Determine whether a sealed hybrid may be reopened under ECSS-Q-ST-60-05C clause 10.5.5, and what the reseal then owes. Use when a delid is proposed on a closed unit, for repair or for analysis: test whether that seal type can be reinstated at all, spend the reopen-cycle allowance and the sealing land each reseal consumes, read the reason to see whether the unit can return to deliverable stock, build the retest set the reseal carries, and return reopen-permitted, reopen-permitted-non-deliverab...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill q6005-package-delidding-rules --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Q6005 Package Delidding Rules?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-q6005-package-delidding-rules)More formats (shields.io, HTML) on the badges page.
---
name: q6005-package-delidding-rules
description: "Determine whether a sealed hybrid may be reopened under ECSS-Q-ST-60-05C clause 10.5.5, and what the reseal then owes. Use when a delid is proposed on a closed unit, for repair or for analysis: test whether that seal type can be reinstated at all, spend the reopen-cycle allowance and the sealing land each reseal consumes, read the reason to see whether the unit can return to deliverable stock, build the retest set the reseal carries, and return reopen-permitted, reopen-permitted-non-deliverable or reopen-not-permitted. Trigger: ecss, q-st-60-05c, hybrid-package-delidding, hybrid-lid-reseal-obligations, hybrid-delid-cycle-limit, hybrid-seal-land-consumption, hybrid-reseal-retest-set."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, q-st-60-05-hybrid-procurement, q6005-package-delidding-rules, hybrid-package-delidding, hybrid-lid-reseal-obligations, hybrid-delid-cycle-limit, hybrid-seal-land-consumption, hybrid-reseal-retest-set]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Hybrids — Delidding and Reseal (space-systems/ecss/q6005-package-delidding-rules)
Use when the task is clause 10.5.5 of ECSS-Q-ST-60-05C: opening a hybrid that
has already been sealed, and deciding in advance whether the package supports
it, whether the unit comes back afterwards, and what testing the reseal owes
before anyone calls the unit closed again.
## Domain quick reference
- A seal is not a lid. It is a joint made once out of the package material,
and reopening it destroys some of the material the next joint has to be
made from. That is why reopening has a count and not just a procedure.
- Seal types differ in kind, not only in degree. A weld or a solder seal can
be cut and remade; a fired glass seal cannot be reinstated to the condition
it was qualified in, and a unit sealed that way is not reopened with a view
to sending it on.
- The package carries two budgets that run down together but bind
separately. The cycle allowance counts reopenings; the sealing land counts
millimetres, and each reseal consumes a fixed width of it. A package can
have a cycle left and not enough land to use it.
- Why the unit is being opened decides where it goes, and the reseal quality
does not change that. An approved repair can put the unit back into
deliverable stock once it is closed and retested. Opening for failure
analysis, construction analysis or destructive physical analysis consumes
the unit — it was opened to be looked at, not to be recovered.
- Capability is part of permission. A unit that is to return to stock must be
reclosed by a qualified reseal process; without one, reopening it is a
decision to scrap it, and that decision should be taken deliberately rather
than discovered at the sealing station.
- The retest set is not fixed. It grows with what was done inside the
package — internal work adds pre-seal visual, interconnect verification and
a particle check — and with the route the unit takes, because returning to
stock adds re-screening that an analysis unit never needs.
- Leak testing is the point of the reseal, not a formality attached to it. A
reseal that has not been fine and gross leak tested has not been shown to
be a seal at all, whatever it looks like.
## Workflow
1. Validate the package: seal type, the sealing land it started with, and how
many times it has already been opened. An over-opened unit validates and
is graded, rather than being refused as bad input.
2. Validate the reason against the recognised set, because the reason decides
both the return route and what the reseal will owe.
3. Test resealability first. A seal type that cannot be reinstated makes
every downstream budget irrelevant, and saying so plainly is more useful
than reporting a cycle count for a package that has none.
4. Spend the cycle allowance, flooring the remainder at zero so an exhausted
package reads as exhausted rather than as a negative count.
5. Spend the sealing land: subtract one more reseal's consumption from the
starting land and compare the result with the minimum under a tolerance,
because a nominal package consumed down to exactly its minimum is an
ordinary outcome and must not flip on rounding.
6. Apply the return rule: a unit that is to go back needs a qualified reseal
capability, and a unit opened for analysis is recorded as leaving
deliverable stock whatever else is true.
7. Build the retest set from the seal type, the reason and whether internal
work was done, de-duplicated and in the order it will be performed, and
return it only where the reopening was actually permitted.
## Pitfalls
- Counting reopenings and forgetting the land. The cycle allowance is a proxy
for material consumption, and a package that started near its minimum
sealing land runs out of material before it runs out of cycles.
- Comparing the projected sealing land with a strict inequality. Fixed-width
reseals subtracted from a nominal dimension land exactly on the minimum
routinely, and without a tolerance the same package is accepted on one
machine and scrapped on another.
- Treating a fired glass seal as a harder version of a weld. It is a
different case: there is no reinstatement, so the answer is not a smaller
allowance but no allowance.
- Letting a good reseal recover an analysis unit. The disposition follows the
reason the package was opened, not the quality of the closure; a unit
opened for construction analysis has been consumed by the act.
- Deciding to reopen before checking that the facility can reseal. Reopening
is irreversible, and finding out afterwards that no qualified seal process
is available converts a repair into a scrap.
- Reusing one retest set for every reseal. Internal work adds pre-seal
verifications that a lid-only delid does not need, and a unit returning to
stock adds re-screening that an analysis unit never will.
- Reporting the retest set for a reopening that was refused. It reads as
authorisation, and a refused delid owes no tests because it should not
happen.
## Behavior contract (gate 3)
The seal-type and reason validation, the reopen-cycle allowance, the
sealing-land budget, the return-to-stock rule, the retest set assembly and
the three-way disposition are exercised by the gate 3 contract test:
scripts/test_q6005_package_delidding_rules.py against
scripts/q6005_package_delidding_rules_logic.py (stdlib unittest, offline).
Run:
python3 scripts/test_q6005_package_delidding_rules.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.