Use when verify that the airborne-particle cleanliness required for multipactor-sensitive RF-hardware is held through assembly, multipactor-testing, delivery and hardware-handling under ECSS-E-ST-20-01C clause 6.1: convert each declared cleanroom-class into a monitored concentration-limit at the sampled particle-size, grade measured airborne-counts against that limit, confirm every lifecycle-phase declares a regime no coarser than the hardware requirement, estimate particulate fall-out onto t...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2001-multipactor-test-cleanliness --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2001 Multipactor Test Cleanliness?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2001-multipactor-test-cleanliness)More formats (shields.io, HTML) on the badges page.
---
name: e2001-multipactor-test-cleanliness
description: "Use when verify that the airborne-particle cleanliness required for multipactor-sensitive RF-hardware is held through assembly, multipactor-testing, delivery and hardware-handling under ECSS-E-ST-20-01C clause 6.1: convert each declared cleanroom-class into a monitored concentration-limit at the sampled particle-size, grade measured airborne-counts against that limit, confirm every lifecycle-phase declares a regime no coarser than the hardware requirement, estimate particulate fall-out onto the exposed critical-gap surfaces over the dwell, and report the containment-controls a phase has not declared. Trigger: ecss, e-st-20-01c, multipactor-test-cleanliness, airborne-particle-count, cleanroom-class-limit, particulate-fall-out, containment-controls, critical-gap-surface."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e2001-multipactor-test-cleanliness, multipactor-test-cleanliness, airborne-particle-count, cleanroom-class-limit, particulate-fall-out, critical-gap-surface]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Multipactor Design and Test — Test Cleanliness (space-systems/ecss/e2001-multipactor-test-cleanliness)
Use when the task is the airborne-particle cleanliness control of
ECSS-E-ST-20-01C clause 6.1 -- holding the required particulate regime
across assembly, multipactor-testing, delivery and hardware-handling so
that the critical-gap region of an RF-item is not seeded with the
particles that trigger a premature multipactor discharge.
## Domain quick reference
- A cleanroom-class is a concentration ceiling, not a label. The class
fixes the permitted airborne count at a reference particle-size and
the ceiling falls off as the sampled size grows; a count is graded
against the ceiling recomputed at the size actually sampled, never
against the class number itself. A numerically larger class is the
coarser (dirtier) room, so a phase satisfies a requirement when its
class is at most the required class.
- Clause 6.1 spans the whole lifecycle, not the test bay alone. Four
phases carry the regime: assembly, multipactor-testing, delivery and
hardware-handling. Each declares its own class and its own
containment controls (garment discipline, filtered-air supply,
particle monitoring, chamber purge, double-bagging, purge-gas fill,
seal records, tool-cleanliness records). The end-to-end regime is
only as good as its coarsest declared phase, and a phase with no
declaration is a gap, not a pass.
- Airborne concentration becomes a surface problem through fall-out.
Particles settle at a near-constant speed in still air, so the count
deposited per unit area over a dwell is concentration x settling
speed x dwell, and the obscuration each particle contributes is the
area of its own projected disc. That obscuration is what the
critical-gap allowance is written against; the airborne number alone
does not answer whether the gap is acceptable after a long exposure.
- A particle bridging or partly bridging the critical gap lowers the
local breakdown threshold and seeds free electrons, which is why the
cleanliness requirement is a multipactor requirement and not only a
workmanship one.
## Workflow
1. Capture the hardware cleanliness requirement as a class plus the
particle-size the programme samples at, and recompute the
concentration ceiling at that size.
2. Collect the class declared for each of the four lifecycle phases,
normalising phase aliases (integration to assembly, shipment to
delivery, storage to hardware-handling). Reject an unrecognised
phase and reject the same phase declared twice under two aliases.
3. Grade each phase's measured airborne count against the ceiling for
that phase's own declared class. Treat a count equal to the ceiling
as compliant.
4. Flag every phase declaring a class coarser than the requirement and
every phase with no declaration at all.
5. Estimate fall-out onto the exposed critical-gap surface over the
dwell the item actually spends open, and compare the resulting
obscuration against the allowance.
6. For each phase, difference the declared containment controls
against the controls that phase requires, and report the gaps.
7. Aggregate: the programme is not clause 6.1 compliant until the
class profile, the counts, the fall-out estimate and the control
declarations are all clear.
## Pitfalls
- Comparing a measured count against the ceiling for the reference
particle-size when the programme samples at a larger size -- the
ceiling is size-dependent and using the reference value passes
counts that are several times over the real limit.
- Reading a larger class number as a stricter room. The ordering is
inverted: the requirement is an upper bound on the class number.
- Grading only the test bay and crediting the whole lifecycle. Delivery
and hardware-handling routinely dominate the accumulated fall-out
because they last far longer than the chamber time.
- Treating a clean airborne number as a clean surface. A modest
concentration held over a multi-day dwell can still exceed the
critical-gap obscuration allowance; the dwell is part of the check.
- Letting an exact-boundary count read as a violation. A ceiling built
from a power of ten and a count reassembled from partial samples can
differ by a few units in the last place, so the comparison absorbs
the representation error rather than widening the ceiling.
- Recording containment controls as free text and never differencing
them against the required set -- an undeclared control is a finding
in its own right, independent of any measured count.
## Behavior contract (gate 3)
The concentration-ceiling, measurement-grading, phase-profile,
fall-out and containment-control logic is exercised by the gate 3
contract test: `scripts/test_e2001_multipactor_test_cleanliness.py`
against `scripts/e2001_multipactor_test_cleanliness_logic.py`
(stdlib unittest, offline). Run:
python3 scripts/test_e2001_multipactor_test_cleanliness.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.