when you have a table of detected peaks
  with m/z values and retention times from LC/HRMS data, and you observe systematic
  m/z drift across a batch or population-scale study (n > 500 samples).
license: CC-BY-4.0
metadata:
  edam_operation: http://edamontology.org/operation_3632
  edam_topics:
  - http://edamontology.org/topic_0091
  - http://edamontology.org/topic_3370
  tools:
  - IDSL.IPA
  - R
  - RnetCDF
  techniques:
  - mass-spectrometry
  license_tier: restricted
  provenance_tier: literature
derived_from:
- doi: 10.1021/acs.jproteome.2c00120
  title: IDSL.IPA
evidence_spans:
- '**Intrinsic Peak Analysis (IPA)** by the [**Integrated Data Science Laboratory
  for Metabolomics and Exposomics (IDSL.ME)**](https://www.idsl.me) is a light-weight
  R package'
- light-weight R package
claims: []
provenance:
  collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
  assembled_by: scripts/collect_metabolomics_collection.py
  sources:
  - build: coll_idsl_ipa_cq
    doi: 10.1021/acs.jproteome.2c00120
    title: IDSL.IPA
  dedup_kept_from: coll_idsl_ipa_cq
schema_version: 0.2.0
attribution:
  generator: AgenticScienceBuilder
  original_doi: 10.1021/acs.jproteome.2c00120
  all_source_dois:
  - 10.1021/acs.jproteome.2c00120
  zenodo_doi: 10.5281/zenodo.20794027
  curators: []
  promoter: Louis-Félix Nothias
  sponsor: CNRS & Université Côte d'Azur
---

# Reconstruct the recursive mass correction stage

> **License: restricted** — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->
## Summary

Recursive mass correction refines m/z accuracy of detected LC/HRMS peaks by recalibrating against internal reference standards or lock masses. This is a critical post-detection stage in untargeted metabolomics workflows that improves downstream peak alignment and annotation reliability.

## When to use

Apply this skill after peak detection when you have a table of detected peaks with m/z values and retention times from LC/HRMS data, and you observe systematic m/z drift across a batch or population-scale study (n > 500 samples). It is essential before peak alignment and annotation steps to minimize mass calibration errors that propagate through downstream analysis.

## When NOT to use

- Input peaks are already aligned and annotated to a compound database—mass correction should precede annotation, not follow it.
- No internal reference standards or lock masses are available and mass drift is negligible (<1 ppm across the batch).
- Raw MS data has not yet undergone peak detection; mass correction operates on detected peaks, not raw spectra.

## Inputs

- Detected peaks table (Rdata or CSV format) with m/z values, retention times, and peak properties from prior peak detection
- Internal reference standards or lock mass list (m/z and expected retention time or m/z window)
- IPA parameter spreadsheet (IPA_parameters.xlsx) with mass correction and reference marker settings

## Outputs

- Corrected peak table (Rdata and CSV formats) with recalibrated m/z values
- Mass accuracy metrics (pre- and post-correction ppm error, residual mass distribution)
- Correction diagnostics (reference marker recovery, drift trajectory across batch)

## How to apply

Load the detected peaks table containing m/z values and peak properties (peak area, chromatographic descriptors, isotope ratios) generated by the peak detection stage. Apply IDSL.IPA's recursive mass correction algorithm, which iteratively recalibrates m/z values using endogenous or exogenous reference markers (lock masses) to eliminate systematic drift. Compare pre- and post-correction m/z accuracy metrics (e.g., mass error in ppm, deviation from theoretical m/z). Export the corrected peak table with updated m/z coordinates, ensuring mass error is reduced to specifications compatible with your downstream annotation tool (typically ≤5 ppm for high-resolution Orbitrap data). Evaluate correction success by examining the distribution of residual mass errors and checking that isotope mass differences (e.g., ¹²C/¹³C, ±1.003 Da) are preserved.

## Related tools

- **IDSL.IPA** (Primary R package implementing the recursive mass correction algorithm; processes mzXML, mzML, and netCDF LC/HRMS data and applies mass recalibration after peak detection) — https://github.com/idslme/IDSL.IPA
- **R** (Execution environment for IDSL.IPA; required for running the mass correction workflow)
- **RnetCDF** (Optional R package for reading netCDF/CDF mass spectrometry data formats before mass correction) — https://CRAN.R-project.org/package=RNetCDF

## Examples

```
library(IDSL.IPA)
IPA_workflow("path/to/IPA_parameters.xlsx")
```

## Evaluation signals

- Mass error (ppm) after correction is systematically lower and narrower in distribution than pre-correction values, typically within ±5 ppm for high-resolution instruments.
- Isotope mass differences (¹²C/¹³C pairs, nIsoPair, RCS metrics) remain intact post-correction, confirming no spurious m/z shifts were introduced.
- Reference marker peaks used for calibration show residual mass error < 1 ppm, indicating successful anchor recovery.
- Peak alignment statistics downstream of mass correction (e.g., retention time deviation, number of aligned features across samples) show improvement relative to uncorrected peaks.
- Corrected peak table structure and completeness match input format (same number of rows/columns, no NaN or Inf values introduced).

## Limitations

- Recursive mass correction requires reliable internal reference standards or lock masses; absence or poor quality of references will degrade correction fidelity.
- Algorithm assumes mass drift is systematic and smooth across the chromatographic run; non-linear or localized drift may not be fully corrected.
- Mass correction operates only on m/z dimension; retention time drift requires a separate retention time correction step using endogenous markers.
- No changelog or explicit version history is provided, limiting reproducibility tracking for specific algorithm revisions.
- Performance and parameter sensitivity for non-standard ionization modes (e.g., APCI, EI) are not explicitly documented.

## Evidence

- [other] recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using internal reference standards or lock masses: "Apply recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using internal reference standards or lock masses."
- [other] Load detected peaks table containing m/z values and peak properties from prior detection step: "Load detected peaks table containing m/z values and peak properties from prior detection step."
- [other] IDSL.IPA includes a recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy of detected peaks: "IDSL.IPA includes a recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy of detected peaks."
- [readme] algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation, recursive mass correction, retention time correction across multiple batches and peak annotation: "algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation, recursive mass correction, retention time correction across multiple batches and"
- [other] Compare pre- and post-correction m/z accuracy metrics and export final corrected peak dataset: "Compare pre- and post-correction m/z accuracy metrics and export final corrected peak dataset."

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in ai-agents →

Comments

Loading comments…

Newsletter