Verify the electrical design of an explosive initiation circuit against ECSS-E-ST-33-11C clause 4.8.2. Use when the task is screening every path that can put energy into a bridgewire: grading the worst-case stray current against the no-fire current, converting a radio-frequency field into pickup voltage and delivered power and comparing it with the no-fire power, sizing an electrostatic discharge as stored energy and grading it pin-to-pin and pin-to-case, checking that coupled nuclear-pulse e...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e3311-electrical-requirements --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E3311 Electrical Requirements?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e3311-electrical-requirements)More formats (shields.io, HTML) on the badges page.
---
name: e3311-electrical-requirements
description: "Verify the electrical design of an explosive initiation circuit against ECSS-E-ST-33-11C clause 4.8.2. Use when the task is screening every path that can put energy into a bridgewire: grading the worst-case stray current against the no-fire current, converting a radio-frequency field into pickup voltage and delivered power and comparing it with the no-fire power, sizing an electrostatic discharge as stored energy and grading it pin-to-pin and pin-to-case, checking that coupled nuclear-pulse energy leaves the required margin and that an immunity demonstration exists, and confirming the firing-line wiring carries every declared control. Trigger: ecss, e-st-33-11-explosive-subsystem-scope, electro-explosive-no-fire-margin, stray-current-no-fire-screen, eed-rf-immunity-margin, eed-esd-withstand-energy, nemp-initiation-immunity, firing-line-wiring-integrity."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-33-11-explosive-subsystem-scope, e3311-electrical-requirements, electro-explosive-no-fire-margin, stray-current-no-fire-screen, eed-rf-immunity-margin, eed-esd-withstand-energy, nemp-initiation-immunity, firing-line-wiring-integrity]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Explosive Subsystems — Electrical Requirements (space-systems/ecss/e3311-electrical-requirements)
Use when the task is the electrical screen of ECSS-E-ST-33-11C clause
4.8.2 -- showing that no path available to the flight environment, the
platform harness or the ground support equipment can put firing-level
energy into an electro-explosive device before the device is meant to
fire.
## Domain quick reference
- An electro-explosive device is a resistor that detonates, so every
electrical requirement on it reduces to one question asked along
several paths at once: how much energy can reach the bridgewire, and
how far below the level that initiates it does that energy sit.
- The screening quantities are the no-fire current, the no-fire power
and the electrostatic withstand energy. The first two are what the
device tolerates indefinitely without initiating; the third is what
it tolerates as a single discharge, and it is declared separately
pin-to-pin and pin-to-case because the two paths run through
different insulation.
- Stray current is graded as a fraction of the no-fire current rather
than in decibel, because the quantity the circuit analysis produces
is a current and the allowance is conventionally a percentage. A
margin in decibel is still reported so the result can be compared
with the radio-frequency and pulse paths.
- Radio-frequency pickup is a two-step computation, not a lookup. The
field and the effective length of the firing-line pair give an
open-circuit voltage; that voltage into a matched bridgewire load
gives the delivered power; only then is there something to compare
with the no-fire power.
- An electrostatic discharge is sized from the source, not the device:
the stored energy of the charged body sets what arrives, and the
device's declared withstand sets what is survivable. The ratio of
the two is the margin, and it is taken per path.
- A nuclear-pulse margin computed from a coupling estimate is not the
same as a demonstrated immunity. Both are recorded, and a missing
demonstration is a finding even when the arithmetic is comfortable.
- Wiring integrity is a checklist rather than a number, but it is a
closed one: an undeclared control is a gap in the evidence, not an
implicit pass.
## Workflow
1. Fix the two device quantities everything else is graded against --
the no-fire current and the no-fire power -- and reject a case that
supplies neither, because every margin below is a ratio to them.
2. Grade the worst-case stray current. Take the allowance as the
declared fraction of the no-fire current, report the shortfall in
both amperes and decibel, and treat a case sitting exactly on the
allowance as compliant rather than failing it on representation
error.
3. Work the radio-frequency path through in order: field times
effective length for the induced voltage, that voltage into the
matched bridgewire for the delivered power, then the power margin
against the policy requirement.
4. Size the electrostatic discharge from the source capacitance and
voltage, then grade the pin-to-pin and pin-to-case withstands
separately. Reject a case that declares only one path; the missing
one is the one that usually fails.
5. Grade the coupled nuclear-pulse power against the same power margin
and record whether an immunity demonstration backs it.
6. Walk the firing-line wiring controls and name each one that is
absent, then close with the overall verdict and the list of paths
that produced it.
## Pitfalls
- Grading stray current against the all-fire level instead of the
no-fire level. The all-fire current is what the circuit must deliver
on command; the no-fire current is what everything else must stay
under, and the gap between them is the whole safety case.
- Comparing a field strength directly with a no-fire power. They are
not the same kind of quantity, and skipping the pickup computation
hides the two parameters that actually drive the answer: how long
the firing-line pair is and what the bridgewire looks like as a
load.
- Taking one electrostatic withstand figure as covering both paths.
Pin-to-case runs through the device housing insulation and is
routinely the weaker of the two, so a single number quoted for the
device grades the path that was never the concern.
- Reading a comfortable nuclear-pulse margin as immunity. The margin
is only as good as the coupling estimate behind it, and an estimate
with no test behind it is an assumption with a decimal point.
- Treating an undeclared wiring control as satisfied. The control set
is closed, so a silent entry means nobody looked, and a firing line
that is not shorted until arm fails in exactly the configuration
nobody inspected.
- Comparing margins by bare arithmetic. Each one is a ratio or a
difference of logarithms, so a design sitting exactly on its
requirement can land a few units in the last place below it; the
comparison absorbs that while the requirement stays untouched.
## Behavior contract (gate 3)
The stray-current allowance, radio-frequency pickup chain,
electrostatic per-path grading, nuclear-pulse margin and demonstration
check, wiring-control walk and overall verdict are exercised by the
gate 3 contract test:
scripts/test_e3311_electrical_requirements.py against
scripts/e3311_electrical_requirements_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e3311_electrical_requirements.py