Use when verify that a spacecraft electrical power subsystem covers its five core functions under ECSS-E-ST-20C clause 5.2.2.1: map every declared element (solar-array, regulator, battery, distribution unit, sensor) onto the generation, conditioning, storage, distribution and monitoring functions it performs, flag any core function left without an element, confirm every energy-carrying element is observable in telemetry, check redundancy unless a single-string architecture is explicitly accep...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e20-power-subsystem-core-functions --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E20 Power Subsystem Core Functions?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e20-power-subsystem-core-functions)More formats (shields.io, HTML) on the badges page.
---
name: e20-power-subsystem-core-functions
description: "Use when verify that a spacecraft electrical power subsystem covers its five core functions under ECSS-E-ST-20C clause 5.2.2.1: map every declared element (solar-array, regulator, battery, distribution unit, sensor) onto the generation, conditioning, storage, distribution and monitoring functions it performs, flag any core function left without an element, confirm every energy-carrying element is observable in telemetry, check redundancy unless a single-string architecture is explicitly accepted, and compute the power delivered to the loads through the conditioning and distribution efficiencies. Flags an unallocated core function, an unobservable element, an uncategorized element type and an undeclared single-string function. Trigger: ecss, e-st-20-electrical-scope, power-subsystem-core-functions, power-generation-function, power-conditioning-function, energy-storage-function, power-distribution-function, power-monitoring-function."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e20-power-subsystem-core-functions, power-generation-function, power-conditioning-function, energy-storage-function, power-distribution-function, power-monitoring-function]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Electrical Engineering — Power Subsystem Core Functions (space-systems/ecss/e20-power-subsystem-core-functions)
Use when the task is proving that an electrical power subsystem
actually performs what ECSS-E-ST-20C clause 5.2.2.1 requires of it --
generating, conditioning, storing, distributing and monitoring the
spacecraft's energy -- by tracing each of those five capabilities down
to declared elements rather than to an architecture diagram.
## Domain quick reference
- Clause 5.2.2.1 is written in terms of capability, not hardware. It
names five functions the subsystem must perform: generation (turning
a primary source into electrical power), conditioning (regulating
that raw output onto a usable bus), storage (holding energy so the
bus survives eclipse, launch and any period without generation),
distribution (routing power to the consumers with protection), and
monitoring (making the state of the whole chain observable in
telemetry). An architecture satisfies the clause only when every one
of the five traces to at least one real element.
- Elements and functions are many-to-many. A solar array performs one
function; a combined conditioning and distribution unit performs
three; a fuel cell both generates and stores. Mapping one element to
exactly one function is the most common way a real gap gets hidden,
because the combined unit is booked against distribution and its
conditioning role is then assumed to be someone else's.
- Monitoring is a function over the other four, not a peer of them.
Every element that carries energy -- generating, conditioning,
storing, distributing -- has to be observable, and the check is
whether a monitoring element reports it, not whether a sensor exists
somewhere in the subsystem. A purely monitoring element is the
observer and is not itself an object of this check.
- Redundancy is an architectural decision, not an automatic
requirement. A function carried by exactly one element is a real
risk concentration, so it is flagged unless single-string operation
for that function has been explicitly accepted and recorded. Silence
is not acceptance.
- The chain is lossy end to end. Power reaching the loads is the
generated power through the conditioning efficiency and then the
distribution efficiency; quoting source output as though it were
load-available power overstates the subsystem by the whole
conversion loss.
## Workflow
1. Declare every subsystem element as an identifier plus an element
type. Reject an uncategorized type before it enters the review -- an
unmapped element contributes no function and silently leaves a gap.
2. Build the coverage map: for each element, add its identifier under
every core function its type performs. Reject a blank or duplicated
identifier, which would double-count a unit.
3. List the core functions with no element and raise one finding per
unallocated function.
4. For each covered function carried by exactly one element, check the
accepted single-string list; raise a finding when the function is
not on it.
5. For each energy-carrying element, check it appears in the monitored
set; raise a finding for any that does not. Reject a monitored
identifier that is not a declared element -- it points at telemetry
for hardware the subsystem does not have.
6. Compute the delivered power: generated power x conditioning
efficiency x distribution efficiency, and the conversion loss
against the generated figure.
7. Aggregate the allocation, redundancy and monitoring findings; the
subsystem is not clause-5.2.2.1 compliant until all three lists are
empty.
## Pitfalls
- Reading a populated block diagram as coverage. The clause is
satisfied by elements that perform the function, and a diagram with
a labelled box but no declared element leaves the function
unallocated.
- Booking a multi-function unit against a single function, then
treating the others as covered. The conditioning and distribution
unit performs both; mapping it to distribution alone makes a real
conditioning gap invisible.
- Counting a sensor's presence as monitoring coverage. Coverage is
per element observed, not per sensor owned -- a subsystem with two
current sensors and an unreported battery still has an unobservable
energy store.
- Treating an undiscussed single-string function as accepted. The
finding exists so the risk is recorded and signed, and clearing it
requires a decision, not an omission.
- Quoting generated power as available power. The conditioning and
distribution efficiencies are multiplicative, so a 0.90 and 0.95
chain returns about 85% of source output to the loads and the
missing 15% is real dissipation the thermal design has to take.
## Behavior contract (gate 3)
The element-to-function mapping, coverage, allocation, redundancy,
monitoring-observability and chain-efficiency logic is exercised by
the gate 3 contract test:
scripts/test_e20_power_subsystem_core_functions.py against
scripts/e20_power_subsystem_core_functions_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e20_power_subsystem_core_functions.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.