Verify the device voltage drop at which an output-impedance dataset was measured and reported, under ECSS-E-ST-20-20C clause 5.2.17.2.1. Use when a characterisation has to name its bias point instead of leaving the operating condition implicit: refuse a drop larger than the bus feeding it, take the declared drop against the reference bias point, compare it with the drop the reported load current and series resistance imply, hold it inside the device operating window, take the implied dissipat...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2020-output-impedance-bias-condition --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2020 Output Impedance Bias Condition?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2020-output-impedance-bias-condition)More formats (shields.io, HTML) on the badges page.
---
name: e2020-output-impedance-bias-condition
description: "Verify the device voltage drop at which an output-impedance dataset was measured and reported, under ECSS-E-ST-20-20C clause 5.2.17.2.1. Use when a characterisation has to name its bias point instead of leaving the operating condition implicit: refuse a drop larger than the bus feeding it, take the declared drop against the reference bias point, compare it with the drop the reported load current and series resistance imply, hold it inside the device operating window, take the implied dissipation against the device limit, and refuse a set whose classes each pass yet straddle the tolerance as a group. Trigger: ecss, e-st-20-20c-clause-5-2-17-2, lcl-output-impedance-bias-condition, device-voltage-drop-bias-point, output-impedance-measurement-condition, series-element-voltage-drop, bias-point-commonality, protection-device-dissipation-limit."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-20-power-protection-device-scope, e2020-output-impedance-bias-condition, lcl-output-impedance-bias-condition, device-voltage-drop-bias-point, output-impedance-measurement-condition, series-element-voltage-drop, bias-point-commonality, protection-device-dissipation-limit]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Power Protection Devices -- Output Impedance Bias Condition (space-systems/ecss/e2020-output-impedance-bias-condition)
Use when the task is the clause 5.2.17.2.1 measurement condition of
ECSS-E-ST-20-20C: the output impedance data supplied for a protection
device has to name the voltage the device was dropping across itself
when the data was taken, and that bias point has to be shown to be the
one the project fixed.
## Domain quick reference
- An impedance figure without its operating point is not a figure. The
series element of a protection device is a controlled semiconductor,
not a resistor, so how hard it is being driven changes the
small-signal impedance the load behind it sees. The drop across the
device is the handle the clause uses to pin that down.
- The drop is what makes two suppliers comparable. Two curves taken at
two different bias points are two different measurements of two
different operating conditions, and laying them over each other
produces a family spread that is an artefact of the test setup.
- A declared drop and a measured drop are not the same claim. The
declared figure can be carried forward from a template while the
reported load current and series resistance imply something else
entirely, so the two are reconciled against each other rather than
taken on trust.
- The operating window has two ends and both matter. Too small a drop
and the series element is barely conducting, so the measurement sits
in a region the device never actually works in; too large and the
element is closer to limitation than to its normal operating point,
and the curve carries that in it.
- Per-record agreement does not give set agreement. Two classes can each
sit inside the reference tolerance while landing on opposite sides of
it, which puts twice the tolerance between them; the spread across
the reported set is therefore its own separate check.
- Dissipation follows from the bias point for free. The drop times the
current is what the series element has to shed, and a bias point that
is defensible on impedance grounds can still be one the device cannot
hold thermally.
- The reference and consistency tolerances, the operating window, the
dissipation limit and the bus-share advisory ceiling are declared
project policy rather than physical constants; the defaults in the
logic module are a starting point a project substitutes its own values
into.
## Workflow
1. Validate the policy: tolerances inside zero to one, an operating
window that ascends, and a positive dissipation limit. A window that
does not ascend is a data error, not a tight specification.
2. Validate each reported record: a positive declared drop, load
current, series resistance and bus voltage, a unique class name, and
a drop no larger than the bus feeding the device.
3. Validate the reference bias point itself against the operating
window. A reference nobody can operate at fails the whole set and is
refused up front rather than reported once per class.
4. Take the declared drop against the reference bias point as a relative
deviation, and report it whether or not it passes so a reviewer sees
which record sits nearest its bound.
5. Reconstruct the drop from the reported load current and series
resistance and compare it with the declared one. Report the two
deviations separately: a record can be on the reference and still be
internally inconsistent, and that is a different defect.
6. Hold the declared drop inside the operating window, and take the
implied dissipation at that drop and current against the device
limit.
7. Take the spread of declared drops across the whole reported set
against the same tolerance, and report a set that fails it even when
every individual record passed.
8. Report the share of the bus voltage the device is holding as an
advisory, so a bias point that is compliant but wasteful is visible.
## Pitfalls
- Reporting impedance without the bias point. The curve then cannot be
compared with another supplier's, reproduced by the customer, or used
in a stability case, and the omission is usually noticed only once two
datasets disagree for no visible reason.
- Taking the declared drop on trust. The current and the series
resistance in the same record imply a drop of their own, and a
template value that survived a copy is caught by exactly that
comparison and by nothing else.
- Treating per-record agreement as set agreement. Records on opposite
edges of the tolerance are each compliant and are twice the tolerance
apart, which is why the spread across the set is checked separately.
- Choosing the bias point on impedance grounds alone. The same drop sets
the dissipation the series element has to shed at the reported
current, and a thermally impossible bias point is not a bias point.
- Comparing a reconstructed drop or a dissipation by bare arithmetic.
Both come out of multiplication, so a case meant to sit exactly on a
limit can land a few units in the last place above it; the comparison
absorbs that representation error while the limit stays as declared.
## Behavior contract (gate 3)
The policy validation, record validation, implied-drop and dissipation
arithmetic, relative deviation, reference and consistency comparisons,
operating-window and dissipation bounds, bus-share advisory, declared
drop spread and the set verdict are exercised by the gate 3 contract
test: scripts/test_e2020_output_impedance_bias_condition.py against
scripts/e2020_output_impedance_bias_condition_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2020_output_impedance_bias_condition.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.