Open, SOTA-advancing research problems for Plenum — learned per-room thermal models, weather-aware predictive cycle planning, adaptive overshoot/deadband tuning, heat-pump shadow studies, and LLM/MCP self-explanation — each with the verified data asset behind it, the first three concrete in-repo steps, and a falsifiable numeric milestone. Load when asked "what could Plenum do that Flair/ecobee/research MPC can't", when starting an experiment on cycle-history data, or when scoping a learning/o...
Scanned 9/11/2026
Install to Claude Code
npx -y skills add dhruvb14/smart-thermostat-with-vents --skill plenum-research-frontier --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Plenum Research Frontier?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/dhruvb14-plenum-research-frontier)More formats (shields.io, HTML) on the badges page.
---
name: plenum-research-frontier
description: Open, SOTA-advancing research problems for Plenum — learned per-room thermal models, weather-aware predictive cycle planning, adaptive overshoot/deadband tuning, heat-pump shadow studies, and LLM/MCP self-explanation — each with the verified data asset behind it, the first three concrete in-repo steps, and a falsifiable numeric milestone. Load when asked "what could Plenum do that Flair/ecobee/research MPC can't", when starting an experiment on cycle-history data, or when scoping a learning/optimization feature. NOT a runbook for measuring today's behavior (plenum-diagnostics-and-tooling) or for how to run an experiment properly (plenum-research-methodology).
---
# Plenum research frontier
Open problems where Plenum could plausibly advance the state of the art in
residential HVAC zoning. Every item below is **candidate/open work — nothing
here is built, promised, or proven**. This skill owns the WHAT (which problems,
which data assets, which first steps, which success numbers). The DISCIPLINE —
how a hunch becomes an accepted result, what evidence bar applies — is owned by
**plenum-research-methodology**; read it before starting any item. The
measurement substrate (DB queries, ready-made analysis scripts) is owned by
**plenum-diagnostics-and-tooling**.
## When NOT to use this skill
| You want | Load instead |
|---|---|
| Numbers about what the system did (cycles, overshoot, duty cycle) | plenum-diagnostics-and-tooling |
| The evidence bar / idea lifecycle for an experiment | plenum-research-methodology |
| To actually change engine/guard code | plenum-change-control (gates), plenum-architecture-contract (invariants) |
| Domain theory (deadband, short-cycling, RC thermal models context) | hvac-zoning-reference |
| Where a config knob lives / its bounds | plenum-config-and-flags |
## Ground rules for all experiments (non-negotiable)
1. **Safety guards are one-way ratchets** (inferred rule from repo history — see
plenum-change-control). No experiment may weaken short-cycle protection
(`min_cycle_runtime_min` / `min_cycle_offtime_min`), the cooling lockout
(`cooling_lockout_below_f`), the airflow floor (`min_open_vents_fraction`),
the staleness/unavailability guards, or the `min_setpoint`/`max_setpoint`
envelope — even "temporarily, for data collection".
2. **The sandbox is Dev Mode, not a simulator.** Dev Mode runs the engine
normally — real sensor reads, real room selection, real vent-move
computation — but intercepts every outbound HA service call
(`climate.set_temperature`, `cover.open_cover`, `cover.close_cover`,
`cover.set_cover_position`, `cover.set_cover_tilt_position`,
`cover.toggle`) and logs it to `event_log` instead of sending it. There are
**no simulated cycles and no synthetic house model**: what you get is
*shadow mode* — the engine's would-be commands against the real house's real
trajectory, which itself is being driven by whatever is actually controlling
the HVAC. Mode semantics are owned by **plenum-run-and-operate**; the one
line that matters here: the engine gate is `system_enabled OR dev_mode`
(`scheduler.py:477`), so engines keep ticking under Dev Mode even with
System Off — only both-off stops ticking entirely.
Design experiments accordingly — Dev Mode gives you counterfactual command
logs, not counterfactual temperatures. (Re-verified 2026-09-01: the gate is
now `scheduler.py:624`, `get_enabled=lambda: self._system_enabled or
self._dev_mode` — same semantics, line moved.)
