Turbine Blade Cooling

ASecurity

Use when you must analyze the cooling flow required to protect a gas turbine blade row: compute the cooling effectiveness from the hot gas total temperature, the allowable blade metal temperature and the coolant supply temperature, convert it into the required coolant-to-gas mass flow fraction with a simplified energy balance, check the fraction against the practical bleed limit, and estimate the achievable metal temperature when film cooling lifts the effectiveness. Produces the effectivenes...

2 stars
0 votes
0 copies
0 views
Added 9/27/2026
ai-agentspythongo

Works with

claude code

Security Analysis

A100/100

Scanned 9/27/2026

Install to Claude Code

$npx -y skills add ashfordeOU/aero-agent-skills --skill turbine-blade-cooling --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Turbine Blade Cooling?

Add the live security badge to your README — it updates automatically with every re-scan.

Security grade badge for Turbine Blade Cooling
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/ashfordeou-turbine-blade-cooling/badge)](https://www.skillsdirectory.com/skills/ashfordeou-turbine-blade-cooling)

More formats (shields.io, HTML) on the badges page.

Download with Pro
Files
SKILL.md
---
name: turbine-blade-cooling
description: "Use when you must analyze the cooling flow required to protect a gas turbine blade row: compute the cooling effectiveness from the hot gas total temperature, the allowable blade metal temperature and the coolant supply temperature, convert it into the required coolant-to-gas mass flow fraction with a simplified energy balance, check the fraction against the practical bleed limit, and estimate the achievable metal temperature when film cooling lifts the effectiveness. Produces the effectiveness, coolant fraction, bleed-limit verdict, metal temperature and margin that gate hot section cooling design in the FAR-33 engine context. Trigger: turbine blade cooling, cooling effectiveness, coolant flow fraction, film cooling, allowable metal temperature, coolant supply temperature, bleed limit, hot section cooling."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
  - id: far-33
    reference-only: true
gated: false
domain: propulsion
pack: axial-compressor
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
  domain: propulsion
  subdomain: axial-compressor
  tags: [turbine-blade-cooling, cooling-effectiveness, coolant-flow-fraction, film-cooling, bleed-limit, allowable-metal-temperature, hot-section-cooling]
  version: 0.1.0
  author: Aero Agent Skills
---

# Turbine Blade Cooling (propulsion/axial-compressor/turbine-blade-cooling)

Use when the task is the heat-transfer side of a turbine blade row
design: how much cooling flow the hot section must bleed from the
compressor to hold the blade metal below its allowable temperature.
This leaf implements the standard cooling-effectiveness model in pure
Python, stdlib only. The baseline model is internal convection; an
optional film cooling term adds a fixed effectiveness gain at the
leading edge. It pairs with propulsion/axial-compressor/turbine-stage
for the aerodynamic design of the same blade row and with the
gas-turbine-cycle leaves for the cycle cost of the bleed flow.

## Domain quick reference

- Cooling effectiveness: phi = (T_gas - T_metal_allow) / (T_gas -
  T_coolant). The metal temperature is held a fraction phi of the way
  from the gas temperature down toward the coolant supply temperature.
- Coolant fraction from the energy balance: m_dot_c / m_dot_g =
  phi / (1 - phi) * CP_RATIO. A unit coolant-to-gas specific heat
  ratio (CP_RATIO = 1.0) is the documented simplification for
  conceptual design; the coolant heat capacity rate must offset the
  blade heat load implied by the effectiveness.
- Bleed limit: fractions up to BLEED_LIMIT = 0.20 are practical for a
  blade row; above that the cooling-air penalty on the cycle becomes
  prohibitive and the design must trade metal temperature, gas
  temperature or cooling scheme.
- Film cooling: film at the leading edge lifts the effectiveness by
  FILM_IMPROVEMENT = 0.15 over the internal-convection baseline,
  capped at PHI_CAP = 0.95. The achievable metal temperature is
  T_m = T_gas - phi_eff * (T_gas - T_coolant).
- Margin: margin_k = T_metal_allow - T_m. A positive margin means the
  cooling scheme holds the metal below the allowable temperature.
- Units are SI throughout: K, dimensionless ratios and fractions.

