Verify that a photovoltaic coupon still respects its continuity and output-power limits once humidity exposure has ended, per ECSS-E-ST-20-08C clause 5.5.1.4.5. Use when a post-exposure measurement set must be judged against its pre-exposure baseline: confirm the coupon stabilized for the required recovery period before measurement, correct both illuminated readings back to reference irradiance and cell-temperature so the comparison is between coupon states, not measurement conditions, derive...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-humidity-test-pass-fail-criteria --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Humidity Test Pass Fail Criteria?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-humidity-test-pass-fail-criteria)More formats (shields.io, HTML) on the badges page.
---
name: e2008-humidity-test-pass-fail-criteria
description: "Verify that a photovoltaic coupon still respects its continuity and output-power limits once humidity exposure has ended, per ECSS-E-ST-20-08C clause 5.5.1.4.5. Use when a post-exposure measurement set must be judged against its pre-exposure baseline: confirm the coupon stabilized for the required recovery period before measurement, correct both illuminated readings back to reference irradiance and cell-temperature so the comparison is between coupon states, not measurement conditions, derive the output-power loss fraction and retention ratio, screen every interconnect circuit for an open circuit and for series-resistance increase past its allowance, then aggregate recovery, power and continuity into one verdict. Trigger: ecss, e-st-20-08c, humidity-exposure-pass-criteria, photovoltaic-coupon-continuity, coupon-output-power-retention, interconnect-series-resistance-increase, irradiance-and-temperature-correction, post-exposure-recovery-period, solar-array-coupon-acceptance."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2008-humidity-test-pass-fail-criteria, e-st-20-08c, photovoltaic-coupon-humidity-exposure, coupon-output-power-retention, interconnect-continuity-screening, series-resistance-increase-allowance, irradiance-and-temperature-correction]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Photovoltaic Assemblies — Humidity-Exposure Pass Criteria (space-systems/ecss/e2008-humidity-test-pass-fail-criteria)
Use when the task is the clause 5.5.1.4.5 acceptance decision of
ECSS-E-ST-20-08C: a photovoltaic coupon has come out of its humidity
exposure, and it is admissible only if every interconnect circuit still
conducts and the output power it delivers has not fallen past the
permitted fraction of its pre-exposure value.
## Domain quick reference
- The verdict rests on two conditions, and both are pre-versus-post
comparisons of the same coupon. Continuity: every interconnect circuit
still conducts, and its series resistance has not grown past the
allowance. Output power: the illuminated power delivered after the
exposure retains the required fraction of the power delivered before
it. Neither condition can be read off a single post-exposure number.
- Raw illuminated readings are not comparable. Output power moves with
irradiance almost proportionally and with cell temperature through the
power temperature coefficient, so a pre-exposure reading taken at one
set of conditions and a post-exposure reading taken at another differ
even on an undamaged coupon. Both readings are reported back to
reference irradiance and reference cell-temperature first, and the loss
fraction is formed from the two corrected values.
- Moisture leaving the coupon takes time. A reading taken before the
prescribed stabilization period has elapsed measures the residual
moisture as much as the coupon, so an unrecorded or short recovery
period is a finding against the measurement, independent of whatever
the numbers then say.
- An open circuit and a resistance increase are different findings with
the same root: a degraded interconnect or cell-to-cell joint. An open
circuit has no meaningful increase fraction to report, so it is carried
as its own outcome rather than as an infinite ratio; a circuit that
still conducts but has grown past its allowance is a finding in its own
right and not a partial pass.
- A power reading that comes back higher than the pre-exposure value is a
negative loss. That is admissible against the limit — the condition is
one-sided — but it is reported as what it is rather than clamped to
zero, because a large apparent gain usually points at a measurement or
correction error worth chasing.
## Workflow
1. Check the stabilization period: compare the recovery hours actually
observed before the post-exposure measurement against the required
period. An unrecorded period is a finding, and so is a short one; an
exact equality is compliant.
2. Correct the pre-exposure and the post-exposure illuminated readings to
reference irradiance and reference cell-temperature, using the
coupon's own measured temperature coefficient when it carries one.
Refuse a correction whose temperature factor is not positive rather
than returning a sign-inverted power.
3. Form the output-power loss fraction and the retention ratio from the
two corrected powers, and compare the loss with its permitted value,
absorbing representation error at the boundary with a named tolerance
instead of relaxing the limit.
4. Screen every interconnect circuit. A missing or infinite post-exposure
reading is an open circuit; otherwise form the series-resistance
increase fraction and compare it with the allowance. Reject a
duplicate circuit identifier, a missing key or a non-positive
resistance as an input error.
5. Aggregate the recovery, power and continuity findings into one list.
The coupon is accepted only when that list is empty; report the open
circuit count alongside it so the severity is visible at a glance.
## Pitfalls
- Comparing raw watts across the exposure. Irradiance and cell
temperature differences between the two measurement sessions can
manufacture a loss on an undamaged coupon, or mask a real one; the
correction to reference conditions is what makes the comparison mean
anything.
- Measuring the coupon as soon as the chamber opens. Residual surface
moisture shifts both the resistance readings and the illuminated
power, so the stabilization period is part of the criterion and not
laboratory housekeeping.
- Treating a conducting circuit as a passed circuit. Continuity is not
binary here: a joint that survived as a high-resistance path has lost
margin, and the increase allowance is what catches it before flight.
- Recording an open circuit as an enormous resistance increase. An
infinite ratio pollutes any aggregation of the increase fractions; the
open circuit is carried as its own outcome and counted separately.
- Widening the permitted loss to let an exactly-compliant coupon through.
An equality at the limit is a representation question, handled by the
tolerance inside the comparison; the permitted value stays as
specified.
## Behavior contract (gate 3)
The recovery-period check, the irradiance and temperature correction, the
output-power comparison, the per-circuit continuity screening and the
aggregated verdict are exercised by the gate 3 contract test:
scripts/test_e2008_humidity_test_pass_fail_criteria.py against
scripts/e2008_humidity_test_pass_fail_criteria_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2008_humidity_test_pass_fail_criteria.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.