Use when trace the stray conduction routes of a tethered system under ECSS-E-ST-20-06C clause 10.2.5: build the conduction graph from the intended tether circuit plus every parasitic route through deployment-hardware, enumerate the closed paths that bypass the intended circuit, categorize each bypass by the hardware it crosses (reel-drum, guide-roller, latch-pin, harness-shield, structure-frame), compute its end-to-end path-resistance and the shunted current fraction from the parallel divisio...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2006-unintended-tether-conductive-paths --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2006 Unintended Tether Conductive Paths?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2006-unintended-tether-conductive-paths)More formats (shields.io, HTML) on the badges page.
---
name: e2006-unintended-tether-conductive-paths
description: "Use when trace the stray conduction routes of a tethered system under ECSS-E-ST-20-06C clause 10.2.5: build the conduction graph from the intended tether circuit plus every parasitic route through deployment-hardware, enumerate the closed paths that bypass the intended circuit, categorize each bypass by the hardware it crosses (reel-drum, guide-roller, latch-pin, harness-shield, structure-frame), compute its end-to-end path-resistance and the shunted current fraction from the parallel division against the intended leg, and check each stray route against the isolation-resistance requirement so a bypass through a mechanism is caught before deployment. Trigger: ecss, e-st-20-06c, stray-conduction-path, deployment-hardware-bypass, isolation-resistance, path-resistance, current-division, conduction-graph, tether-circuit-integrity."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2006-unintended-tether-conductive-paths, stray-conduction-path, deployment-hardware-bypass, isolation-resistance, current-division, conduction-graph, tether-circuit-integrity]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Electrical Tether — Unintended Conductive Paths (space-systems/ecss/e2006-unintended-tether-conductive-paths)
Use when the task is the stray-conduction verification of
ECSS-E-ST-20-06C clause 10.2.5 -- proving that the current a tethered
system drives stays inside the intended circuit and does not find a
second route home through the deployer, the guide hardware, a harness
shield or the structure frame.
## Domain quick reference
- The object graded here is a graph, not a component. Nodes are the
electrical nodes of the tethered system (source terminal, tether
end, deployer chassis, structure frame, return terminal); edges are
conduction routes between them, each with a resistance. Edges the
design intends carry the current; every other edge with finite
resistance is a parasitic route, and a bypass exists whenever the
parasitic edges close an alternative path between the same two
terminals as the intended leg.
- A bypass is categorized by the hardware it crosses, because the
mitigation differs. A reel-drum or guide-roller bypass is a rolling
or sliding contact that only conducts once the tether is under
tension; a latch-pin bypass appears at a specific deployment state;
a harness-shield bypass follows a braid that was bonded at both
ends; a structure-frame bypass returns through primary structure.
An unrecognized hardware type is rejected rather than folded into a
generic route.
- Two numbers grade a bypass. Its path-resistance is the series sum of
the edges along it. Its shunted fraction comes from the parallel
division against the intended leg: with the intended resistance Ri
and the bypass resistance Rb in parallel across the same terminals,
the fraction of source current taken by the bypass is
Ri / (Ri + Rb). A high-resistance bypass shunts a negligible
fraction; a bypass comparable to the intended leg takes roughly half
the current and is a circuit-integrity failure, not a nuisance.
- The isolation requirement is a floor, not a target. Every parasitic
edge must measure at least the isolation-resistance minimum on
record for the interface it crosses; an edge below that floor is a
finding regardless of how little current the division says it takes,
because the floor is what keeps the division valid as contacts wear,
wet or gall. A parasitic edge with no isolation minimum on record is
an open finding, not a pass.
## Workflow
1. Build the conduction graph: list every node, then every edge with
its resistance, its intended/parasitic role, and for a parasitic
edge the hardware it crosses and the isolation minimum required at
that interface. Reject a duplicate edge, an unknown node reference
or an unrecognized hardware type before analysis.
2. Enumerate the simple paths between the source terminal and the
return terminal. The path made only of intended edges is the
intended leg; every other path that includes at least one parasitic
edge is a bypass. A graph with no intended leg is rejected as an
incomplete circuit definition.
3. For each path compute the series path-resistance, then for each
bypass compute the shunted current fraction Ri / (Ri + Rb) against
the intended leg resistance.
4. Flag each bypass whose shunted fraction exceeds the allowed
fraction for the design. Treat an exactly-at-limit fraction as
compliant: the comparison absorbs the representation error of a
ratio of sums, and the allowed fraction itself is never widened.
5. Check every parasitic edge against its isolation-resistance
minimum, and flag an edge whose measured resistance falls below the
floor or that carries no floor on record.
6. Aggregate the bypass findings and the isolation findings; the
tethered circuit has integrity only when both lists are empty and
the enumeration found the intended leg.
## Pitfalls
- Checking components for isolation one at a time and never closing
the graph. Isolation is a path property: three interfaces that each
measure acceptably can still form a bypass whose series resistance
is low enough to shunt real current.
- Assuming a mechanism that is open at stowage stays open. A
reel-drum, guide-roller or latch-pin conducts at a particular
deployment state and tension, so the graph is analysed in the state
where the contact is closed, not the state where it is convenient.
- Reading a small shunted fraction as permission to ignore a
sub-floor isolation measurement. The floor guards the division
itself against contact degradation over the mission.
- Bonding a harness shield at both ends without booking the resulting
edge in the graph. A double-bonded braid is a deliberate conduction
route and must be graded as one.
- Treating a parasitic edge with no isolation minimum on record as
compliant by default. An absent requirement is a finding, because
nothing was ever verified against it.
## Behavior contract (gate 3)
The graph-construction, path-enumeration, path-resistance,
current-division, hardware-categorization and isolation-floor logic is
exercised by the gate 3 contract test:
scripts/test_e2006_unintended_tether_conductive_paths.py against
scripts/e2006_unintended_tether_conductive_paths_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2006_unintended_tether_conductive_paths.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.