3. **Offline first.** Every item below starts with read-only analysis of
`app.db` (see plenum-run-and-operate for where it lives). Copy the DB out and
open it `mode=ro`, as the diagnostics scripts do.
4. **All stored temperatures are °F; deltas are °F deltas** (no −32). Model in
°F end-to-end; convert only at the write boundary if a result ever ships
(see plenum-architecture-contract for the #231 contract; the conversion
helpers live in `smart_vent/backend/units.py` — pre-2026-07-05 CLAUDE.md
copies said routes.py; corrected in PR #388 — if docs and repo disagree
again, the repo wins). Timestamps in the DB are naive UTC ISO strings.
5. **Anything that ships needs a UI control** (CLAUDE.md 100% rule) and clears
plenum-change-control. Advice-only outputs (a "suggested value" shown in the
UI) are a deliberately lower-risk shipping target than closed-loop control.
## The verified data substrate (originally 2026-07 v0.22.1, re-verified 2026-09-01 v0.35.0)
All verified by reading `smart_vent/backend/db.py` (SCHEMA, lines 43–322) and
the engine. This per-room, per-tick, actuation-annotated dataset is the asset
commercial products don't expose and research MPC testbeds have to build by
hand.
| Table | Columns that matter for research | Written by |
|---|---|---|
| `cycle_logs` | `started_at`, `ended_at`, `mode`, `ended_reason`, `thermostat_temp_at_start/_end`, `setpoint_at_start/_end`, `vents_at_start/_end`, **`outside_temp_at_start`**, **`outside_temp_at_end`**, `in_min_runtime_hold` | engine, cycle open/close (`cycle_engine.py` ~959 `insert_cycle_log`, ~1751 `close_cycle_log`) |
| `room_cycle_states` | per (cycle, room): `target_temp`, **`reached_at`**, **`vent_closed_at`**, `temp_at_start`, `temp_at_end`, `joined_at`, `role` (`'overflow'` rows are conditioning ballast — exclude from comfort analyses), plus Eco Mode's `requested_target`/`effective_target`/`eco_active` (Issue #404 — see the item-1 caveat below) | engine |
| `cycle_temp_samples` | **one row per active room per 60s tick**: `timestamp`, `room_temp`, `thermostat_temp`, `setpoint` (writer: `cycle_engine.py:1368`) | engine |
| `cycle_setpoint_history` | every setpoint command with `reason` | engine |
| `cycle_vent_events` | every vent `action` + `reason` with timestamp and `entity_id`/`room_id` | engine |
| `daily_thermostat_metrics` / `monthly_…` | `heating_seconds`, `cooling_seconds`, cycle counts by outcome, `avg_outside_temp_at_start/_end` | rollup jobs |
| `rooms` | the hand-tuned knobs to replace: `temp_offset`, `deadband_override`, `ambient_suppression_*` | user |
| `thermostat_configs` | `overshoot_delta` (default 2.0 °F), `deadband` (default 0.5 °F), the safety envelope fields | user |
| `event_log` | categorized narrative incl. Dev-Mode intercepted commands | event_logger |
Plus: metrics endpoints (`/api/metrics/thermostats/{id}/timeseries`,
`…/cycles-vs-outside-temp`, `…/overshoot-histogram`, `…/rooms` with
time-to-target — `routes.py` ~3107–3316), the diagnostics scripts
(`plenum-diagnostics-and-tooling/scripts/`: `cycle_report.py`,
`overshoot_stats.py`, `hvac_quality.py`), and the full REST surface as
auto-generated MCP tools (below).
