E2007 Safety Ground Connections

ASecurity

Use when verify that the protective-earth provision presented on an electromagnetic-compatibility bench mirrors the installation practice of the flight build under ECSS-E-ST-20-07C clause 5.2.6.4: categorize the safety-ground provision as protective-earth-terminal, protective-earth-pin, mounting-base-bond or unbonded, confirm the bench provision matches the flight one down to terminal count and earth-pin designation, size the protective-earth conductor adiabatically against prospective fault-...

2 stars
0 votes
0 copies
0 views
Added 9/27/2026
ai-agentspythongo

Works with

claude codeterminalcli

Security Analysis

A100/100

Scanned 9/27/2026

Install to Claude Code

$npx -y skills add ashfordeOU/aero-agent-skills --skill e2007-safety-ground-connections --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of E2007 Safety Ground Connections?

Add the live security badge to your README — it updates automatically with every re-scan.

Security grade badge for E2007 Safety Ground Connections
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/ashfordeou-e2007-safety-ground-connections/badge)](https://www.skillsdirectory.com/skills/ashfordeou-e2007-safety-ground-connections)

More formats (shields.io, HTML) on the badges page.

Download with Pro
Files
SKILL.md
---
name: e2007-safety-ground-connections
description: "Use when verify that the protective-earth provision presented on an electromagnetic-compatibility bench mirrors the installation practice of the flight build under ECSS-E-ST-20-07C clause 5.2.6.4: categorize the safety-ground provision as protective-earth-terminal, protective-earth-pin, mounting-base-bond or unbonded, confirm the bench provision matches the flight one down to terminal count and earth-pin designation, size the protective-earth conductor adiabatically against prospective fault-current and clearing-time, sum the safety-ground path resistance across its segments, and flag a protective-earth conductor shared as a signal-return. Trigger: ecss, e-st-20-07c, protective-earth-terminal, protective-earth-pin, safety-ground-path, fault-current-sizing, earth-conductor-adiabatic, bonding-path-resistance, emc-bench-setup."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
  - id: ecss
    reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
  domain: space-systems
  subdomain: ecss
  tags: [ecss, e-st-20-electrical-scope, e2007-safety-ground-connections, protective-earth-terminal, protective-earth-pin, safety-ground-path, fault-current-sizing, earth-conductor-adiabatic, bonding-path-resistance]
  version: 0.1.0
  author: Aero Agent Skills
---

# ECSS Electromagnetic Compatibility — Safety Ground Connections (space-systems/ecss/e2007-safety-ground-connections)

Use when the task is the protective-earth provision of
ECSS-E-ST-20-07C clause 5.2.6.4 -- showing that the safety-ground
connection a unit is given on an electromagnetic-compatibility bench is
the one the real installation uses, sized for the fault it has to carry
and not doubling as a signal return.

## Domain quick reference

- A safety-ground connection is a fault path, and its job is to hold
  exposed conductive surfaces near the structure potential long enough
  for the upstream protection to clear. That makes it a two-property
  item: it must carry the prospective fault-current for the clearing
  time without melting, and it must present a low enough resistance
  that the touch potential stays bounded while it does so.
- Four provisions are distinguished. A protective-earth-terminal is a
  dedicated stud or lug on the unit housing. A protective-earth-pin is
  a designated contact inside a connector, carried on the harness. A
  mounting-base-bond takes the reference through the unit feet into the
  mounting panel. Unbonded means no provision was declared at all,
  which is a finding rather than a category the bench may choose.
- Mirroring is the whole point of the clause. A bench that improvises a
  crocodile clip onto a housing screw, where the flight build lands on
  a dedicated terminal, changes the fault-path impedance and the
  common-mode current division at the same time, so both the emission
  result and the injected-current distribution stop describing flight.
  Mirroring covers the provision family, the terminal count and the
  earth-pin designation set, not merely the presence of some green
  wire.
- Conductor sizing follows the adiabatic relation: the minimum
  cross-section grows with the fault-current and with the square root
  of the clearing-time, and falls with the material constant of the
  conductor and its insulation. A conductor sized for steady-state
  operating current is routinely too small for the fault it must
  survive.
- The path resistance is the sum over segments -- conductor runs,
  terminal interfaces, connector contact resistance, the strap into the
  bench structure. Segments given as geometry are resolved from
  resistivity, length and cross-section; segments given as a measured
  resistance are taken as measured.
- A protective-earth conductor that also carries a signal-return puts
  return current into the safety path, which both raises the reference
  potential of every circuit sharing it and defeats the fault-detection
  behaviour the path exists for.

