"Use when verify and validate interfaces under ECSS-E-ST-10-24C §5.6:
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e1024-verif --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E1024 Verif?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e1024-verif)More formats (shields.io, HTML) on the badges page.
---
name: e1024-verif
description: "Use when verify and validate interfaces under ECSS-E-ST-10-24C §5.6:
check each ICD record for completeness (required fields, valid interface type,
non-self-referential subsystems), confirm every VCD entry carries an approved
verification method per E-ST-10-02 (test, analysis, inspection, review, or
similarity) and a recognized status, trace each interface requirement to at
least one VCD entry to identify coverage gaps, and flag interface items with
no verification record. Trigger: ecss, e-st-10-system-scope, e-st-10-24c,
interface-verification, icd, vcd, verification-control-document,
interface-compliance, coverage-trace."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-10-system-scope, e-st-10-24c, interface-verification, icd, vcd, verification-control-document, interface-compliance]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Interface Management — Verify and Validate Interfaces (space-systems/ecss/e1024-verif)
Use when the task is to verify and validate interface definitions under
ECSS-E-ST-10-24C §5.6 — checking ICD records for completeness, validating
VCD entries for approved methods and statuses, and tracing every interface
requirement to at least one verification activity.
## Domain quick reference
- ECSS-E-ST-10-24C §5.6 requires that every interface defined in an ICD
is covered by a corresponding entry in the Verification Control Document
(VCD). Each VCD entry names an approved verification method and records
the current status of that verification activity.
- Approved verification methods (per E-ST-10-02): test, analysis,
inspection, review, and similarity. Any other method string is not
recognized and must be flagged before the VCD is accepted.
- Recognized VCD statuses: open, in-progress, complete, waived,
not-applicable. A waived entry must still appear in the VCD — the
waiver decision is evidence, not an absence of coverage.
- An ICD record must have: a unique identifier, a source subsystem, a
destination subsystem, a recognized interface type (mechanical,
electrical, thermal, data, rf, optical, fluid, or software), and a
description. Source and destination must be distinct subsystems — a
self-referential interface (source equals destination) cannot be
verified meaningfully and is flagged.
- Coverage gap: an ICD item with no matching VCD entry (by ICD ID) is a
gap finding. Coverage ratio = number of ICD items with at least one
VCD entry divided by total ICD items.
## Workflow
1. Inventory all ICD records for the interface set under review. Confirm
each record carries all required fields: id, source_subsystem,
destination_subsystem, interface_type, and description. Flag any
record missing a field or carrying a blank value.
2. Check each ICD record's interface_type against the recognized set.
Flag any unrecognized type. Check that source_subsystem and
destination_subsystem are not identical; flag any self-referential
pair.
3. Inventory all VCD entries. Confirm each entry carries: id, icd_ref
(pointing to the ICD record ID it covers), method, and status. Flag
any entry with a missing or blank required field.
4. Validate each VCD entry's method against the approved set. Validate
the status against recognized statuses. Flag any entry that fails
either check.
5. Trace each ICD record to VCD entries: for every ICD id, check whether
at least one VCD entry exists with a matching icd_ref. Collect ICD
ids with no matching VCD entry as gap findings.
6. Compute the coverage ratio. Report: ICD findings, VCD findings,
coverage gaps, coverage ratio, and overall compliance status. The
interface set is compliant only when ICD findings, VCD findings, and
gaps are all empty.
## Pitfalls
- Treating a waived VCD entry as a gap — a waived status still provides
evidence of a deliberate disposition; the gap list should only include
ICD items with no VCD entry at all.
- Accepting an unrecognized verification method without flagging it —
a method outside the E-ST-10-02 approved set cannot be evaluated for
rigor; it must be flagged, not silently passed.
- Reading zero findings from a short ICD list as "fully verified" before
computing the coverage ratio — an ICD list with no VCD entries at all
has a coverage ratio of 0.0 and is not compliant.
- Allowing a self-referential interface (source equals destination) to
enter the coverage trace — such an entry has no meaningful bilateral
verification context and must be flagged at the ICD validation step.
## Behavior contract (gate 3)
The ICD validation, VCD validation, trace, and coverage logic is
exercised by the gate 3 contract test:
scripts/test_e1024_verif.py against scripts/e1024_verif_logic.py
(stdlib unittest, offline). Run:
python3 scripts/test_e1024_verif.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.