**Data-hygiene note (resolved, Issue #394 — no longer a live caveat as of
2026-09-01):** an earlier version of this skill flagged that the only
production writer of `cycle_temp_samples` always passes a non-NULL `room_id`
while `db._degree_minutes_timeseries` filtered `s.room_id IS NULL`, which
would have meant the degree-minutes chart computed over nothing. Re-reading
`_degree_minutes_timeseries` (`db.py:2632`) confirms this was fixed: its
docstring now states the per-tick sampler writes one row per active room, all
carrying the same `thermostat_temp`/`setpoint` reading, so the query no
longer filters by `room_id` at all — it collapses a multi-room tick to one
row per `(cycle_id, timestamp)` with `MAX()` instead (legacy `room_id=NULL`
rows, if any exist from before #394, still work unchanged through the same
`MAX()`). `compute_overshoot_histogram` (`db.py:2716`) does still join on
`(s.room_id = rcs.room_id OR s.room_id IS NULL)`, but that is a documented,
intentional per-room fallback (Issue #290: use room-level samples when
present, thermostat-level only when a room produced none) — not the same bug
shape. Still worth a sanity query before building on either representation,
but treat it as routine verification, not a known-suspect gap:
`sqlite3 app.db "SELECT COUNT(*), SUM(room_id IS NULL) FROM cycle_temp_samples"`.
---
## Frontier item 1 — Learned per-room thermal response models (candidate)
Replace the two hand-tuned per-room fudge factors — `rooms.temp_offset` (born
from incident #86: post-closure drift blocked cycle termination) and
`thermostat_configs.overshoot_delta` — with models fitted from cycle history.
**Why current SOTA falls short.** Flair/Keen/ecobee zoning uses static per-room
offsets and fixed hysteresis; none learn per-room dynamics or expose the data to
let a user do it. Residential MPC research fits whole-house RC models on
purpose-built testbeds; per-room models with *vent actuation as the control
input* are rare because nobody logs per-room temperature trajectories aligned
with vent open/close events. Plenum does, every 60 seconds.
**Plenum's specific asset (verified above):** `cycle_temp_samples` per-tick
room trajectories + `room_cycle_states.reached_at`/`vent_closed_at` giving the
exact conditioning→coasting phase boundary per room + `cycle_vent_events` for
every vent move + `cycle_logs.outside_temp_at_start/_end` for the disturbance
term.
**First three steps in this repo:**
1. Write `scripts/response_rate.py` (this skill's dir, read-only, modeled on
`plenum-diagnostics-and-tooling/scripts/`): per-room conditioning-phase
response rate in °F/min vs outdoor temperature. Core query (schema-verified):
```sql
SELECT rcs.room_id, cl.mode,
(rcs.temp_at_end - rcs.temp_at_start) * 60.0 /
MAX(1,(julianday(COALESCE(rcs.reached_at, cl.ended_at))
- julianday(cl.started_at)) * 86400) AS f_per_min,
cl.outside_temp_at_start
FROM room_cycle_states rcs JOIN cycle_logs cl ON cl.id = rcs.cycle_id
WHERE cl.ended_at IS NOT NULL AND rcs.role != 'overflow'
AND rcs.temp_at_start IS NOT NULL AND rcs.temp_at_end IS NOT NULL;
```
Refine with per-tick slopes from `cycle_temp_samples` joined on
`(cycle_id, room_id)` restricted to `timestamp < reached_at`.
2. Write `scripts/drift_model.py`: post-closure drift per room — samples with
`timestamp > rcs.vent_closed_at`, plus `temp_at_end − target_temp` as the
terminal drift, regressed against `(outside_temp − room_temp)` and elapsed
minutes. Compare its predictions against the static `rooms.temp_offset`
baseline on held-out cycles (methodology: see plenum-research-methodology
for the split discipline).
3. Fit a 1R1C model per room offline (`dT/dt = k_hvac·u + k_env·(T_out − T)`,
`u` = vent-open indicator from `cycle_vent_events`), least squares over the
per-tick samples; evaluate both models on the same holdout.
**You have a result when:** the drift model predicts each room's temperature
10 minutes after `vent_closed_at` within **±0.5 °F RMSE on ≥50 held-out
(cycle, room) participations**, and beats the static-`temp_offset` predictor's
RMSE on the same holdout. Below that, the hand-tuned knob stays.
