E2006 Grounding Verification By Inspection

ASecurity

Use when verify that a spacecraft bonding-and-grounding provision is closed under ECSS-E-ST-20-06C clause 6.8.1 through inspection evidence combined with an electrical continuity measurement: categorize each provision as a structure-bond, equipment-chassis-bond, harness-shield-termination or static-dissipative-bleed-path, confirm the inspection record carries surface-preparation, fastener-installation, corrosion-protection and conductor-routing evidence with no open nonconformance, check the ...

  • 2 stars
  • 0 votes
  • 0 copies
  • 5 views
  • Added September 27, 2026
ai-agentspythongotestinggit

Works with

  • claude code

Security analysis

A100/100

Pro scans all 3 files and shows the line behind each finding

Scanned September 27, 2026

npx -y skills add ashfordeOU/aero-agent-skills --skill e2006-grounding-verification-by-inspection --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of E2006 Grounding Verification By Inspection?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for E2006 Grounding Verification By Inspection
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/ashfordeou-e2006-grounding-verification-by-inspection/badge)](https://www.skillsdirectory.com/skills/ashfordeou-e2006-grounding-verification-by-inspection)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: e2006-grounding-verification-by-inspection
description: "Use when verify that a spacecraft bonding-and-grounding provision is closed under ECSS-E-ST-20-06C clause 6.8.1 through inspection evidence combined with an electrical continuity measurement: categorize each provision as a structure-bond, equipment-chassis-bond, harness-shield-termination or static-dissipative-bleed-path, confirm the inspection record carries surface-preparation, fastener-installation, corrosion-protection and conductor-routing evidence with no open nonconformance, check the dc-bond-resistance reading was taken four-wire on an instrument that resolves the applicable bound, compare it against the per-category resistance bounds, and close the provision only when both halves pass and the network carries a structure-bond reference point. Trigger: ecss, e-st-20-06c, clause-6-8-1, grounding-provision-verification, bonding-continuity-inspection, dc-bond-resistance, four-wire-continuity-measurement, bond-strap-inspection-record, shield-termination-continuity, electrical-bonding-evidence."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
  - id: ecss
    reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
  domain: space-systems
  subdomain: ecss
  tags: [ecss, e-st-20-electrical-scope, e2006-grounding-verification-by-inspection, grounding-provision-verification, bonding-continuity-inspection, dc-bond-resistance, shield-termination-continuity, four-wire-continuity-measurement]
  version: 0.1.0
  author: Aero Agent Skills
---

# ECSS Electrical — Grounding Verification by Inspection (space-systems/ecss/e2006-grounding-verification-by-inspection)

Use when the task is the verification closure of ECSS-E-ST-20-06C clause
6.8.1 -- confirming that a bonding or grounding provision has both the
inspection evidence and the electrical continuity measurement on record
before it is declared verified.

## Domain quick reference

- Clause 6.8.1 makes verification a two-part obligation. Inspection
  alone proves a bond was built as drawn but not that it conducts;
  a continuity reading alone proves conduction at one instant but not
  that the joint was prepared, fastened and protected so it stays
  conductive. Neither half closes the provision on its own.
- Each provision is categorized before any bound applies. A
  structure-bond (face-to-face joint into primary structure) carries
  the tightest dc-bond-resistance bound; an equipment-chassis-bond and
  a harness-shield-termination carry progressively looser bounds; a
  static-dissipative-bleed-path is bounded on both sides -- too low is
  a short across the isolation, too high stops the surface bleeding.
  An uncategorized provision must never inherit a neighbouring
  category's bound.
- The inspection half records four attributes: surface-preparation
  (mask, finish, oxide removal at the mating faces), fastener-
  installation (correct hardware, washers, torque), corrosion-
  protection (sealing or finish restored after bonding) and
  conductor-routing (strap length, slack, bend radius). Only
  conductor-routing may be not-applicable, and only on a face-to-face
  structure-bond that has no strap.
- The electrical half is quality-gated, not just a number. A
  milliohm-level bound demands a four-wire dc reading -- a two-wire
  reading buries the joint in lead resistance -- and the instrument
  resolution must resolve the bound to at least one part in ten. A
  reading taken with an instrument that cannot resolve the bound is
  not evidence at any value.
- Network level: the bonds are measured against a reference. A
  dossier with no structure-bond reference point stays open even when
  every individual provision passes.

## Workflow

1. Categorize every provision in the dossier (structure-bond,
   equipment-chassis-bond, shield-termination, static-dissipative-
   bond), rejecting an unrecognized provision kind rather than
   defaulting it.
2. Evaluate the inspection record: all four attributes verified, the
   not-applicable state allowed only for conductor-routing on a
   face-to-face bond, and zero open nonconformances against the
   provision.
3. Evaluate the continuity measurement: method adequate for the
   bound, instrument resolution at or finer than one tenth of the
   bound, and the reading inside the category's lower/upper bounds.
4. Compute the fractional margin to the upper bound so a provision
   that passes with almost no margin is visible for retest after
   environmental exposure.
5. Close the provision only when both halves are clean; otherwise
   report it open with the inspection and continuity findings kept
   separate so the retest scope is unambiguous.
6. Roll up to the network: report open provisions, duplicate provision
   ids and a missing structure-bond reference point; the network is
   closed only when all three lists are empty.

## Pitfalls

- Accepting a continuity reading as full verification -- the clause
  pairs inspection with electrical testing, and a joint measured
  conductive over unprepared or unprotected faces will drift once it
  corrodes or relaxes.
- Reading a milliohm-level bond two-wire: the test-lead and contact
  resistance is of the same order as the bound itself, so the reading
  grades the leads, not the joint.
- Using an instrument whose resolution is coarse relative to the
  bound and treating the displayed value as a pass -- a reading that
  cannot resolve the bound carries no verification content whatever
  it displays.
- Marking surface-preparation or corrosion-protection not-applicable
  to clear a record; only conductor-routing has a legitimate
  not-applicable case, and only on a bond with no strap.
- Treating a static-dissipative-bleed-path as pass-if-low. It is
  bounded below as well as above; a near-short defeats the isolation
  the bleed path was added to preserve.
- Declaring the network verified from per-provision passes alone
  while no structure-bond reference point exists to measure against.

## Behavior contract (gate 3)

The categorization, inspection-record, continuity-measurement, margin
and network-closure logic is exercised by the gate 3 contract test:
scripts/test_e2006_grounding_verification_by_inspection.py against
scripts/e2006_grounding_verification_by_inspection_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e2006_grounding_verification_by_inspection.py

## Compliance

- ECSS standards are freely downloadable (ESA); cite the source and
  paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.

Files in this skill

  • SKILL.md6.5 KB
  • scripts/e2006_grounding_verification_by_inspection_logic.py11.1 KB
  • scripts/test_e2006_grounding_verification_by_inspection.py14 KB

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

View all in ai-agents →

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.