Plan the waveform calibration and the application steps a direct contact discharge run follows, under ECSS-E-ST-20-07C clause 5.4.14.4. Use when the run is written or reviewed: derive the nominal first peak, the thirty and sixty nanosecond currents and the rise time from each charge level, group the calibration as passed, out of tolerance or omitted, reject one older than its validity window, stretch a short interval to the one the generator recharge imposes, require enough discharges at each...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2007-contact-discharge-test-procedure --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2007 Contact Discharge Test Procedure?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2007-contact-discharge-test-procedure)More formats (shields.io, HTML) on the badges page.
---
name: e2007-contact-discharge-test-procedure
description: "Plan the waveform calibration and the application steps a direct contact discharge run follows, under ECSS-E-ST-20-07C clause 5.4.14.4. Use when the run is written or reviewed: derive the nominal first peak, the thirty and sixty nanosecond currents and the rise time from each charge level, group the calibration as passed, out of tolerance or omitted, reject one older than its validity window, stretch a short interval to the one the generator recharge imposes, require enough discharges at each point, order stabilise, calibrate, apply and recover over ascending levels and both polarities, total the discharges and the bench time, and return the plan with its findings. Trigger: ecss, e-st-20-07c, contact-discharge-test-procedure, contact-discharge-waveform-calibration, esd-current-target-first-peak, contact-discharge-application-sequence, esd-generator-recharge-interval, contact-discharge-polarity-coverage."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2007-contact-discharge-test-procedure, contact-discharge-waveform-calibration, esd-current-target-first-peak, contact-discharge-application-sequence, esd-generator-recharge-interval, contact-discharge-polarity-coverage]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS EMC — Contact Discharge Test Procedure (space-systems/ecss/e2007-contact-discharge-test-procedure)
Use when the task is the procedure clause of ECSS-E-ST-20-07C clause
5.4.14.4 -- proving the generator delivers the discharge current
waveform its severity level names, and then applying the discharges to
the unit through the tip in an order that makes the outcome readable.
## Domain quick reference
- The level is a charge voltage; the exposure is a current. Calibrating
into the current target is what ties one to the other: the first peak
and the two decay sample points are read off the target, and each of
them scales linearly with the charge level, so the whole target is
derived from the level rather than looked up run by run.
- The edge matters as much as the peak. An event with the right peak and
a slow rise is a different spectrum, so it is not the event the level
refers to, and an edge outside its band is a finding against the run
rather than a note beside it.
- A calibration has an age. The generator drifts, its tip wears and its
network ages, so a calibration older than its validity window has
stopped describing the machine that delivered these discharges even
though the paper is on file.
- An omitted calibration is not the same failure as a failed one. Nothing
measured means every amplitude rests on the generator's own record,
which is a limitation carried with the results; a measurement outside
tolerance means the run delivered something other than what was asked
for, which is a finding.
- The generator is not a source until it has settled. A high-voltage
supply delivers a drifting charge voltage while it warms, so the
events taken in the first minutes are at a level nobody can name
afterwards -- and they are usually the low-level ones where an upset
would have been most informative.
- The interval is the slowest of three things: what the procedure
declared, how long the generator takes to recharge, and the floor
below which consecutive events stop being separate events. A procedure
declaring something faster is stretched to the slowest, not run as
written.
- Levels ascend and both polarities are applied. Taking the unit to the
top level first destroys the information the lower levels would have
carried, and a single-polarity run covers half the exposure -- which
half being unpredictable in advance.
- A handful of discharges at a point proves nothing. Contact discharge
upset is probabilistic, so the absence of an upset only means
something after enough events at that point, polarity and level, with
somebody watching the unit while they are applied.
## Workflow
1. Validate the run: non-negative dwells, a positive declared interval
and recharge time, a whole number of discharges per point, unique
point labels, recognized polarities and strictly ascending levels.
2. Derive the nominal current target at the calibration level from the
amperes-per-kilovolt coefficients, defaulting them only when the
campaign declares none.
3. Group the calibration as passed, out of tolerance or omitted from the
fractional deviation of each reading, the rise time against its band
and the age against the validity window.
4. Compare the achieved dwell against the dwell the generator needs to
settle.
5. Derive the effective interval as the slowest of the declared one, the
recharge time and the floor, and record whether the declared one had
to be stretched.
6. Check the discharges per point against the minimum and confirm the
unit is watched through the application steps.
7. Build the ordered plan -- stabilise, calibrate when it was run, then
apply at each point for each polarity at each ascending level, then
recover -- and total the discharges and the bench time they occupy at
the effective interval.
8. Aggregate: a short dwell, an out-of-tolerance or expired calibration,
an edge outside its band, a stretched interval, too few discharges
and an unwatched unit are findings; an omitted calibration and a
single polarity are limitations.
## Pitfalls
- Reading the calibration as paperwork. It is what every amplitude in
the report rests on, and skipping it changes the standing of each
number rather than leaving a hole in a file.
- Checking the first peak and never the decay points or the edge. The
peak alone does not make the event the one the level names.
- Treating a calibration certificate as timeless. The window is what
makes it describe this generator on this day.
- Starting the sequence as soon as the generator powers up. The charge
voltage is still moving and the level written in the log is not the
level delivered.
- Setting the repetition from the operator's rhythm. The recharge time
and the floor both govern, and the slowest of the three wins.
- Running the top level first to save bench time. It costs the
information the lower levels would have carried.
- Taking two or three discharges at a point and recording no upset. At
that count the absence of an upset is not evidence of anything.
- Applying the discharges with nobody watching the unit, then reading a
clean log as a clean result.
## Behavior contract (gate 3)
The run validation, level and polarity ordering, nominal current-target
derivation, calibration grouping with its rise-time and validity checks,
stabilisation comparison, effective-interval derivation, discharge-count
and monitoring checks, the ordered step plan, the discharge and bench
time totals and the aggregate verdict are exercised by the gate 3
contract test:
scripts/test_e2007_contact_discharge_test_procedure.py against
scripts/e2007_contact_discharge_test_procedure_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2007_contact_discharge_test_procedure.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.