Use when an ESD-sensitive diode is handled, packed or stored. Assess whether the handling and storage regime applied to an electrostatic-discharge-sensitive protection diode keeps it under the voltage it survives, per ECSS-E-ST-20-08C clause 9.10.2: derive the sensitivity band from the withstand voltage and the discharge model it was measured with, grade every obliged control on its own band and on how stale its last verification is, refuse a merely dissipative bag where shielding is owed, me...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-protection-diode-esd-sensitivity --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Protection Diode Esd Sensitivity?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-protection-diode-esd-sensitivity)More formats (shields.io, HTML) on the badges page.
---
name: e2008-protection-diode-esd-sensitivity
description: "Use when an ESD-sensitive diode is handled, packed or stored. Assess whether the handling and storage regime applied to an electrostatic-discharge-sensitive protection diode keeps it under the voltage it survives, per ECSS-E-ST-20-08C clause 9.10.2: derive the sensitivity band from the withstand voltage and the discharge model it was measured with, grade every obliged control on its own band and on how stale its last verification is, refuse a merely dissipative bag where shielding is owed, measure the store against a two-sided humidity band whose floor is the ESD limit, and turn residual charge into the volts it delivers with the declared margin applied. Trigger: ecss, e-st-20-08c, clause-9-10-2, protection-diode-esd-sensitivity-band, protection-diode-esd-control-verification-age, protection-diode-terminal-shorting-control, protection-diode-esd-shielding-packaging, protection-diode-esd-storage-humidity-floor."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-08-protection-diode-scope, e2008-protection-diode-esd-sensitivity, e-st-20-08c-clause-9-10-2, protection-diode-esd-sensitivity-band, protection-diode-esd-control-verification-age, protection-diode-terminal-shorting-control, protection-diode-esd-shielding-packaging, protection-diode-esd-storage-humidity-floor]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Protection Diodes -- ESD-Sensitive Handling and Storage (space-systems/ecss/e2008-protection-diode-esd-sensitivity)
Use when the task is clause 9.10.2 of ECSS-E-ST-20-08C: a protection
diode has been found sensitive to electrostatic discharge, and whether
the way it was handled, packed and stored actually kept the voltage it
could see below the voltage it is known to survive.
## Domain quick reference
- Sensitivity is derived, not declared, and it is derived against a named
discharge model. The same withstand voltage places a part in a
different band under a human body model than under a machine model, so
a number quoted without its model places nothing at all.
- A withstand voltage sitting exactly on a band limit belongs to the less
sensitive band, and the comparison absorbs representation error rather
than moving the limit.
- An obliged control is graded three ways, not one. Present is the
weakest of the three: a ground path measured outside its own resistance
band is not a ground path, and a measurement taken long enough ago that
its verification interval has run out no longer says anything about the
bench the part was on today. A wrist strap measured in band eleven
months ago is not a verified wrist strap.
- The obliged set grows with sensitivity, and a discrete diode owes a
control a bonded cell does not: its terminals are shorted together, so
the leads stop being an antenna for a field the package would otherwise
never see. That control is itself graded in a band -- a shorting bar
measuring kilohms is not a short.
- Four passes out of five obliged controls is not a compliant control
set. A control nobody offered is graded absent rather than skipped, or
a regime that owes five and reports four reads as green.
- Shielding and dissipative are different claims, not two grades of one
claim. A dissipative bag bleeds charge off its own surface; it does not
keep an external field off the part inside, so the two sensitive bands
oblige shielding outright.
- The storage envelope is two-sided on both axes, and the humidity FLOOR
is the one an ESD regime exists for. A store that is too humid is a
corrosion problem; a store that is too dry is the ESD problem, because
dry air is what lets ordinary handling build the charge everything else
in the regime is there to bleed away. A ceiling without a floor is half
a check. Shelf life already spent is graded alongside it.
- Residual charge measured on the part is not the finding. The finding is
the voltage that charge delivers across the package capacitance, and a
smaller package capacitance turns the same charge into more volts.
- That voltage is taken against the withstand voltage with the declared
margin applied, so a part that clears the limit only on the nose is
still reported rather than passed.
## Workflow
1. Derive the sensitivity band from the withstand voltage and the
discharge model it was measured with, validating that the threshold
table rises and names every model.
2. Resolve which controls that band obliges, and grade each one on
presence, on its own measured band, and on the age of the measurement
against its verification interval.
3. Grade any control that was never offered as absent rather than
skipping it, and report separately any offered control the band does
not oblige.
4. Grade the packaging against the minimum category the band obliges,
refusing a dissipative bag where shielding is owed.
5. Measure the store against two-sided temperature and humidity bands,
naming which side a reading fell out of, and grade the shelf life
already spent against the declared life.
6. Convert the residual charge and the package capacitance into the
voltage the charge delivers, apply the declared margin factor, and
compare with the withstand voltage under a named tolerance.
7. Report every arm's findings together and call the regime compliant
only when the finding list is empty.
## Pitfalls
- Quoting a withstand voltage without its discharge model. The number on
its own places the part in no band, and the model it came from is what
makes the band mean anything.
- Grading a control as present and stopping. Presence is a third of the
question; the measured value and the age of that measurement are the
other two thirds, and staleness is the one routinely dropped.
- Treating the verification interval as paperwork. A ground path verified
outside its interval is an unverified ground path today, whatever it
measured last year.
- Skipping a control nobody offered. An obliged control absent from the
record is a deficiency, not an omission from the report, and a set that
grades four of five has graded four.
- Accepting a dissipative bag as shielding. Bleeding surface charge and
excluding an external field are different jobs, and only one of them is
what a sensitive part in a stores rack needs.
- Putting a ceiling on humidity and no floor. The dry end is the ESD end;
a one-sided humidity limit passes exactly the store most likely to
charge the part during handling.
- Reporting residual charge as the finding. Charge is not a stress; the
voltage it delivers across the package capacitance is, and a small
package turns a small charge into a large voltage.
- Dropping the margin factor to make a part clear. A part that clears its
withstand voltage only without the declared margin has not cleared it.
- Moving a band limit to pass a reading that sits exactly on it. An
equality at the limit is a representation question, handled by the
tolerance inside the comparison; the declared band stays as declared.
- Reporting a bare rejection. A stale wrist strap, a dissipative bag, a
dry store and an uncleared residual charge each break the regime for a
different reason, and the report names which.
## Behavior contract (gate 3)
The discharge model set and the rising withstand-voltage threshold table
with its project override, the band derivation with an exact limit
falling to the less sensitive band, the per-band obliged control set
including terminal shorting, the three-way control grading on presence,
own band and verification age with absent controls graded rather than
skipped, the packaging ladder and the minimum category per band, the
two-sided temperature and humidity bands with the humidity floor named
and shelf life graded alongside, the charge-to-voltage conversion and its
margin-applied comparison under a named tolerance, and the conjunctive
regime verdict are exercised by the gate 3 contract test:
scripts/test_e2008_protection_diode_esd_sensitivity.py against
scripts/e2008_protection_diode_esd_sensitivity_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2008_protection_diode_esd_sensitivity.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.