Use when you must size the environmental control system of a transport aircraft: compute the cabin ventilation fresh air flow from the occupant count and per-occupant rate, roll up the cabin heat load from occupants, solar, equipment and skin with a design margin, derive the pack cooling airflow from the heat load and the supply air temperature rise, take the pack airflow as the governing maximum of fresh and cooling flow, and build the cabin pressurization schedule that holds the design cabi...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill environmental-control-sizing --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Environmental Control Sizing?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-environmental-control-sizing)More formats (shields.io, HTML) on the badges page.
---
name: environmental-control-sizing
description: "Use when you must size the environmental control system of a transport aircraft: compute the cabin ventilation fresh air flow from the occupant count and per-occupant rate, roll up the cabin heat load from occupants, solar, equipment and skin with a design margin, derive the pack cooling airflow from the heat load and the supply air temperature rise, take the pack airflow as the governing maximum of fresh and cooling flow, and build the cabin pressurization schedule that holds the design cabin pressure altitude until the design differential pressure binds, then clamps at constant differential as the cabin altitude rises. Produces fresh air flow, cabin heat load, pack airflow, cabin differential at cruise and cabin altitude under both regimes. Trigger: environmental control system sizing, ECS, cabin ventilation, fresh air flow, pack cooling airflow, cabin heat load, pressurization schedule, cabin pressure altitude, differential pressure limit."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: far-25
reference-only: true
gated: false
domain: vehicle-design
pack: sizing
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: vehicle-design
subdomain: sizing
tags: [environmental-control-sizing, ecs-sizing, cabin-air-conditioning, cabin-heat-load, ventilation-flow, pack-cooling-flow, pressurization-schedule, cabin-altitude-limit]
version: 0.1.0
author: Aero Agent Skills
---
# Environmental Control System Sizing (vehicle-design/sizing/environmental-control-sizing)
Use when the task is sizing the environmental control system (ECS) of a
transport aircraft: the cabin ventilation fresh air flow from the
occupant count, the cabin heat load rollup (occupants, solar,
equipment, skin) with a design margin, the pack cooling airflow from
the heat load and the pack supply temperature rise, the pack airflow
verdict as the governing maximum of the fresh and cooling flows, and
the cabin pressurization schedule that holds the design cabin pressure
altitude until the design differential pressure binds and then flies
constant differential with the cabin altitude allowed to rise. This
leaf implements the sizing model in pure Python, stdlib only, with FAR
25 as the reference regulatory context. It pairs with
vehicle-design/sizing/ice-protection-sizing (the sibling aircraft-
subsystem sizing leaf; boundary: surface anti-icing bleed heating vs
cabin conditioning) and with cross-cutting/units-atmos/isa-atmosphere,
whose public two-layer atmosphere relation this leaf embeds internally
as private helpers only.
## Domain quick reference
- Fresh air flow: m_fresh = N * rate_per_occupant (default 0.25 kg/min
per occupant, the 0.55 lb/min practice), converted to kg/s by /60.
- Cabin heat load: Q_occ = N * q_occ; Q_total = Q_occ + Q_solar +
Q_equipment + Q_skin; Q_design = margin * Q_total (default margin
1.1).
- Pack cooling flow: m_cool = Q_design / (cp * dT_supply), with default
cp 1.005 kJ/(kg K) and default supply temperature rise 20 K. Pack
flow is the governing maximum: m_pack = max(m_fresh, m_cool), and
cooling_dominates records which side rules.
- Pressurization: p_amb = p_ISA(h_cruise); p_cab = p_ISA(h_cabin
design). Differential dP = p_cab - p_amb. While dP <= dP_max the
schedule holds the cabin altitude at the design value; when the
required differential would exceed dP_max the clamp binds, p_cab =
p_amb + dP_max * PSI, and the cabin altitude rises per the inverse
ISA (defaults: 8000 ft design cabin altitude, 8.9 psi design
differential).
- Internal two-layer ISA (private helpers, not a deliverable): p = P0
(1 - L h / T0)^(G/(L R)) in the troposphere to 11 km, then an
isothermal stratosphere at 216.65 K with scale height R T_strat / G.
The public atmosphere leaf is cross-cutting/units-atmos/isa-atmosphere.
- Units: SI (Pa, kg/s, K, kW, m) with ft and psi accepted at the
pressurization and altitude interfaces; PSI = 6894.757 Pa, FT =
0.3048 m.
- FAR 25 frames the cabin conditioning and pressurization context; the
relations above are standard engineering methodology, summary-only.
## Workflow
1. Fix the occupant count and the per-occupant ventilation rate, and
get the fresh air flow with fresh_air_flow (returns flow_kgmin and
flow_kgs).
2. Roll up the heat sources with cabin_heat_load: occupant heat at
q_occupant_kw each, plus solar, equipment and skin heat, closed by
the design margin to give design_heat_kw.
3. Size the pack with pack_airflow on the design heat, cp and supply
temperature rise; pass the fresh flow so the verdict reflects the
governing maximum of ventilation and cooling (cooling_dominates).
4. Build the pressurization schedule with pressurization_schedule at
the cruise altitude, design cabin altitude and design differential:
read differential_limited to know whether the clamp binds, and
cabin_altitude_ft for the resulting cabin altitude.
5. For a one-call rollup run ecs_summary with every input to get the
combined dict of all outputs.
6. Confirm the deterministic checks with the contract test
scripts/test_environmental_control_sizing.py.
