Execute the stepped injection run of a power-lead susceptibility test. Use when the task is ECSS-E-ST-20-07C clause 5.4.7.4 and a supply-lead disturbance has to be applied while the unit is watched for a response: hold the warm up against the longer of a floor and the declared stabilization time, walk the geometric frequency ladder across the band, derive the dwell each step needs from the slowest response the unit can show, ramp the level no more coarsely than the allowance until the require...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2007-power-lead-susceptibility-procedure --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2007 Power Lead Susceptibility Procedure?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2007-power-lead-susceptibility-procedure)More formats (shields.io, HTML) on the badges page.
---
name: e2007-power-lead-susceptibility-procedure
description: "Execute the stepped injection run of a power-lead susceptibility test. Use when the task is ECSS-E-ST-20-07C clause 5.4.7.4 and a supply-lead disturbance has to be applied while the unit is watched for a response: hold the warm up against the longer of a floor and the declared stabilization time, walk the geometric frequency ladder across the band, derive the dwell each step needs from the slowest response the unit can show, ramp the level no more coarsely than the allowance until the required level or the drive limit is reached, and take the lowest responding level as the threshold to margin against the requirement. Refuses a record that recovers above its threshold and a response outside the ramp applied. Trigger: ecss, e-st-20-07c, power-lead-susceptibility-procedure, stepped-injection-ladder, injection-warm-up, injection-step-dwell, susceptibility-threshold-margin, drive-limited-step, level-ramp-coarseness."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e-st-20-07c, e2007-power-lead-susceptibility-procedure, stepped-injection-ladder, injection-step-dwell, susceptibility-threshold-margin, drive-limited-step, level-ramp-coarseness]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Electrical — Power-Lead Susceptibility Injection Procedure (space-systems/ecss/e2007-power-lead-susceptibility-procedure)
Use when the task is the procedure of ECSS-E-ST-20-07C clause 5.4.7.4 --
the warm up that precedes a supply-lead susceptibility run and the stepped
injection carried out afterwards, with the unit watched for a response at
every step.
## Domain quick reference
- The run starts only after the unit has stabilized. The warm up is held
against the LONGER of a general floor and whatever stabilization time
the unit declares for itself: a unit that needs longer than the floor
sets its own requirement, and a unit that needs less still waits the
floor out.
- The frequency ladder is geometric, not linear. Points are spread a
fixed number to the decade, so the ratio between adjacent rungs is
constant and the low end of the band is sampled as finely, in relative
terms, as the high end. A ladder with too few points to the decade
steps straight over a narrow response.
- The ladder has to reach both ends of the band. A run that starts above
the bottom or stops below the top leaves frequencies at which nothing
was injected, and no result covers them.
- The dwell at a step is set by the unit, not by the schedule. It is the
larger of a floor and a multiple of the slowest response the unit can
show, because a response that takes seconds to appear is invisible at a
step held for a fraction of one.
- The level is ramped up to the required level, never applied in one
jump. A coarse rise can pass straight through the level at which the
unit first responds, so the threshold recorded is higher than the real
one and the margin is overstated.
- A ramp may stop early for exactly two reasons: the required level was
reached, or the drive limit of the chain was reached first. A ramp that
stopped short with neither reason declared is an incomplete step, not a
passing one.
- The threshold is the LOWEST level at which the unit responded. A record
in which the unit responds and then recovers at a higher level is a
contradiction in the record, not a second threshold, and it is refused
rather than reported.
- The margin is the threshold measured from the required level, and it
has a requirement of its own. A threshold a decibel above the required
level is above it and still short of the margin.
- A bound met exactly is met. A ratio of two frequencies or a difference
of two levels can land a few units in the last place outside an
exactly-met bound; absorb that in the comparison, never by widening the
bound.
## Workflow
1. Check the warm up against the longer of the floor and the declared
stabilization time, and record which of the two governed.
2. Check the ladder density: points to the decade at or above the
minimum, otherwise report the run as stepping too coarsely.
3. Normalize each injection step: frequency, required level, the ramp of
applied levels, the dwell, the response time, whether the drive limit
was reached and the level any response appeared at. Reject an unknown
key, a missing key, a ramp that does not rise and a response level
outside the ramp that was applied.
4. Check the ramp coarseness at each step and the dwell against what the
response time requires.
5. Where no response appeared, confirm the ramp reached the required
level, or that a drive limit is declared to explain why it did not.
6. Where a response appeared, take the lowest responding level as the
threshold, measure the margin from the required level, and report both
a threshold below the required level and a margin short of its
requirement.
7. Walk the ladder: flag a step that does not advance in frequency and
check every genuine step against the ratio the ladder density allows.
8. Check that the first and last steps reach the bottom and the top of
the band.
9. Aggregate: report the conforming fraction of the steps, the
susceptible count and the drive-limited count, and accept the run only
when no finding remains.
## Pitfalls
- Starting the injection at the floor warm up when the unit declared a
longer stabilization time, which puts the first decade of the run on a
unit that has not settled.
- Spreading the ladder linearly across the band, which oversamples the
top decade and steps over narrow responses at the bottom.
- Holding a fixed short dwell at every step regardless of how slowly the
unit can respond, so a real response appears after the injection has
already moved on.
- Applying the required level in one jump, recording no response, and
reporting a threshold that was never searched for.
- Reading a ramp that stopped short as a pass when no drive limit was
declared to explain the stop.
- Taking the highest responding level, or the level the operator
happened to notice, as the threshold rather than the lowest one.
- Treating a record that recovers at a higher level as a second
threshold; the record contradicts itself and has to be repeated.
- Reporting a threshold above the required level as a pass when the
margin requirement has not been met.
## Behavior contract (gate 3)
The warm-up check, the geometric ladder and its step ratio, the dwell
derived from the response time, the level-ramp coarseness, the
drive-limit and required-level reasoning, the threshold and margin
derivation, the step and profile validation and the whole-run verdict are
exercised by the gate 3 contract test:
scripts/test_e2007_power_lead_susceptibility_procedure.py against
scripts/e2007_power_lead_susceptibility_procedure_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2007_power_lead_susceptibility_procedure.py