E2006 Tether High Current Hazards

ASecurity

Use when evaluate the large-current hazards of an electrodynamic-tether circuit under ECSS-E-ST-20-06C clause 10.2.3: categorize every current-carrying segment as tether-conductor, structural-return-path or bonding-strap, compute the ohmic voltage-drop and dissipation each carries at operating current, derive the conductor temperature-rise against its insulation rating, check bonding-joint resistance and rated-current headroom on the structural-return leg, and compare fault let-through-energy...

2 stars
0 votes
0 copies
0 views
Added 9/27/2026
ai-agentspythongo

Works with

claude code

Security Analysis

A100/100

Scanned 9/27/2026

Install to Claude Code

$npx -y skills add ashfordeOU/aero-agent-skills --skill e2006-tether-high-current-hazards --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of E2006 Tether High Current Hazards?

Add the live security badge to your README — it updates automatically with every re-scan.

Security grade badge for E2006 Tether High Current Hazards
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/ashfordeou-e2006-tether-high-current-hazards/badge)](https://www.skillsdirectory.com/skills/ashfordeou-e2006-tether-high-current-hazards)

More formats (shields.io, HTML) on the badges page.

Download with Pro
Files
SKILL.md
---
name: e2006-tether-high-current-hazards
description: "Use when evaluate the large-current hazards of an electrodynamic-tether circuit under ECSS-E-ST-20-06C clause 10.2.3: categorize every current-carrying segment as tether-conductor, structural-return-path or bonding-strap, compute the ohmic voltage-drop and dissipation each carries at operating current, derive the conductor temperature-rise against its insulation rating, check bonding-joint resistance and rated-current headroom on the structural-return leg, and compare fault let-through-energy against the adiabatic conductor withstand so an unprotected path is flagged. Trigger: ecss, e-st-20-06c, electrodynamic-tether, tether-current-hazard, structural-return-path, ohmic-dissipation, bonding-joint-resistance, fault-let-through-energy, conductor-temperature-rise."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
  - id: ecss
    reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
  domain: space-systems
  subdomain: ecss
  tags: [ecss, e-st-20-electrical-scope, e2006-tether-high-current-hazards, electrodynamic-tether, tether-current-hazard, structural-return-path, ohmic-dissipation, bonding-joint-resistance, fault-let-through-energy]
  version: 0.1.0
  author: Aero Agent Skills
---

# ECSS Electrical Tether — High-Current Hazards (space-systems/ecss/e2006-tether-high-current-hazards)

Use when the task is the large-current hazard assessment of
ECSS-E-ST-20-06C clause 10.2.3 -- tracing the current a tethered
system drives along its tether-conductor and back through the
structural-return-path, and checking every segment on that loop for
ohmic-dissipation, temperature-rise, bonding-joint and
fault-withstand violations.

## Domain quick reference

- Clause 10.2.3 is about the whole loop, not the tether alone. An
  electrodynamic-tether drives a current out along the conductor and
  must return it through something: a plasma-contactor lead, a
  deployer slip-ring, a bonding-strap, or -- most often the hazard --
  the spacecraft primary structure acting as a structural-return-path.
  Each segment on that loop is categorized into one of three families
  before it is evaluated: tether (the deployed conductor and its
  shield), return (structure, bonding-strap, chassis bond joint), and
  interface (slip-ring, plasma-contactor lead, deployment-mechanism
  lead). An unrecognized segment type is rejected, not defaulted.
- Every segment is a resistance carrying the loop current, so it
  produces a voltage-drop of I x R and dissipates I^2 x R. The
  dissipation is carried away by the segment's thermal conductance to
  its sink, giving a steady temperature-rise of P / G above the local
  sink temperature. The hazard is not the current itself but the
  resulting conductor temperature against the insulation rating of
  that segment, plus the rated-current headroom of the metal.
- Return-path segments carry two extra checks that tether segments do
  not. First, a bonding joint has a maximum interface resistance; a
  loose or corroded joint concentrates the loop dissipation into a
  millimetre-scale contact and is the classic source of a burned
  structural return. Second, structure sized for mechanical loads is
  not sized for current, so its rated-current headroom must be stated
  explicitly rather than assumed generous.
- Fault behaviour is graded separately from steady operation. A short
  on the loop drives a fault current for the protection device's
  clearing time, depositing a let-through-energy of I^2 x t into the
  conductor. The adiabatic withstand of the conductor is (k x A)^2,
  where k is the material constant and A the metallic cross-section.
  A segment whose let-through-energy exceeds its withstand fuses; a
  segment with no protection device on record is an open finding
  regardless of the arithmetic.

