Use when a thermo optical data sheet, integrating sphere record or emissometer log has to be assessed. Compute the solar absorptance and hemispherical emittance that clause 6.4.3.6.2 of ECSS-E-ST-20-08C asks to be measured on the designated subgroup of cell assemblies: reconcile the samples actually measured against the subgroup the plan designated, weight the measured reflectance bands into an absorptance and an emittance, derive the absorptance to emittance ratio, hold repeat scans inside t...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-sca-thermo-optical-measurement-process --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Sca Thermo Optical Measurement Process?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-sca-thermo-optical-measurement-process)More formats (shields.io, HTML) on the badges page.
---
name: e2008-sca-thermo-optical-measurement-process
description: "Use when a thermo optical data sheet, integrating sphere record or emissometer log has to be assessed. Compute the solar absorptance and hemispherical emittance that clause 6.4.3.6.2 of ECSS-E-ST-20-08C asks to be measured on the designated subgroup of cell assemblies: reconcile the samples actually measured against the subgroup the plan designated, weight the measured reflectance bands into an absorptance and an emittance, derive the absorptance to emittance ratio, hold repeat scans inside the instrument repeatability limit, and refuse a band the instrument spectral range never covered. Trigger: ecss, e-st-20-08c, sca-thermo-optical-measurement-process, solar-cell-assembly-solar-absorptance, sca-hemispherical-emittance-measurement, sca-thermo-optical-subgroup-coverage, sca-reflectance-band-instrument-range."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2008-sca-thermo-optical-measurement-process, e-st-20-08c, sca-thermo-optical-measurement-process, solar-cell-assembly-solar-absorptance, sca-hemispherical-emittance-measurement, sca-thermo-optical-subgroup-coverage, sca-reflectance-band-instrument-range]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Solar Cell Assemblies — Thermo Optical Measurement (space-systems/ecss/e2008-sca-thermo-optical-measurement-process)
Use when the task is clause 6.4.3.6.2 of ECSS-E-ST-20-08C: solar absorptance
and hemispherical emittance measured on the subgroup of cell assemblies the
test plan designated for it. This leaf reduces the reflectance scans into the
two properties and their ratio, decides whether the instrument could see the
bands it reported, holds the repeat scans against a repeatability limit, and
names the designated sample that never reached the bench.
## Domain quick reference
- These two numbers set the equilibrium temperature of the array. The
absorptance decides how much sunlight becomes heat, the emittance decides
how much of that heat leaves, and the ratio between them is what a thermal
model actually consumes. A small error in either walks the predicted
temperature by tens of kelvin.
- Both properties are weighted means, not averages. Absorptance is one minus
the reflectance weighted by the solar spectrum; emittance is one minus the
reflectance weighted by the thermal emission spectrum. Averaging the same
bands without their weights produces a different number that looks equally
plausible on the data sheet.
- The two properties live in different parts of the spectrum and are measured
by different instruments. A band reported outside the spectral range of the
instrument that returned it is an extrapolation of that instrument's own
calibration, so the reflectance there is not a measurement.
- One scan is a number, not a measurement. Repeat scans of the same sample
are the only evidence available that the bench is repeatable, so the
declared number of them is a requirement and their spread is the figure
that decides whether the mean means anything.
- The subgroup is designated by the plan, not chosen at the bench. Measuring
the convenient samples instead of the designated ones closes the count and
leaves the subgroup open, which is why coverage is resolved both ways:
designated but unmeasured, and measured but never designated.
## Workflow
1. Reduce every scan of every sample: weight the solar bands into an
absorptance, weight the thermal bands into an emittance.
2. Check each band against the spectral range of the instrument that reported
it, absorbing floating-point representation error at the range edges with
a named tolerance rather than by widening the instrument range.
3. Average the repeat scans into the reported absorptance and emittance for
that sample, and derive the absorptance to emittance ratio from those
means.
4. Hold the scan count against the declared number of repeats and the spread
of the repeats against the declared repeatability limit; a sample with one
scan has no repeatability evidence at all.
5. Reconcile the identifiers measured against the identifiers designated,
both ways, and report each direction separately.
6. Reject a sample or a designated identifier that appears twice; two records
under one name make the subgroup ambiguous rather than redundant.
7. Roll the subgroup up into mean properties and a verdict that any coverage
shortfall overrides.
## Pitfalls
- Reporting a single scan as the sample value. The number is indistinguishable
from a repeatable one until a second scan exists, and the first sample to be
re-measured for an anomaly is usually the one that never had a pair.
- Averaging the reflectance bands unweighted. The solar spectrum is far from
flat across the band set, so the unweighted mean quietly reweights the
measurement toward wherever the bench happened to place its points.
- Accepting a thermal band from a solar-range instrument. The instrument
returns a value, it just is not a calibrated one, and nothing downstream
marks that value as different from the others.
- Reading the ratio without both properties. An assembly can hold its ratio
while both absorptance and emittance drift together, which is a different
physical state from the one the ratio alone suggests.
- Counting samples instead of resolving identifiers. A subgroup of six
measured six times is complete by count and can still be missing two
designated samples while carrying two nobody asked for.
## Behavior contract (gate 3)
The weighted reduction into absorptance and emittance, the ratio, the repeat
scan count and spread against the repeatability limit, the instrument
spectral range check and the two-way subgroup coverage are exercised by the
gate 3 contract test:
scripts/test_e2008_sca_thermo_optical_measurement_process.py against
scripts/e2008_sca_thermo_optical_measurement_process_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2008_sca_thermo_optical_measurement_process.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.