## Workflow

1. Fix the operating point: hot gas total temperature t_gas_k, the
   allowable blade metal temperature t_metal_allow_k and the coolant
   supply temperature t_coolant_k.
2. Compute the required cooling effectiveness with effectiveness;
   the function rejects non-physical inputs with ValueError.
3. Convert the effectiveness into the required coolant-to-gas mass
   flow fraction with coolant_fraction.
4. Check the fraction against the practical bleed limit with
   bleed_verdict; a fraction above 0.20 flags a design that needs
   revisiting.
5. Add the film cooling option: metal_temp_with_film with
   film_cooling=True returns the achievable metal temperature with the
   leading-edge film effectiveness gain.
6. Pull the whole estimate together with analyze, which reports
   effectiveness, coolant_fraction, verdict, metal_temp_k and margin_k
   in one dict.
7. Confirm the deterministic checks with the contract test
   scripts/test_turbine_blade_cooling.py.

## Worked example

Case 1: first blade row, t_gas = 1500 K, allowable metal 1200 K,
coolant 800 K.

- Effectiveness: phi = (1500 - 1200) / (1500 - 800) = 0.4286.
- Coolant fraction: 0.4286 / 0.5714 = 0.75, far above the 0.20 bleed
  limit, verdict "exceeds bleed limit".
- With film: phi_eff = 0.4286 + 0.15 = 0.5786, so
  T_m = 1500 - 0.5786 * 700 = 1095.0 K, margin +105 K. Film cooling
  brings the row inside the allowable metal temperature.

Case 2: high pressure turbine blade with film, t_gas = 1600 K,
allowable 1250 K, coolant 900 K.

- phi = 350 / 700 = 0.5, fraction 1.0, exceeds bleed limit.
- phi_eff = 0.65, T_m = 1600 - 0.65 * 700 = 1145 K, margin +105 K.

Case 3: t_gas = 1600 K, allowable 1350 K, coolant 900 K: phi = 250 /
700 = 0.3571, fraction 0.5556, still exceeds the bleed limit.

Sensitivity: at t_gas = 1500 K and coolant 800 K the required fraction
falls below 0.20 only when the allowable metal temperature exceeds
1383.33 K, about 117 K below the gas temperature.

## Verification

- Confirm effectiveness(1500, 1200, 800) returns 0.4286 and
  coolant_fraction of it returns 0.75.
- Confirm analyze(1500, 1200, 800, film_cooling=True) reports
  metal_temp_k 1095.0 K and margin_k 105.0 K.
- Confirm analyze(1600, 1250, 900, film_cooling=True) reports
  metal_temp_k 1145.0 K.
- Confirm rising allowable metal temperature lowers the required
  fraction monotonically and crosses below 0.20 at 1383.33 K.
- Confirm ValueError rejection: t_gas <= 0, t_gas <= t_coolant,
  t_metal_allow >= t_gas, t_metal_allow <= t_coolant, phi outside
  (0, 1), and negative coolant fractions.
- Run the contract test offline: python3
  scripts/test_turbine_blade_cooling.py (35 tests, deterministic).

## Related leaves

- propulsion/axial-compressor/turbine-stage: the velocity-triangle
  aerodynamic design of the same blade row, the sibling this leaf
  feeds with its allowable metal temperature context.
- propulsion/axial-compressor/multi-stage-compressor: the compression
  system that supplies the cooling bleed flow.
- propulsion/axial-compressor/compressor-map: bleed extraction points
  and their effect on the operating line.
- propulsion/gas-turbine-cycle leaves: the thermodynamic cycle cost of
  the cooling-air bleed.