## Workflow

1. Inventory every segment on the current loop -- tether conductor,
   tether shield, structural return, bonding strap, chassis bond
   joint, slip-ring, plasma-contactor lead, deployment-mechanism lead
   -- and categorize each into the tether, return or interface family.
   Reject an unrecognized segment type before it enters the loop.
2. For each segment compute the voltage-drop (I x R) and the
   ohmic-dissipation (I^2 x R) at the declared operating current, then
   the steady temperature-rise (P / G) and the resulting conductor
   temperature above the segment's local sink temperature.
3. Flag the segment when the conductor temperature exceeds the
   insulation rating, when the operating current exceeds the
   rated-current, or when the voltage-drop exceeds the drop allocated
   to that segment. Treat an exactly-at-limit value as compliant --
   the comparison absorbs floating-point representation error rather
   than widening the limit.
4. For every return-family segment additionally check the bonding
   joint: its interface resistance against the maximum on record, and
   the absence of a stated rated-current as a finding in its own
   right, not a pass.
5. For each segment compute the fault let-through-energy from the
   fault current and the clearing time of its protection device, and
   compare it against the adiabatic withstand (k x A)^2. Flag an
   exceedance, and separately flag any segment with no protection
   device on record.
6. Sum the segment voltage-drops around the loop and compare against
   the loop drop budget; the loop is not compliant until the segment
   list, the bonding list and the fault list are all empty.

## Pitfalls

- Grading the tether conductor alone and never modelling the return.
  The return leg is usually the shorter, hotter, less-instrumented
  half of the loop, and a bonding joint on it carries the same current
  through a far smaller contact area.
- Reading "no temperature-rise violation" as thermally safe when the
  thermal conductance was assumed rather than measured. A conductance
  that is optimistic by a factor of two halves every computed rise.
- Treating steady operating current as the sizing case and never
  computing let-through-energy. The adiabatic withstand is fixed by
  cross-section; a clearing time that drifts by a decade moves the
  deposited energy by the same decade.
- Leaving a segment's rated-current or protection device unset and
  scoring it as compliant. An unset value means the requirement was
  never captured, which is a finding, not an absence of one.
- Widening an engineering limit so an exactly-at-limit case passes.
  The limit stays; the comparison is what absorbs the representation
  error of a sum or difference of floats.

## Behavior contract (gate 3)

The segment-categorization, voltage-drop, ohmic-dissipation,
temperature-rise, bonding-joint and fault-let-through-energy logic is
exercised by the gate 3 contract test:
scripts/test_e2006_tether_high_current_hazards.py against
scripts/e2006_tether_high_current_hazards_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2006_tether_high_current_hazards.py

## Compliance

- ECSS standards are freely downloadable (ESA); cite the source and
  paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.

Attribution

ashfordeOUashfordeOU
View sourceMore from ashfordeOU →
SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments (0)

No comments yet. Be the first to comment!

SSkills DirectorySkills Directory

Know which skills are safe — weekly.

Best new skills + every skill we flagged as malicious. From the team that scanned 103,619.

Join free

Related Skills

Caveman

Ultra-compressed communication mode that cuts output tokens while keeping technical accuracy. Levels: lite, full, ultra and the wenyan variants. Use for /caveman, "caveman mode", "talk like caveman", "be brief" or "less tokens".

1074701 votes

Hyperplan

Adversarial multi-agent planning skill. Self-orchestrates 5 hostile category members (unspecified-low, unspecified-high, deep, ultrabrain, artistry) via team-mode for ruthless cross-critique debate, distills only the defensible insights, then MANDATORILY hands the distilled insight bundle to the `plan` agent for executable plan formalization. Use when planning needs maximum rigor and surfacing of weak assumptions, blind spots, and over-engineering. Triggers: 'hyperplan', 'hpp', '/hyperplan', ...

694821 votes

Mcp Code Execution

Routes multi-tool workflows through MCP servers for large datasets and pipelines. Use when Bash tool overhead is limiting throughput on data-heavy tasks.

3351 votes

catchup

Recovers the conversation and failed tool calls of a previous Codex, Claude Code, Antigravity, Cline, Copilot CLI, Cursor, DeepSeek Harness, Kimi, OpenCode, Pi Agent, or ZCode session. Use when the user says "catch up", "what did the last session do", "get me up to speed", "I switched agents", asks to recover/summarize a previous session before continuing, or asks to diagnose or report a catchup failure. Do NOT use for the current conversation, git history, or any non-agent log.

691 votes

math-skill

A comprehensive mathematical reasoning skill for AI assistants — handles arithmetic to research-level problems with rigorous step-by-step reasoning, systematic verification, and transparent uncertainty handling

381 votes
View all in ai-agents →