Evaluate a thermal control item operating below two hundred kelvin against the cryogenic design constraints of ECSS-E-ST-31 clause 4.2.3 and its cryogenic annex: confirm the temperature sensor still resolves the cold end with usable sensitivity, decide whether a mechanical thermostat is qualified that low or must be replaced by an electronic controller, hold the interface gradient inside its allowable, and widen every material property by the scatter it acquires below the boundary before a he...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e31-cryogenic-range-design-requirements --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E31 Cryogenic Range Design Requirements?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e31-cryogenic-range-design-requirements)More formats (shields.io, HTML) on the badges page.
---
name: e31-cryogenic-range-design-requirements
description: "Evaluate a thermal control item operating below two hundred kelvin against the cryogenic design constraints of ECSS-E-ST-31 clause 4.2.3 and its cryogenic annex: confirm the temperature sensor still resolves the cold end with usable sensitivity, decide whether a mechanical thermostat is qualified that low or must be replaced by an electronic controller, hold the interface gradient inside its allowable, and widen every material property by the scatter it acquires below the boundary before a heat leak is quoted. Use when a unit has been grouped into the cryogenic range and its sensing, control and conduction assumptions need checking. Trigger: ecss, e-st-31, cryogenic-tcs-design-constraints, cryogenic-sensor-sensitivity, cryogenic-thermostat-deadband, cryogenic-interface-gradient, cryogenic-property-scatter, cryogenic-heat-leak-band."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-31-thermal-control-scope, e31-cryogenic-range-design-requirements, cryogenic-tcs-design-constraints, cryogenic-sensor-sensitivity, cryogenic-thermostat-deadband, cryogenic-interface-gradient, cryogenic-property-scatter]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Thermal Control — Cryogenic Range Design Requirements (space-systems/ecss/e31-cryogenic-range-design-requirements)
Use when the task is the clause 4.2.3 step of ECSS-E-ST-31 and its cryogenic
annex: an item has already been placed in the cryogenic range, and the
sensing, control, gradient and material assumptions carried over from
room-temperature practice now have to be re-examined before they are relied
on.
## Domain quick reference
- A sensor has a usable span, not just a range printed on a datasheet. Its
sensitivity — the signal it produces per kelvin — collapses at one end of
that span, and a sensor reading a tenth of a millivolt per kelvin cannot
hold a control loop no matter how well it is calibrated. Both the span
coverage and the sensitivity at the cold end have to be checked.
- Mechanical thermostats are qualified down to a temperature and no further.
Below it the bimetal stiffens, the snap action slows and the deadband
widens, so a controller qualified at room temperature can be sitting at
several times its catalogue deadband in the cold case. Where the widened
deadband exceeds the allowable control band, an electronic controller is
the answer, not a tighter set point.
- Gradients matter more, not less, when everything is cold. The same heat
leak across a joint produces a larger fractional temperature error at
twenty kelvin than at three hundred, and detector and structure alignment
requirements are usually written against the gradient rather than the
absolute level.
- Material properties scatter below the range boundary. Thermal conductivity,
specific heat and expansion coefficient are measured on fewer samples at
cryogenic temperatures and vary more between lots, so a single catalogue
value is a mid-estimate rather than a design value.
- The consequence is that a cryogenic heat leak is a band, not a number. The
design has to work at the high-conductivity end of the scatter and the
cooler sizing has to survive it, so the two ends of the band are both
carried rather than averaged.
- Scatter and prediction uncertainty are different quantities and both apply.
Collapsing them into one allowance is how a cryogenic chain ends up with a
margin that exists only on paper.
## Workflow
1. Validate the item: an operating range wholly or partly below the cryogenic
boundary, positive temperatures, and a range that does not run backwards.
An item entirely above the boundary is not this skill's subject and is
refused rather than quietly graded.
2. Check the sensor: its usable span must cover the operating range with the
declared margin at both ends, and its sensitivity at the cold end must
meet the floor the control electronics need.
3. Check the controller: take the catalogue deadband, apply the cold growth
factor if the set point sits below the mechanical qualification floor, and
compare the widened deadband with the allowable control band. Record the
need for an electronic controller as a finding rather than a failure.
4. Check the interface gradient against its allowable, absorbing
representation error at the boundary with a named tolerance.
5. Widen each material property: the nominal value is multiplied out to a low
and a high bound using the scatter fraction, itself multiplied by the
cryogenic scatter factor when the item sits below the boundary.
6. Propagate the conductivity band into a conduction heat leak band using the
conductive path geometry and the temperature difference across it.
7. Size the cooler or cold-strap against the high end of the heat-leak band,
never the mid value, and report the required capacity alongside the band.
8. Report a per-constraint verdict and the findings, so a unit that fails one
constraint is not reported as failing all of them.
## Pitfalls
- Reading only the sensor's stated range. Range coverage without sensitivity
gives a sensor that is technically in range and practically useless for
control at the cold end.
- Keeping a mechanical thermostat below its qualification floor because it
"still clicks". The deadband is what moved, and the control band is what it
broke.
- Sizing a cooler on the nominal conductivity. Half the population sits above
it, and the cooler either runs out of capacity or spends its entire margin.
- Averaging the property band into a single design value. The point of the
band is that both ends have to be survivable; an average is survivable in
neither direction on its own.
- Folding scatter into the prediction uncertainty. They are independent
contributions and combining them by hand usually means one of them silently
disappeared.
- Checking the absolute temperature and not the gradient. Alignment and
detector performance requirements are written against the gradient, and it
is the constraint that goes red first.
## Behavior contract (gate 3)
The cryogenic-range admission check, sensor span and sensitivity check,
thermostat deadband growth and control-band comparison, gradient check,
property scatter banding, conduction heat-leak band and cooler sizing are
exercised by the gate 3 contract test:
scripts/test_e31_cryogenic_range_design_requirements.py against
scripts/e31_cryogenic_range_design_requirements_logic.py (stdlib unittest,
offline). Run: python3 scripts/test_e31_cryogenic_range_design_requirements.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.