Use when verify that a tested unit is arranged in the standard laboratory configuration required by ECSS-E-ST-20-07C clause 5.2.6.1 before emission or susceptibility measurements start: categorize every bench item as tested-unit, support-equipment, interconnecting-harness or coupling-network, check the insulating-standoff height and dielectric, the setback from the reference-plane front edge, the shielded-enclosure wall clearance, the reference-plane area against the unit footprint plus perim...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2007-general-eut-setup --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2007 General Eut Setup?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2007-general-eut-setup)More formats (shields.io, HTML) on the badges page.
---
name: e2007-general-eut-setup
description: "Use when verify that a tested unit is arranged in the standard laboratory configuration required by ECSS-E-ST-20-07C clause 5.2.6.1 before emission or susceptibility measurements start: categorize every bench item as tested-unit, support-equipment, interconnecting-harness or coupling-network, check the insulating-standoff height and dielectric, the setback from the reference-plane front edge, the shielded-enclosure wall clearance, the reference-plane area against the unit footprint plus perimeter-margin, and the exposed harness length and routing height, then hold the run until every geometric non-conformance is closed. Trigger: ecss, e-st-20-electrical-scope, tested-unit-layout, laboratory-configuration, reference-plane-bench, insulating-standoff, harness-routing-geometry, shielded-enclosure-clearance, setup-readiness-gate."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2007-general-eut-setup, tested-unit-layout, laboratory-configuration, reference-plane-bench, insulating-standoff, harness-routing-geometry]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Electrical Test Setup — General Tested-Unit Arrangement (space-systems/ecss/e2007-general-eut-setup)
Use when the task is the ECSS-E-ST-20-07C clause 5.2.6.1 arrangement of a
tested unit in the standard laboratory configuration before an
electromagnetic measurement -- categorizing every item on the bench,
checking the placement geometry against the configuration envelope, and
holding the run while any geometric non-conformance is open.
## Domain quick reference
- Reproducibility across laboratories comes from geometry, not from
instrumentation alone. The same unit measured 100 mm and 400 mm back
from the reference-plane edge, or 50 mm and 200 mm above it, produces
different coupling and different results, so the arrangement is fixed
and recorded before the first reading.
- Every bench item is categorized by its role before it is placed:
exactly one tested unit, support equipment that stimulates, loads or
monitors it, the interconnecting harness, and the coupling networks
feeding the unit. A role outside that set has no defined place in the
standard arrangement and is rejected rather than guessed at.
- The tested unit sits on an insulating standoff of controlled height
above a conductive reference plane. The standoff carries two
requirements, not one: the height band, and a low relative
permittivity so the standoff itself does not load the coupling path.
A relative permittivity below unity is physically impossible and is a
data error, not a good result.
- The reference plane must cover the unit footprint plus a perimeter
margin on all four sides; the required area is the footprint grown by
twice the margin in each direction. A plane smaller than that puts the
plane edge inside the measurement.
- Two distinct clearance families apply: two-sided bands, where the
measured value must sit inside a tolerance around a nominal (standoff
height, front-edge setback, exposed harness length, routing height),
and one-sided floors, where the value must merely reach a minimum
(enclosure wall clearance, item separation).
- The exposed harness run has a nominal length and a nominal height above
the plane; the remainder is stowed. An exposed run longer than the
harness itself is an impossible input and is rejected outright.
## Workflow
1. Categorize the bench: map every item role to tested unit, support
equipment, interconnecting harness or coupling network. Reject an
unrecognized role, a duplicate item name, an empty bench, or a bench
that does not hold exactly one tested unit.
2. Compute the required reference-plane area from the tested-unit
footprint and the perimeter margin, and compare it with the plane
actually available on the bench.
3. Run the two-sided band checks: standoff height, front-edge setback,
exposed harness length and harness routing height, each against its
nominal and tolerance from the arrangement specification.
4. Run the one-sided floor checks: shielded-enclosure wall clearance and
separation between the tested unit and adjacent items.
5. Check the standoff dielectric against the permitted relative
permittivity, independently of the height band.
6. Confirm an interconnecting harness is actually on the arrangement
record; a geometry check that never sees the harness has not checked
the dominant coupling path.
7. Aggregate the findings and emit the gate token. Only an empty finding
list releases the bench for measurement; anything else holds the
setup.
## Pitfalls
- Treating the arrangement as a checklist run after the first sweep. Once
a reading exists, moving the unit to satisfy the geometry invalidates
the reading, so the arrangement is closed first.
- Checking the standoff height and calling the standoff compliant. Height
and dielectric are two independent requirements, and a high-permittivity
block at exactly the right height still changes the coupling.
- Sizing the reference plane to the unit footprint. The margin is needed
on all four sides, so the required area grows by twice the margin in
each direction, not once.
- Confusing a band with a floor. Enclosure wall clearance larger than the
minimum is fine; an exposed harness run longer than nominal is not,
because the harness length sets the coupling length.
- Accepting an exposed harness run longer than the harness. That is a
data-entry error that would otherwise propagate into a negative stowed
length and a silently wrong geometry record.
- Recording only the tested unit and calling the bench categorized. The
support equipment and coupling networks share the plane and set the
separations that the arrangement is supposed to fix.
- Letting a stack-up sum that lands a few units in the last place outside
a band read as a non-conformance. The logic absorbs representation
error with a named tolerance far below any millimetre value; the band
itself is never widened.
## Behavior contract (gate 3)
The bench categorization, band and floor checks, reference-plane sizing,
standoff, harness-routing and readiness-gate logic is exercised by the
gate 3 contract test: `scripts/test_e2007_general_eut_setup.py` against
`scripts/e2007_general_eut_setup_logic.py` (stdlib unittest, offline).
Run: python3 scripts/test_e2007_general_eut_setup.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.