## Workflow

1. Categorize the flight safety-ground provision and the bench
   provision from their declared hardware: terminal stud count, earth
   pin designations, or a mounting-base bond. Reject a record that
   declares hardware inconsistently.
2. Compare the two provisions. Flag a family mismatch, a differing
   terminal count and any earth-pin designation present on one side and
   absent on the other.
3. Flag an unbonded provision on either side; that is a missing
   connection, never an acceptable arrangement.
4. Compute the minimum protective-earth conductor cross-section from
   the prospective fault-current, the clearing-time and the material
   constant, then compare the installed cross-section against it.
5. Resolve every segment of the safety-ground path into a resistance
   and sum them, then compare the total against the declared interface
   limit.
6. Flag a protective-earth conductor declared as also carrying a
   signal-return.
7. Aggregate the findings. The provision mirrors the installation only
   when the finding list is empty.

## Pitfalls

- Sizing the protective-earth conductor from the operating current.
  The sizing case is the fault, and the adiabatic relation grows with
  the square root of the clearing-time, so a slow upstream protection
  device can double the required cross-section.
- Accepting any green wire as a mirror of the flight provision. A
  terminal and a connector pin place the fault path in different
  places relative to the unit housing, and swapping one for the other
  moves the common-mode current away from where it flows in flight.
- Summing only the conductor runs and ignoring the interfaces. The
  terminal and contact resistances frequently dominate the total on a
  short bench run, so a path that looks adequate on conductor
  resistance alone can still exceed the interface limit.
- Reading a measured path resistance under the limit as sufficient on
  its own. Resistance and cross-section are independent requirements;
  a thin conductor can measure low and still fail the fault-survival
  case.
- Letting the safety path double as a signal-return because it is
  convenient on the bench. The shared current makes the reference
  potential circuit-dependent and hides exactly the fault the path is
  there to reveal.

## Behavior contract (gate 3)

The provision categorization, installation-mirroring comparison,
adiabatic conductor sizing, path-resistance summation and aggregate
assessment logic is exercised by the gate 3 contract test:
scripts/test_e2007_safety_ground_connections.py against
scripts/e2007_safety_ground_connections_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2007_safety_ground_connections.py

## Compliance

- ECSS standards are freely downloadable (ESA); cite the source and
  paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.

Attribution

ashfordeOUashfordeOU
View sourceMore from ashfordeOU →
SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments (0)

No comments yet. Be the first to comment!

SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Related Skills

Caveman

Ultra-compressed communication mode that cuts output tokens while keeping technical accuracy. Levels: lite, full, ultra and the wenyan variants. Use for /caveman, "caveman mode", "talk like caveman", "be brief" or "less tokens".

1074701 votes

Hyperplan

Adversarial multi-agent planning skill. Self-orchestrates 5 hostile category members (unspecified-low, unspecified-high, deep, ultrabrain, artistry) via team-mode for ruthless cross-critique debate, distills only the defensible insights, then MANDATORILY hands the distilled insight bundle to the `plan` agent for executable plan formalization. Use when planning needs maximum rigor and surfacing of weak assumptions, blind spots, and over-engineering. Triggers: 'hyperplan', 'hpp', '/hyperplan', ...

694821 votes

Mcp Code Execution

Routes multi-tool workflows through MCP servers for large datasets and pipelines. Use when Bash tool overhead is limiting throughput on data-heavy tasks.

3351 votes

catchup

Recovers the conversation and failed tool calls of a previous Codex, Claude Code, Antigravity, Cline, Copilot CLI, Cursor, DeepSeek Harness, Kimi, OpenCode, Pi Agent, or ZCode session. Use when the user says "catch up", "what did the last session do", "get me up to speed", "I switched agents", asks to recover/summarize a previous session before continuing, or asks to diagnose or report a catchup failure. Do NOT use for the current conversation, git history, or any non-agent log.

691 votes

math-skill

A comprehensive mathematical reasoning skill for AI assistants — handles arithmetic to research-level problems with rigorous step-by-step reasoning, systematic verification, and transparent uncertainty handling

381 votes
View all in ai-agents →