Use when verify that a multipactor test bed meets the minimum configuration conditions of ECSS-E-ST-20-01C clause 8.2 before an article is installed: categorize every bed element as vacuum-system, rf-chain, instrumentation, electron-seeding or detection-method; confirm the chamber reaches the required vacuum-pressure-level with pump-down and bake-out on record; check each measurement instrument carries an in-date calibration-certificate covering the planned run date; size the rf-chain so the ...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2001-test-bed-configuration --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2001 Test Bed Configuration?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2001-test-bed-configuration)More formats (shields.io, HTML) on the badges page.
---
name: e2001-test-bed-configuration
description: "Use when verify that a multipactor test bed meets the minimum configuration conditions of ECSS-E-ST-20-01C clause 8.2 before an article is installed: categorize every bed element as vacuum-system, rf-chain, instrumentation, electron-seeding or detection-method; confirm the chamber reaches the required vacuum-pressure-level with pump-down and bake-out on record; check each measurement instrument carries an in-date calibration-certificate covering the planned run date; size the rf-chain so the source rating covers the maximum applied-power raised by the required run-margin in decibels; and confirm at least one global and one local multipactor-detection method plus an electron-seeding source are present. Trigger: ecss, e-st-20-01c, multipactor-test-bed, vacuum-pressure-level, calibration-certificate, calibrated-instrumentation, rf-chain-capability, electron-seeding-source, detection-method-coverage, test-bed-configuration."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2001-test-bed-configuration, multipactor-test-bed, vacuum-pressure-level, calibrated-instrumentation, electron-seeding-source, detection-method-coverage]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Multipactor -- Test Bed Minimum Configuration (space-systems/ecss/e2001-test-bed-configuration)
Use when the task is establishing that a multipactor test bed satisfies the
minimum conditions of ECSS-E-ST-20-01C clause 8.2 -- the vacuum-pressure-level
the chamber holds, the calibration state of every measurement instrument, the
rf-chain headroom above the maximum applied-power, the electron-seeding source
and the multipactor-detection coverage -- before any article is mounted in it.
## Domain quick reference
- A multipactor test bed is only admissible when its own environment cannot
mask or mimic the effect under investigation. Clause 8.2 therefore fixes a
floor on five element families, and a bed element that belongs to none of
them is outside the configuration record: vacuum-system (chamber, pumps),
rf-chain (source, amplifier, circulator, coupler, load), instrumentation
(power-meter, spectrum-analyser, network-analyser, vacuum-gauge,
residual-gas-analyser, thermocouple), electron-seeding (ultraviolet lamp,
radioactive source, electron gun) and detection-method.
- The vacuum-pressure-level matters because the discharge physics changes with
residual gas: above the free-molecular threshold a gas discharge can ignite
and be mistaken for a resonant-electron event, so the bed must pump below the
required level and hold it. Pump-down alone is not the condition; bake-out or
an equivalent outgassing treatment is what keeps the level stable while
radio-frequency power is applied.
- Every instrument that produces a number entering the verdict carries a
calibration-certificate with a due date. The admissible question is not
whether a certificate exists but whether it is still in date on the planned
run date, computed against that date, not against today.
- The rf-chain is sized from the maximum applied-power and the run-margin the
test specification requires above it. The margin is stated in decibels, so
the required source rating is the applied-power scaled by ten raised to the
margin over ten; comparing watts against decibels directly is the classic
sizing error.
- Detection is split into global methods, which observe the whole device
(forward and reverse power nulling, third-harmonic emission, close-to-carrier
noise, phase-noise), and local methods, which observe the gap directly
(electron probe current). A bed carrying two global methods and no local one
has redundancy but no independence: clause 8.2 coverage needs at least one of
each family.
## Workflow
1. Categorize every element in the bed record into one of the five families.
An unrecognized element type is rejected before the assessment continues --
it means the record and the hardware have drifted apart.
2. Check the vacuum condition: measured chamber pressure at or below the
required level, and an outgassing treatment (bake-out or equivalent) on
record. A measured pressure that sits on the limit within numerical
tolerance is compliant; a missing bake-out entry is a finding even when the
pressure reads well below the limit.
3. For each measurement instrument, compute the days remaining between the
planned run date and the calibration due date. Zero days remaining is still
in date; a negative value is an expired certificate and a finding naming
that instrument.
4. Size the rf-chain: required source rating equals maximum applied-power times
ten raised to the run-margin over ten. Compare the installed source rating
against it, treating an exact-limit rating as sufficient.
5. Check the electron-seeding family: at least one seeding source is present
and its emission is directed into the device gap region. A seeding source
listed but marked inactive does not satisfy the condition.
6. Check detection coverage: at least one global and at least one local
multipactor-detection method, each mapped to an instrument that is itself
in calibration. A detection method resting on an expired instrument is not
counted.
7. Aggregate the findings. The bed is configuration-compliant only when every
check above returns empty; the aggregate reports which family failed so the
bed can be repaired rather than re-run blind.
## Pitfalls
- Reading a low gauge pressure as a satisfied vacuum condition while the
bake-out record is absent -- the chamber walls reload the volume once
radio-frequency power heats them, and the level drifts up during the run.
- Checking calibration against the date the record was written rather than the
planned run date -- a certificate that expires between the two reads as valid
and the run produces uncalibrated numbers.
- Adding the run-margin in decibels to a power in watts, or comparing a watt
rating against a decibel margin -- the margin is a ratio and must be applied
multiplicatively before any comparison.
- Counting two global detection methods as coverage -- both families see the
same aggregate signature, and a local probe is what discriminates a genuine
gap discharge from an rf-chain artefact.
- Treating a listed but inactive electron-seeding source as present -- without
free electrons in the gap the onset power observed is the statistical
delay, not the physical threshold, and the bed reports an optimistic result.
## Behavior contract (gate 3)
The element-categorization, vacuum-readiness, calibration-validity, rf-chain
sizing, electron-seeding and detection-coverage logic is exercised by the
gate 3 contract test: scripts/test_e2001_test_bed_configuration.py against
scripts/e2001_test_bed_configuration_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e2001_test_bed_configuration.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.