Evaluate a two-phase heat transport thermal performance test against ECSS-E-ST-31-02C clause 5.6.9. Use when the task is mapping a transport device over its power and temperature envelope: subtracting the parasitic leak to get the power that actually crossed the device, forming the evaporator-to-condenser drop and the transport conductance it cost, grading each point against the capability interpolated at its own operating temperature, confirming every required power and sink-temperature cell...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e3102-thermal-performance-test --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E3102 Thermal Performance Test?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e3102-thermal-performance-test)More formats (shields.io, HTML) on the badges page.
---
name: e3102-thermal-performance-test
description: "Evaluate a two-phase heat transport thermal performance test against ECSS-E-ST-31-02C clause 5.6.9. Use when the task is mapping a transport device over its power and temperature envelope: subtracting the parasitic leak to get the power that actually crossed the device, forming the evaporator-to-condenser drop and the transport conductance it cost, grading each point against the capability interpolated at its own operating temperature, confirming every required power and sink-temperature cell was run to steady state, judging the start-up demonstration on the time transport took to establish from a cold device, and grading the regulation demonstration on the worst deviation held around the setpoint. Trigger: ecss, e-st-31-02c, two-phase-transport-performance-test, heat-transport-power-mapping, transport-capability-utilisation, evaporator-condenser-temperature-drop, heat-transport-start-up-demonstration, transport-setpoint-regulation-band, transport-steady-state-dwell."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-31-02-two-phase-transport-scope, e3102-thermal-performance-test, heat-transport-power-mapping, transport-capability-utilisation, evaporator-condenser-temperature-drop, heat-transport-start-up-demonstration, transport-setpoint-regulation-band, transport-steady-state-dwell]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Two-Phase Heat Transport — Thermal Performance Test (space-systems/ecss/e3102-thermal-performance-test)
Use when the task is the thermal performance test of ECSS-E-ST-31-02C
clause 5.6.9 -- mapping a heat pipe, loop or capillary-pumped transport
assembly across the power and temperature envelope it is qualified for,
and adding the two demonstrations a steady map cannot make on its own:
start-up from a cold device, and regulation around a control setpoint.
## Domain quick reference
- The number being mapped is the transported power, not the heater
draw. Whatever leaked to the surroundings between the heater and the
evaporator never crossed the transport path, so the parasitic loss is
subtracted before any grading happens. A map built on applied power
credits the device with heat it never carried.
- Each mapped point is a pair: the power carried, and the
evaporator-to-condenser temperature drop it cost. Their quotient is
the transport conductance, which is the figure that actually tracks
degradation from one test to the next. A point where the two ends read
the same temperature yields no conductance at all; the instrumentation
simply cannot resolve it, and that is a finding, not a zero.
- Transport capability is a function of operating temperature, not a
single number. The capability a point is graded against is
interpolated from the declared curve at that point's own condenser
temperature, and a point outside the declared curve span is refused
rather than extrapolated -- continuing the last slope is how a
beyond-capability point comes back reported as compliant.
- The map is a matrix, so coverage is part of the result. Every required
power and sink-temperature cell has to have been run, and run to
steady state: a point taken while the assembly was still drifting
records a transient, and a drift rate is the cheapest available proof
that the dwell was long enough.
- Start-up is a separate demonstration because a two-phase device that
runs well once primed can fail to prime at all. It is graded on two
facts: whether transport established from the declared cold initial
condition, and how long that took against the declared limit.
- Regulation is graded on the worst deviation over the sample record,
not the mean. An assembly that averages onto its setpoint while
excursions leave the band has not held the band.
## Workflow
1. Take the capability curve and check it is usable: at least two
points, strictly increasing temperature, positive capability. A curve
that is not monotonic is rejected rather than sorted, because the
reordering would silently invent a capability nobody declared.
2. For each mapped point, subtract the parasitic loss from the applied
power, form the temperature drop, and refuse a point whose condenser
reads above its evaporator -- that geometry is reversed and the point
is not interpretable.
3. Interpolate the capability at the point's condenser temperature,
divide the transported power by it, and categorize the point as
within, exactly on, or beyond the capability.
4. Assess the dwell: compare the recorded drift rate against the steady
limit and mark an unsettled point as not accepted whatever its
utilisation says.
5. Check the coverage matrix cell by cell and list the required power
and sink-temperature combinations no point matched.
6. Grade the start-up demonstration on establishment and elapsed time,
and the regulation demonstration on the worst deviation from the
setpoint.
7. Close with one verdict: the performance is demonstrated only when
every point is accepted, the matrix is complete, and both
demonstrations passed.
## Pitfalls
- Reporting the heater setting as the transported power. The parasitic
leak is often a few per cent near the top of the envelope and a large
fraction at the bottom, so the error is worst exactly where the
low-power start of the map is being qualified.
- Grading every point against one capability figure. The capability
moves with operating temperature, and a cold-end point graded against
a warm-end capability can be well beyond the real limit while the
arithmetic reports margin.
- Extrapolating the capability curve past its declared span. The curve
is evidence over the range it was measured on; beyond that it is a
guess with a slope attached, and the guess always flatters the device.
- Accepting a point that was still drifting. A transient reads as a
smaller temperature drop than the settled value, so an unsettled point
reports a better conductance than the device actually has.
- Treating the mapping as complete because every point that was run
passed. Coverage and pass rate are different questions, and a matrix
with untried cells has simply not been mapped there.
- Comparing a utilisation, a drift rate or a start-up time against its
limit by bare arithmetic. Each is the result of a division, so a case
that is exactly on the limit can land a few units in the last place on
the wrong side of it; the comparisons absorb that representation error
while the limits themselves stay untouched.
## Behavior contract (gate 3)
The parasitic subtraction, temperature-drop and conductance formation,
capability interpolation with its extrapolation refusal, utilisation
grading, steady-state assessment, matrix coverage, start-up and
regulation demonstrations and the overall verdict are exercised by the
gate 3 contract test:
scripts/test_e3102_thermal_performance_test.py against
scripts/e3102_thermal_performance_test_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e3102_thermal_performance_test.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.