## Pitfalls

- Accepting a coolant fraction above the bleed limit as a closed
  design: in all three worked-example cases the required fraction (0.75,
  1.0, 0.5556) far exceeds the 0.20 practical bleed limit, and only the
  film-cooling effectiveness gain brings the metal temperature inside -
  the bleed_verdict flags the trade, it does not validate it.
- Neglecting film cooling when the internal-convection fraction is
  prohibitive: adding FILM_IMPROVEMENT = 0.15 at the leading edge lifts
  the effectiveness (0.4286 to 0.5786 in case 1) and turns a 300 K
  over-temperature into a +105 K margin; reporting the baseline-only
  number understates what the row can achieve.
- Setting the allowable metal at or above the gas temperature: the
  effectiveness definition requires t_metal_allow < t_gas and above
  t_coolant; t_metal_allow >= t_gas or t_metal_allow <= t_coolant
  raises ValueError because the metal could not be held.
- Forgetting the film cap: film effectiveness is capped at PHI_CAP =
  0.95, so stacking film on top of an already high effectiveness does
  not keep improving the metal temperature without bound.
- Confusing the margin direction: margin_k = t_metal_allow - T_m is
  positive when the scheme holds the metal below the allowable; a
  negative margin means the metal is too hot, not a safety surplus.
- Reading the coolant fraction without the cycle and model context: the
  0.20 bleed limit exists because the cooling-air penalty becomes
  prohibitive above it (pair with the gas-turbine-cycle leaves), and
  CP_RATIO = 1.0 is a documented conceptual simplification - real
  cooling design needs 3D conjugate heat transfer analysis beyond this
  model.

## Behavior contract (gate 3)

Run the deterministic contract test (stdlib unittest, offline):

    python3 scripts/test_turbine_blade_cooling.py

The test covers the three worked-example operating points (effectiveness
within 1e-4, fractions within 1e-3, film metal temperatures within 1.0
K), the bleed-limit verdicts, the film effectiveness cap at 0.95, the
analyze dict outputs and margins, the sensitivity boundary crossing at
1383.33 K with the monotonic trend, and ValueError rejection of every
non-physical input.

## Compliance

- Standards referenced, not reproduced: FAR-33 is US government work
  (public domain) and covers engine type certification; the hot-section
  cooling relations above are simplified conceptual-design correlations,
  summary-only per standards-map.yaml. Real cooling design needs 3D
  conjugate heat transfer analysis beyond this model.
- compliance: STANDARDS-REF, gated: false.

Attribution

ashfordeOUashfordeOU
View sourceMore from ashfordeOU →
SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments (0)

No comments yet. Be the first to comment!

SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Related Skills

Caveman

Ultra-compressed communication mode that cuts output tokens while keeping technical accuracy. Levels: lite, full, ultra and the wenyan variants. Use for /caveman, "caveman mode", "talk like caveman", "be brief" or "less tokens".

1074701 votes

Hyperplan

Adversarial multi-agent planning skill. Self-orchestrates 5 hostile category members (unspecified-low, unspecified-high, deep, ultrabrain, artistry) via team-mode for ruthless cross-critique debate, distills only the defensible insights, then MANDATORILY hands the distilled insight bundle to the `plan` agent for executable plan formalization. Use when planning needs maximum rigor and surfacing of weak assumptions, blind spots, and over-engineering. Triggers: 'hyperplan', 'hpp', '/hyperplan', ...

694821 votes

Mcp Code Execution

Routes multi-tool workflows through MCP servers for large datasets and pipelines. Use when Bash tool overhead is limiting throughput on data-heavy tasks.

3351 votes

catchup

Recovers the conversation and failed tool calls of a previous Codex, Claude Code, Antigravity, Cline, Copilot CLI, Cursor, DeepSeek Harness, Kimi, OpenCode, Pi Agent, or ZCode session. Use when the user says "catch up", "what did the last session do", "get me up to speed", "I switched agents", asks to recover/summarize a previous session before continuing, or asks to diagnose or report a catchup failure. Do NOT use for the current conversation, git history, or any non-agent log.

691 votes

math-skill

A comprehensive mathematical reasoning skill for AI assistants — handles arithmetic to research-level problems with rigorous step-by-step reasoning, systematic verification, and transparent uncertainty handling

381 votes
View all in ai-agents →