Use when a blocking diode contact thickness map has to become a weld readiness verdict. Evaluate whether the contact metallisation of a blocking diode is even enough that the interconnector weld made on it later comes out reproducible and adequate, under ECSS-E-ST-20-08C clause 12.6.13: refuse a contact with no declared weld footprint, leave a footprint the map never reached unjudged rather than averaging it into the contact, hold every reading inside the weldable band and each spread against...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-blocking-diode-contact-uniformity --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Blocking Diode Contact Uniformity?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-blocking-diode-contact-uniformity)More formats (shields.io, HTML) on the badges page.
---
name: e2008-blocking-diode-contact-uniformity
description: "Use when a blocking diode contact thickness map has to become a weld readiness verdict. Evaluate whether the contact metallisation of a blocking diode is even enough that the interconnector weld made on it later comes out reproducible and adequate, under ECSS-E-ST-20-08C clause 12.6.13: refuse a contact with no declared weld footprint, leave a footprint the map never reached unjudged rather than averaging it into the contact, hold every reading inside the weldable band and each spread against the mean of its own footprint, and compare the footprint means against one another because a single weld schedule runs on all of them. Trigger: ecss, e-st-20-08c-clause-12-6-13, blocking-diode-weld-footprint-thickness, blocking-diode-interconnector-weld-readiness, blocking-diode-weldable-thickness-band, blocking-diode-footprint-spread-fraction, blocking-diode-weld-schedule-reproducibility, blocking-diode-contact-map-coverage."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-08-photovoltaic-assembly-scope, e2008-blocking-diode-contact-uniformity, blocking-diode-weld-footprint-thickness, blocking-diode-interconnector-weld-readiness, blocking-diode-weldable-thickness-band, blocking-diode-footprint-spread-fraction, blocking-diode-weld-schedule-reproducibility, blocking-diode-contact-map-coverage]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Photovoltaic Assemblies -- Blocking Diode Contact Uniformity (space-systems/ecss/e2008-blocking-diode-contact-uniformity)
Use when the task is the clause 12.6.13 check of ECSS-E-ST-20-08C: the
contact of a blocking diode has been mapped for thickness, and the evenness
of that contact has to be turned into a statement about the interconnector
weld that will be made on it later.
## Domain quick reference
- The evenness is not checked for its own sake. An interconnector will be
welded onto this contact, and a weld schedule is set once and then run on
every joint. The question is whether one schedule will give the same,
adequate weld everywhere it is applied, which is narrower than a general
uniformity question and answers differently.
- Two different evennesses follow from that, and a map reduced to a single
spread figure loses one of them. Inside one footprint the metal under the
electrode has to stay inside the band the schedule was set for. Between
footprints, the means have to agree, because the same schedule serves
them all.
- The band is applied per reading, not to the footprint mean. A footprint
whose readings straddle the band fails even when its mean sits in the
middle of it, because the electrode lands on the metal that is actually
there rather than on the average.
- Too thin and the weld burns through toward the semiconductor; too thick
and the energy never reaches the interface. The failure modes are
opposite, so the floor and the ceiling are both held and a part can
breach either.
- Footprints that each pass their own band can still fail together. A
contact whose first footprint sits near the floor and whose last sits
near the ceiling welds reproducibly nowhere, and that finding is
invisible to a per-footprint check.
- A footprint the map never reached is not a pass. Readings clustered away
from the weld sites describe metal no electrode will touch, so a
footprint carrying fewer readings than the policy asks for closes the
assessment as incomplete rather than being averaged into the contact.
- A reading sitting exactly on a band edge or a spread exactly on its limit
is admissible; the comparison tolerance exists to absorb representation
error rather than to widen the band.
## Workflow
1. Validate the declared weld readiness policy first: the weldable
thickness band, the largest spread admissible inside one footprint, the
advisory band under it, the largest disagreement admissible between
footprint means, and the readings a footprint needs before it can be
judged. A band whose floor is not below its ceiling admits no thickness
and is refused rather than used.
2. Confirm the contact declares its interconnector weld footprints. With
none declared there is nowhere to apply an evenness figure, and the
assessment closes on footprints not established.
3. Validate every mapped reading: a non-blank identifier, a finite
position along the contact and a positive thickness. A contact carrying
no reading is unknown rather than adequate.
4. Take the readings falling inside each footprint, edges included, and
reduce them to count, mean, extremes and the spread against that
footprint mean. Reject a duplicate footprint identifier rather than
grading the same site twice.
5. Grade each footprint against the band per reading and against the spread
limit, naming every reason it missed rather than the first: below the
weld floor, above the weld ceiling, uneven across the footprint.
6. Close on contact map incomplete if any footprint was never mapped
densely enough to grade. A contact part-judged on the footprints that
happened to be covered is not a contact verdict.
7. Take the spread of the footprint means against their own average and
hold it against the reproducibility limit, because one schedule runs on
all of them.
8. Report the worst footprint and its spread beside the verdict, and raise
an advisory for every weldable footprint already at or past the advisory
band. Advisories are reported with the verdict and do not move it.
9. Close on one verdict: weld footprints not established, contact map
incomplete, contact not weld ready, or contact ready for interconnector
welding.
## Pitfalls
- Quoting one spread for the whole contact. It answers the within-footprint
question and the between-footprint question at once and therefore answers
neither, and the schedule that fails is usually the one the second
question would have caught.
- Applying the weldable band to the footprint mean. A site running thin at
one edge and thick at the other averages into the middle of the band and
welds badly at both ends.
- Treating a sparse footprint as even. Three readings in one corner of a
weld site say nothing about the corner the electrode will actually land
on, so coverage is checked before any spread is quoted.
- Mapping the contact away from the weld sites because the probe reaches
there more easily. Metal nobody will weld on is not evidence about the
weld.
- Reporting weld readiness with no worst footprint and no mean spread. The
verdict alone hides the difference between a contact that comfortably
supports one schedule and one that barely does, and the next build has
nothing to compare against.
## Behavior contract (gate 3)
The policy validation, the footprint and reading validation, the selection
of readings inside each footprint with the edges included, the per-reading
band and the spread against the footprint mean, the multi-reason grading,
the unmapped-footprint stop, the disagreement between footprint means, the
worst footprint, the marginal advisories and the closing verdict are
exercised by the gate 3 contract test:
scripts/test_e2008_blocking_diode_contact_uniformity.py against
scripts/e2008_blocking_diode_contact_uniformity_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2008_blocking_diode_contact_uniformity.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.