## Worked example
Reference transport: 189 occupants at 0.25 kg/min each, 0.12
kW/occupant, solar 15 kW, equipment 12 kW, skin 8 kW, margin 1.1, cp
1.005 kJ/(kg K), supply temperature rise 20 K, design cabin altitude
8000 ft, design differential 8.9 psi, cruise 39000 ft then 50000 ft.
- fresh_air_flow(189): flow_kgmin = 47.25 kg/min, flow_kgs = 0.7875
kg/s.
- cabin_heat_load(189, 0.12, 15, 12, 8): occupant_heat_kw = 22.68 kW,
total_heat_kw = 57.68 kW, design_heat_kw = 63.448 kW.
- pack_airflow(63.448): cooling_flow_kgs = 3.156617 kg/s (63.448 /
(1.005 * 20)), pack_flow_kgs = 3.156617 kg/s, cooling_dominates True.
- pressurization_schedule(39000): p_amb = 19.677 kPa, p_cab = 75.262
kPa (the 8000 ft cabin), differential = 8.0619 psi, below the 8.9 psi
limit so the schedule HOLDS: cabin_altitude_ft = 8000.0,
differential_limited False.
- pressurization_schedule(50000): p_amb = 11.597 kPa; holding 8000 ft
would need 9.234 psi, above the limit, so the clamp binds:
differential_limited True, p_cab = 72.960 kPa (ambient + 8.9 psi),
cabin_altitude_ft = 8809.9 ft, above the 8000 ft design value in the
differential-limited regime.
## Pitfalls
- Sizing the pack on the fresh-air flow alone: the pack airflow is
the governing MAXIMUM of the fresh ventilation flow and the
cooling flow (3.1566 kg/s cooling dominates 0.7875 kg/s fresh in
the worked example); picking the smaller flow starves the cabin
heat load.
- Forgetting the design margin in the heat rollup: the design heat
is margin * total (default 1.1), so an undiscounted total heat
under-sizes the pack by the margin ratio.
- Reading the differential at cruise as the limit: at 39000 ft the
8.0619 psi differential holds the 8000 ft cabin below the 8.9 psi
clamp; only above the altitude where the clamp binds does the
schedule leave the design cabin altitude (8809.9 ft at 50000 ft).
- Feeding a margin at or below 1: the margin must exceed 1 (the
design heat carries reserve); a margin of 1.0 or less raises
ValueError.
- Confusing which flow cools and which ventilates: fresh air
(occupants at 0.25 kg/min each) is a ventilation requirement,
while the pack cooling flow derives from the heat load and the
supply temperature rise; the two answer different questions.
- Mixing pressure units at the interfaces: pressurization accepts ft
and psi with internal conversions (PSI = 6894.757 Pa), so feeding
Pa or m into those interfaces silently mis-sizes the schedule.
## Verification
- fresh_air_flow(189) returns 47.25 kg/min and 0.7875 kg/s; flow is
linear in the occupant count.
- cabin_heat_load rolls the four sources into total_heat_kw and
design_heat_kw = margin * total exactly; margin 1.5 scales the design
heat by 1.5/1.1.
- pack_airflow(63.448) returns cooling_flow_kgs 3.156617 kg/s to 1e-6;
with fresh_flow_kgs = 5.0 the pack flow equals the fresh flow and
cooling_dominates is False.
- At 39000 ft the schedule holds 8000 ft exactly (differential 8.0619
psi within 1e-4); at 50000 ft the clamp binds, cabin pressure equals
ambient plus 8.9 * PSI within 1e-3 Pa and the cabin altitude lands in
(8800, 8820) ft.
- The internal ISA is continuous at the tropopause and round-trips
_h_isa_from_p(_p_isa(h)) == h to 1e-6 m in both regions.
- ValueError rejects: occupants <= 0, rate <= 0, margin <= 1, any
negative heat input, design_heat_kw <= 0, cp <= 0, dT_supply_k <= 0,
fresh_flow_kgs < 0, cruise_alt_ft < 0, cabin_alt_design_ft < 0 and
dP_max_psi <= 0.
- Run the contract test offline: python3
scripts/test_environmental_control_sizing.py (33 tests,
deterministic).
## Related leaves
- vehicle-design/sizing/ice-protection-sizing: sibling aircraft-
subsystem sizing leaf; boundary is surface anti-icing bleed heating
versus cabin conditioning.
- vehicle-design/sizing/battery-sizing: the electric power subsystem
sizing leaf for the power offtake context around the ECS loads.
- cross-cutting/units-atmos/isa-atmosphere: the public atmosphere leaf
whose two-layer relation this leaf embeds internally.
## Behavior contract (gate 3)
Run the deterministic contract test (stdlib unittest, offline):
python3 scripts/test_environmental_control_sizing.py
The test covers the worked-example magnitudes (47.25 kg/min fresh
flow, 63.448 kW design heat, 3.156617 kg/s pack cooling flow), the
pressurization hold at 39000 ft with differential 8.0619 psi and the
clamp at 50000 ft with cabin altitude 8809.9 ft, the regime boundary
crossing monotonicity, linearity in occupants, the margin scaling
ratio, internal ISA tropopause continuity and pressure round-trip in
both regions, ecs_summary rollup, run-to-run determinism and ValueError
rejection of every non-physical input.
## Compliance
- Standards referenced, not reproduced: FAR 25 frames the cabin
conditioning and pressurization context; the sizing relations above
are standard engineering methodology, summary-only per standards-map.
- compliance: STANDARDS-REF, gated: false.