**Eco Mode caveat (shipped since this item was written — see `docs/eco-mode.md`):**
`room_cycle_states.target_temp` is now the room's **effective** target — after
Eco Mode's outdoor-temperature relaxation, when active (`eco_active = 1`,
Issue #404) — not necessarily the temperature the room was originally asked
for (`requested_target`). Fitting a response-rate or drift model straight off
`target_temp` on a home with Eco Mode on will conflate genuine per-room
thermal response with Eco's proportional setpoint drift. Either filter to
`eco_active = 0` for a first pass, or model against `requested_target` and
treat `effective_target − requested_target` as a known, already-explained
input rather than something to learn.
## Frontier item 2 — Weather-aware predictive cycle planning (candidate)
Extend the shipped ambient-drift heuristic (`docs/precool-presence.md`) from a
fixed threshold gate into a prediction: "will this room coast to target within
N minutes?" — and eventually plan cycles against known future targets.
**Why current SOTA falls short.** Commercial "smart recovery"/pre-cool uses
fixed or opaque lead times and is whole-house. Research MPC handles forecasts
but not per-room vent zoning on commodity hardware. Plenum's current heuristic
(verified: `cycle_engine.py:2056` `_ambient_suppression_eligible`, gate =
`outside ≥ target + min_differential`) is deliberately dumb — a 5 °F fixed
differential regardless of how fast this particular room actually drifts.
**Not superseded by Eco Mode.** Eco Mode (`docs/eco-mode.md`) also
shipped since this item was written and is also outdoor-temperature-driven,
but it solves a different problem: it *relaxes the target itself* by a static
proportional formula (no prediction, no per-room learning) so the HVAC works
less hard on extreme days. This item is about *predicting whether a room
will reach its unrelaxed target on ambient drift alone*, to decide whether to
run HVAC at all. The two are complementary, not redundant — a coast-time
predictor here could in principle also inform how aggressively Eco Mode's
ramp should be set, but that's future scope, not started.
**Plenum's specific asset:** the `schedules` table means future targets are
*known* (`days_of_week`, `start_time`, `end_time`, `target_temp`); item 1's
drift model gives per-room coast rates; `daily_thermostat_metrics.heating_seconds/
cooling_seconds` give the energy proxy to minimize; `/api/metrics/…/cycles-vs-outside-temp`
(`db.compute_cycles_vs_outside_temp`, db.py:2901) already correlates cycle cost
with weather.
**First three steps in this repo:**
1. `scripts/coast_replay.py`: for every historical presence/schedule-driven
cycle in `cycle_logs`, ask the item-1 drift model whether coasting would have
reached target within the presence holdover window; tally (a) conditioning
seconds that could have been skipped, (b) predicted comfort misses (>1 °F
beyond deadband). Pure offline replay — no engine changes.
2. If replay is favorable, prototype replacing the fixed
`ambient_suppression_min_differential` gate with predicted time-to-target in
`_ambient_suppression_eligible` — per-room opt-in flag, default off, additive
schema change only, full plenum-change-control pass (touches engine
decision logic).
3. Forecast ingestion (candidate, further out): read an HA `weather.*` /
forecast sensor via `ha_client.py` alongside the existing outside-temp
sensor, so the gate can use "outside temp in 60 min" instead of now.
Fail-safe like the current feature: unreadable forecast ⇒ behave exactly as
today.
**You have a result when:** replay over **≥30 days of real history** predicts
**≥10% reduction in total `heating_seconds + cooling_seconds`** (from
`daily_thermostat_metrics`) with **≤1 predicted comfort miss per week** (room
>1 °F beyond its effective deadband while coasting). If the drift model isn't
past its item-1 milestone, this item is blocked — don't start here.
## Frontier item 3 — Adaptive overshoot & deadband tuning inside the safety envelope (candidate)
`overshoot_delta` (default 2.0 °F) and `deadband` (default 0.5 °F) are static
per-thermostat guesses. The overshoot histogram
(`db.compute_overshoot_histogram`, db.py:2716, semantics replicated in
`overshoot_stats.py`) already measures how wrong they are; today a human closes
the loop by hand.
