Execute and audit one ECSS-E-ST-20-07C clause 5.4.11.4 radiated electric susceptibility run: confirm every radiation-safety provision is in place before the amplifier is keyed, compute the hazard clearance distance the forward power and antenna gain demand against the permissible exposure density, build the geometric step ladder across the declared test frequency range, compare the recorded exposure steps against it to expose skipped stretches and oversized jumps, grade each step dwell agains...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2007-radiated-electric-susceptibility-procedure --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2007 Radiated Electric Susceptibility Procedure?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2007-radiated-electric-susceptibility-procedure)More formats (shields.io, HTML) on the badges page.
---
name: e2007-radiated-electric-susceptibility-procedure
description: "Execute and audit one ECSS-E-ST-20-07C clause 5.4.11.4 radiated electric susceptibility run: confirm every radiation-safety provision is in place before the amplifier is keyed, compute the hazard clearance distance the forward power and antenna gain demand against the permissible exposure density, build the geometric step ladder across the declared test frequency range, compare the recorded exposure steps against it to expose skipped stretches and oversized jumps, grade each step dwell against the response time of the unit under test, and separate findings that stop the run from margins worth carrying. Use when running or reviewing a stepped radiated susceptibility exposure. Trigger: ecss, e-st-20-07c, radiated-electric-susceptibility-procedure, rf-hazard-clearance-distance, stepped-exposure-frequency-ladder, susceptibility-step-dwell-adequacy, radiated-exposure-step-coverage, radiation-safety-provision-check."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2007-radiated-electric-susceptibility-procedure, rf-hazard-clearance-distance, stepped-exposure-frequency-ladder, susceptibility-step-dwell-adequacy, radiated-exposure-step-coverage, radiation-safety-provision-check]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS EMC — Radiated Electric Susceptibility Procedure (space-systems/ecss/e2007-radiated-electric-susceptibility-procedure)
Use when the task is the run sequence of ECSS-E-ST-20-07C clause
5.4.11.4 -- the safety state the chamber has to be in before any power
reaches the antenna, and the stepped walk across the declared frequency
range that follows once it is.
## Domain quick reference
- This is the one EMC method where the hazard is to people rather than
to hardware. The amplifier drives kilowatts into a directional antenna
inside a sealed room, and the field on boresight close in is far above
anything an occupied area may carry. The safety provisions are not
paperwork ahead of the real procedure; they are the first steps of it.
- The hazard clearance distance follows from the drive, not from the
chamber layout. The antenna concentrates the forward power into its
beam, so the density on boresight is the isotropic spread P/(4*pi*d^2)
raised by the gain, and the clearance is the distance at which that
density falls to the permissible exposure limit. Raising the drive by
four pushes the clearance out by two.
- Susceptibility is a fractional-bandwidth effect, so the walk is
geometric: each step sits a fixed fraction above the one below it. A
fixed hertz increment crawls at the bottom of the range and strides
over resonances at the top, which is the opposite of what is wanted.
- The ladder is built by repeated multiplication rather than from a
logarithm count. Library powers and logarithms are not correctly
rounded and disagree in the last bits between hosts, so a ladder
derived from a count can carry a different number of rungs on the
machine that reviews the run than on the one that produced it.
- A pair of neighbouring steps further apart than the allowed fraction
leaves a stretch of the range that was never driven. Nothing in the
record marks that stretch, so it reads as a band the unit survived.
- Dwell is bounded below by what the unit does, not by what the operator
finds tolerable. A fault that takes two seconds to show is invisible to
a one-second step, and the step then records an immunity the unit does
not have.
- A walk finer than the ladder costs chamber time and finds nothing the
ladder misses. It is carried as a limitation, never as a defect.
## Workflow
1. Validate the safety provisions: every one declared, every value a
boolean, no invented provision accepted. An absent provision stops the
run before any frequency is set.
2. Compute the hazard clearance from the forward power, the antenna gain
and the permissible exposure limit, and compare it with the nearest
position that stays occupied while the amplifier is keyed.
3. Validate the declared range: positive start, stop above start, and a
maximum fractional step strictly between nothing and one.
4. Build the step ladder by repeated multiplication, closing it on the
declared stop frequency without duplicating a rung that lands there.
5. Normalize the recorded steps, rejecting a repeated frequency, a
non-positive dwell and a step missing a field, then sort by frequency.
6. Reduce the recorded frequencies against the allowed ratio to expose
oversized jumps and a walk that starts above or stops below the range.
7. Derive the dwell floor from the response time of the unit and the
named minimum, and grade every step dwell against it.
8. Aggregate findings and limitations. The run stands only when no
finding stands.
## Pitfalls
- Treating the safety provisions as a checklist signed before the run
rather than a state held throughout it. The interlock that was armed at
nine o'clock is not evidence about the door at eleven.
- Computing the clearance from the amplifier nameplate rather than the
forward power actually delivered, which is the figure the density
follows.
- Stepping in fixed hertz increments across a wide range, so the bottom
decade is walked pointlessly slowly and the top decade is stepped over.
- Deriving the number of steps from a logarithm and trusting it to match
across hosts. The count is where the rounding difference lands.
- Choosing a dwell from the time budget instead of the response time of
the unit, then reading a quiet step as immunity.
- Rescanning because the walk was finer than the ladder. Redundant steps
cost time; they never lose a stretch of the range.
## Behavior contract (gate 3)
The safety-provision validation, gain conversion, power-density and
hazard-clearance computation, span validation, step-ladder construction,
step-record normalization, coverage reduction, dwell-floor derivation and
run aggregation are exercised by the gate 3 contract test:
scripts/test_e2007_radiated_electric_susceptibility_procedure.py against
scripts/e2007_radiated_electric_susceptibility_procedure_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2007_radiated_electric_susceptibility_procedure.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.