Use when a simulator level is being set from primary standards, or an as-run setting has to be defended. Verify that the calibrated reference cells setting a simulator's illumination level satisfy ECSS-E-ST-20-08C clause 10.2.1: confirm each primary standard cites a recognised traceable calibration route and a certificate still valid on the test day, match the single-junction or component standard to the junction it sets, cover every junction of a multijunction article, carry the certificate ...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-primary-standard-cells --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Primary Standard Cells?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-primary-standard-cells)More formats (shields.io, HTML) on the badges page.
---
name: e2008-primary-standard-cells
description: "Use when a simulator level is being set from primary standards, or an as-run setting has to be defended. Verify that the calibrated reference cells setting a simulator's illumination level satisfy ECSS-E-ST-20-08C clause 10.2.1: confirm each primary standard cites a recognised traceable calibration route and a certificate still valid on the test day, match the single-junction or component standard to the junction it sets, cover every junction of a multijunction article, carry the certificate current across to the temperature the standard is actually at, and hold the residual level error inside tolerance with its sign. Trigger: ecss, e-st-20-08c-clause-10-2-1, primary-standard-reference-cell, component-cell-junction-coverage, reference-cell-calibration-validity, simulator-illumination-level-setting, reference-cell-temperature-correction."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-08-photovoltaic-assembly-scope, e2008-primary-standard-cells, primary-standard-reference-cell, component-cell-junction-coverage, reference-cell-calibration-validity, simulator-illumination-level-setting, reference-cell-temperature-correction]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Photovoltaic Assemblies -- Primary Standard Cells (space-systems/ecss/e2008-primary-standard-cells)
Use when the task is clause 10.2.1 of ECSS-E-ST-20-08C -- the calibrated
single junction or component reference cells a simulator's illumination
level is set against, and whether a level set from them can be defended.
## Domain quick reference
- A primary standard is a calibration, not a cell. What makes it primary
is the route the certificate names -- a space-flown, high-altitude
aircraft, balloon or world-radiometric-reference calibration -- so a
reference cell citing a vendor datasheet, or carrying no certificate
reference at all, has a number written on it and nothing behind it.
- The certificate has a life. A standard in date on the day of the test
is what matters, not one that was in date when the campaign was
planned, so the validity is judged against the test date and a
certificate close to lapsing is said aloud while it still passes.
- The junction has to match. A multijunction article is current limited
by whichever junction sees least of its own part of the spectrum, so a
single-junction standard sets one lamp channel and leaves the others
where they happened to be. Every required junction gets a standard
representing it, and a junction with none is named.
- Temperature moves the target, not the reading. The certificate fixes
the short-circuit current at a reference temperature, so the value the
standard should read while it sits warmer or colder is the certificate
value carried across by its own coefficient. Set the lamp to the bare
certificate value at the wrong temperature and the whole coefficient
times the offset lands in the illumination level.
- The residual error is a deliverable, not a leftover. Every performance
measurement taken afterwards inherits it, and it carries a sign: a
level set two per cent high and one set two per cent low bias every
later result in opposite directions.
- A standard offered for a junction nobody asked about is reported as
unused rather than silently counted, because it usually means the
article's junction list and the standards drawer disagree.
## Workflow
1. Validate the standard cell policy first: the level error tolerance,
the certificate validity in days, the window inside which a validity
counts as marginal and the residual error band. A marginal window
wider than the validity itself, or a marginal band wider than the
tolerance, is refused rather than used.
2. Read every offered standard: non-blank identifier, no duplicate
identifier, a named junction, a certificate reference, a calibration
route, an ISO calibration date, a positive calibrated current and a
finite temperature coefficient.
3. Judge traceability before anything else. A standard whose route is
not a recognised primary one, or whose certificate reference is
blank, closes the assessment -- name every such standard, not the
first found.
4. Judge the certificate validity against the test date. A calibration
dated after the test is a record defect and is refused outright; a
lapsed one closes the assessment; one inside the marginal window
passes with an advisory.
5. Match the standards to the junctions the article needs set. A missing
junction closes the assessment; a standard for no required junction
is reported as unused.
6. For each as-set record, carry the certificate current across to the
temperature the standard was at, take the signed level error against
that corrected target, and hold every one inside tolerance.
7. Close on one verdict: traceability not established, calibration
expired, junction coverage incomplete, level out of tolerance, or
level set -- reporting the worst residual error and its sign beside
it.
## Pitfalls
- Setting the lamp so the standard reads its certificate current while
the cell sits well off the reference temperature. It is the single
most common way a correctly calibrated standard produces a wrong
illumination level.
- Setting a multijunction article from one standard. The junctions that
were never set are exactly the ones that can limit the article, and
the setting looks clean because nothing measured them.
- Reading a certificate number as traceability. The route is what makes
the standard primary; the number only identifies the paperwork.
- Judging validity against the planning date. Campaigns slip, and a
certificate that was in date in the schedule is regularly out of date
on the bench.
- Collapsing the residual error into a pass. It has a sign and it biases
every measurement taken afterwards in one direction.
- Comparing a derived error fraction against its tolerance by bare
arithmetic. Both sides are floats that can land a unit in the last
place either side of the bound, so the comparison absorbs that while
the tolerance itself is never relaxed.
## Behavior contract (gate 3)
The policy validation, standard cell record validation with duplicate
rejection, the traceable-route test, the certificate age and validity
against the test date, the marginal validity advisory, the junction
coverage with missing and unused standards, the temperature-corrected
target current, the signed level error, the worst setting and the
illumination verdict are exercised by the gate 3 contract test:
scripts/test_e2008_primary_standard_cells.py against
scripts/e2008_primary_standard_cells_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2008_primary_standard_cells.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.