**Why current SOTA falls short.** ecobee's adaptive recovery is single-zone and
unexplainable; no commercial zoning product tunes per-thermostat hysteresis
from observed per-room overshoot, and none show their work.
**Plenum's specific asset:** the histogram (`db.compute_overshoot_histogram`,
db.py:2716) + `cycle_setpoint_history` (every setpoint command with `reason`)
+ `ended_reason` outcome buckets (`_ROLLUP_REASON_BUCKETS`, db.py:2140) + a
*hard* envelope to tune inside: `min_setpoint`/`max_setpoint` (validated
**40–100 °F** post-normalization — `routes.py` `_temp_range_error("Setpoints",
40, 100, unit)`, e.g. ~line 1683; the `.jules/sentinel.md` file this was
previously cited to was removed from the repo in #532 — the setpoint-bounds
lesson it recorded is preserved in `plenum-failure-archaeology`),
`min_cycle_runtime_min`/`min_cycle_offtime_min`, and `hvac_quality.py` as an
automated regression detector (exit 1 on red flags).
**First three steps in this repo:**
1. `scripts/suggest_overshoot.py`: per thermostat, recommend
`overshoot_delta` = e.g. the 80th-percentile observed overshoot from the
histogram data over the last N weeks, floored at the current deadband;
print current vs suggested with supporting cycle counts.
2. Surface it advice-only: a "suggested value" annotation next to
`overshoot_delta` on the Thermostats page (satisfies the UI rule; no control
authority; new read-only endpoint over the existing histogram query).
3. Closed-loop candidate (only after 1–2 prove out): a nightly job proposing a
bounded step (≤0.5 °F per week) applied **via the existing PUT
`/api/thermostats/...` route** so the write-boundary validation and logging
apply — never a direct DB write. Trial first in Dev Mode / on the advice-only
output; requires plenum-change-control review as an engine-adjacent change.
**You have a result when:** after adopting suggested values on a real system,
the overshoot-histogram mass in bins **≥2 °F drops by ≥50% over ≥40 subsequent
completed cycles**, while `timeout_count` does not rise and `hvac_quality.py`
still exits 0 (no new short cycles / oscillation). A comfort gain that trips a
safety flag is a failed result.
## Frontier item 4 — Heat pumps as a shadow-mode research problem (long-horizon candidate)
Heat pumps are explicitly unsupported (README.md:112, `docs/safety.md` top
blockquote, and the "Heat pumps are not supported, so there is no heating
lockout" comment inside the cooling-lockout block at `cycle_engine.py:~452`)
because reversing-valve and defrost semantics invalidate guards designed for
furnace+AC (the cooling lockout has no heating analog — see
plenum-architecture-contract's known-weak-points table). **Nothing in this
item weakens that fence.** Any code change here must clear the
plenum-change-control safety ratchet, and the docs' non-support line stays
until support is real (plenum-docs-and-writing owns that claim discipline).
**Why current SOTA falls short.** Vent zoning of ducted heat pumps is genuinely
open: variable-capacity compressors interact badly with vent-induced static
pressure, and no commercial vent product publishes a safety envelope for it.
**Plenum's specific asset:** Dev Mode (verified, `docs/system-modes.md`) makes
a *zero-actuation shadow study* possible on a real heat-pump home: the engine
runs its full decision logic and every would-be `climate.*`/`cover.*` command
lands in `event_log` — Plenum never touches the equipment.
**First three steps in this repo:**
1. Shadow deployment: run Plenum with **Dev Mode ON** in a heat-pump home
(rooms/sensors configured, vents mapped or fake `cover` helpers); collect
≥2 weeks of `event_log` + `cycle_logs` of would-be behavior while the OEM
thermostat actually runs the house.
2. Guard-by-guard failure analysis on that data: for each engine guard (mode
lock, cooling lockout `cycle_engine.py:~447`, min-runtime hold, ambient
reset), document what a reversing valve / defrost event would have done to
it. Deliverable: a `docs/`-style analysis note, not code.
3. Only then: a design proposal through plenum-change-control defining a
heat-pump-specific envelope (e.g. compressor-protective minimum runtimes,
defrost-window command blackouts) before any `models.py` change.
**You have a result when:** the shadow log over **≥14 days** shows the current
engine would have issued **zero** commands violating a written heat-pump
envelope — concretely: 0 would-be mode reversals within 30 min of a prior
opposite-mode command, 0 would-be cycles shorter than 10 min, 100% of would-be
setpoints inside `min_setpoint`/`max_setpoint`. Any violation is equally a
result: it documents exactly why the fence exists, with data.
## Frontier item 5 — LLM/MCP self-explanation and agent-assisted tuning (candidate)
**Plenum's specific asset (verified in `mcp_openapi.py` / `mcp_http.py`,
shipped 0.22.0 per issue #372/PR #375, port default 9099, `mcp_enabled`
toggle off by default):** the *entire* REST surface — rooms, schedules,
thermostat safety config, cycle and event logs, metrics — is auto-generated
into MCP tools from the OpenAPI spec (`mcp_openapi.build_tool_specs`), each
call dispatched back through the running routes over loopback, so agent
writes get the same validation and unit conversion as the UI. No commercial
zoning product exposes anything like this; "why did my HVAC do X last night?"
is unanswerable in Flair/ecobee. **Since this item was written, #373 (auth)
and #464 (OIDC) have both shipped** (`docs/auth.md`, `docs/mcp.md`): with
`require_auth` on (the default), every `/mcp` call needs a bearer token
scoped `read` / `write` / `destructive`, minted from the Settings page. This
doesn't change what's achievable here, but it changes step 3 below.
**First three steps in this repo:**
1. Build an explanation eval: 20 questions with DB-ground-truth answers drawn
from a real `app.db` ("why did the 2pm cycle end?" → `cycle_logs.ended_reason`
+ `cycle_setpoint_history.reason` + `cycle_vent_events`); attach Claude per
`docs/mcp.md` and grade tool-only answers.
2. If the agent flails from too many round-trips, add one read-only
"cycle bundle" endpoint aggregating `cycle_logs` + samples + setpoint
history + vent events for a `cycle_id` (the per-room samples endpoint at
`routes.py:2403` is the seed). Read-only ⇒ lowest change-control class, but
still needs `@docs`/`@response_schema` (spec-enforcement test) and becomes
an MCP tool automatically.
3. Agent-assisted tuning: agent proposes item-3 style config changes via the
existing PUT tools with a human approving each. #373 has since shipped, so
this is no longer blocked on a missing auth layer — mint a **`write`-scoped**
(not `destructive`) token for the agent so it cannot restart/restore/manage
tokens on its own, and keep the human approval step regardless: the risk
this item guards against is an agent making *unsupervised* control
changes, which scoped auth alone doesn't solve. Do not route an
autonomous loop around the human-approval step just because auth now
exists.
**You have a result when:** the agent answers **≥90% of the 20-question eval
correctly** (graded against the DB) using only MCP tools, with the transcript
as the explanation artifact. Stretch: same bar from a non-developer's phrasing
of the questions.
---
## Prioritization (one opinion, clearly labeled as such)
Item 1 is the keystone: items 2 and 3 consume its model, and it needs nothing
but a copied `app.db` and a few hundred logged cycles. Item 5 is independent
and cheap to attempt today. Item 4 is deliberately last — highest safety
stakes, longest horizon, and its first step requires access to a heat-pump
home. All numeric milestones above are proposed bars, not attained results.
## Provenance and maintenance
Facts originally verified against the repo at v0.22.1, 2026-07-05.
**Re-verified 2026-09-01 against v0.35.0 stable** (13 releases / ~100 commits
later) — every line number below was re-grepped and corrected where it had
drifted; the data-hygiene caveat, the MCP-auth framing, the heat-pump-fence
citations, and the `min_setpoint`/`max_setpoint` bound were substantively
wrong at the old date and are fixed above, not just renumbered. Re-verify
again before use, especially anything with a line number:
- Schema (tables/columns cited above): `grep -n "CREATE TABLE" smart_vent/backend/db.py` — SCHEMA block now at db.py lines 43–322 (grew from 42–247 with `eco_suspensions` and `mcp_tokens` tables, among others).
- Per-tick sample writer (only production writer, always non-NULL room_id): `grep -rn insert_cycle_temp_sample smart_vent/backend --include=*.py | grep -v tests` → `cycle_engine.py:1368` only (moved from :1098).
- Degree-minutes query: `_degree_minutes_timeseries` now at db.py:2632; per Issue #394 it no longer filters `s.room_id IS NULL` — see the data-hygiene note above. `compute_overshoot_histogram` (db.py:2716) does still use that join arm, intentionally (Issue #290).
- Hand-tuned knobs + defaults: `rooms.temp_offset` (db.py:55, was :50), `overshoot_delta REAL NOT NULL DEFAULT 2.0` (db.py:121, was :100), `deadband … DEFAULT 0.5` (db.py:119, was :98).
- Ambient-drift heuristic: `docs/precool-presence.md`; `_ambient_suppression_eligible` at `cycle_engine.py:2056` (moved from :1575).
- Dev Mode semantics (intercept + log, no simulation): `docs/system-modes.md`.
- Engine tick gate (`system_enabled OR dev_mode`): `scheduler.py:624` (moved from :477).
- Heat-pump fence: README.md:112 (moved from :108), `docs/safety.md` top blockquote, `cycle_engine.py:~452` comment inside the cooling-lockout block. `models.py:210` is stale — that line is now just the `default_temp` field comment and models.py carries no heat-pump text at all; don't cite it.
- Setpoint bounds: `min_setpoint`/`max_setpoint` are validated **40–100 °F** post-normalization (`routes.py` `_temp_range_error("Setpoints", 40, 100, unit)`, e.g. line 1683) — not 40–90 °F, which is the bound for `target_temp`/`default_temp`/`system_wide_temp` instead (`_temp_range_error(field, 40, 90, unit)`, several call sites). The `.jules/sentinel.md` file this was previously cited to no longer exists in the repo (removed by #532); the lesson it recorded is preserved in `plenum-failure-archaeology`.
- MCP: `mcp_http.py` (port/toggle/503), `mcp_openapi.py` (`build_tool_specs`), `docs/mcp.md`; shipped 0.22.0, port row in config 0.22.1. `mcp_enabled` is still off by default (`scheduler.py:62`, `db.get_system_setting(..., "mcp_enabled", "0")`). **Auth (#373) and OIDC (#464) have since shipped** — `require_auth` defaults to `true` (`config.yaml`), gating every `/mcp` request behind a scoped bearer token (`docs/auth.md`); the pre-2026-09 "MCP is unauthenticated" framing is gone.
- Metrics endpoints: `grep -n "@routes.get(\"/api/metrics/" smart_vent/backend/api/routes.py` — now ~lines 3107–3316 (moved from ~2023–2263); per-room samples endpoint at routes.py:2403 (moved from :1581).
- Diagnostics scripts: `ls .claude/skills/plenum-diagnostics-and-tooling/scripts/`.
- All SQL snippets in this file were executed against an in-memory DB built from the real SCHEMA string (2026-07-05) and re-checked by reading the current schema (2026-09-01); the columns item 1's query depends on (`room_cycle_states.target_temp/reached_at/vent_closed_at/temp_at_start/temp_at_end/role`, `cycle_logs.started_at/ended_at/outside_temp_at_start`) are unchanged. Still NOT run against a production `app.db`.
- 60s tick: `smart_vent/backend/scheduler.py` (`seconds=60` at lines 158/177, moved from ~133/152).
- Line numbers drift; re-grep rather than trust them after any engine/db change.
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.