name: e1024-ref-data
description: "Use when define the interface reference data list for a space system
development project under ECSS-E-ST-10-24C Annex E: identify each interface type
(electrical, mechanical, thermal, data, RF, optical, fluid, pyrotechnic), specify
typical parameters with measurement units and value ranges, assign a format token
per parameter entry, verify that every record contains all required fields, and
group entries by interface type to produce a structured reference table. Apply
during ICD development, interface requirement capture, or compliance review of
interface documentation. Trigger: ecss, e-st-10-system-scope, e-st-10-24c,
interface-management, icd, interface-reference-data, parameter-list, units,
formats, interface-types."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-10-system-scope, e-st-10-24c, interface-management, icd, interface-reference-data, parameter-list, units, formats]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Interface Management — Interface Reference Data (space-systems/ecss/e1024-ref-data)
Use when the task is defining the interface reference data list for a space
system project per ECSS-E-ST-10-24C Annex E (informative): determining the
canonical parameter set per interface type, assigning units and format tokens,
and verifying each parameter record is complete before aggregating into a
structured reference table used as the basis for Interface Control Documents.
## Domain quick reference
- Annex E of ECSS-E-ST-10-24C defines a reference set of typical interface
parameters, their measurement units, acceptable formats, and value ranges,
grouped by interface type. The annex is informative; projects may extend the
parameter set but must maintain structural completeness.
- Eight interface types are recognised: electrical (voltage, current, power,
impedance), mechanical (mass, dimensions, torque), thermal (temperature range,
conductance, dissipation), data (rate, protocol, frame structure), RF
(frequency, power, polarisation), optical (wavelength, aperture, field of
view), fluid (pressure, flow rate), and pyrotechnic (firing current, voltage,
timing). Each type has its own accepted unit set; a unit from one type's set
is not valid for another type's parameters.
- Every parameter record requires five fields: interface_type, parameter_name,
unit, format, and value_range. A record with any field blank or absent is
incomplete and must be resolved before the reference table is considered ready
for ICD attachment.
- Format tokens are drawn from a fixed vocabulary: float, int, enum, string,
bool, hex, binary. Each token may be followed by a bracketed range or
enumeration to tighten the constraint; an unrecognised token blocks downstream
parsing.
## Workflow
1. Inventory all interfaces in the project and, for each one, identify its type
from the canonical set of eight. Reject any unrecognised type before the
record enters the reference table — the type drives unit and format
validation in every subsequent step.
2. For each interface type, enumerate the parameters that must be documented.
Use the Annex E reference set as the starting point: electrical parameters
include bus voltage, current limit, inrush current, impedance, and power;
mechanical parameters include mass, envelope dimensions, bolt torque, and
fundamental frequency; thermal parameters include operating temperature range,
maximum allowable power dissipation, and interface thermal conductance; data
parameters include nominal data rate, protocol identifier, and frame or
packet size; RF parameters include centre frequency, transmit power, and
polarisation sense; optical parameters include centre wavelength, aperture
diameter, and field of view; fluid parameters include nominal supply pressure
and maximum flow rate; pyrotechnic parameters include no-fire current, all-fire
current, and pulse duration.
3. For each parameter, select the measurement unit from the accepted unit set for
that interface type. Flag any unit that does not belong to the type's set —
the presence of a unit from another type's set typically indicates a copy
error in the ICD row.
4. Assign a format token (float, int, enum, string, bool, hex, binary) to each
parameter and append the value range or enumeration. Flag any token not in the
accepted vocabulary; do not infer or substitute a non-standard token.
5. Verify that every parameter record contains all five required fields with
non-blank values. Collect all findings before returning results; do not stop
on the first missing field, as a batch view of incomplete records is more
actionable than a one-at-a-time report.
6. Group validated records by interface type to produce the reference table.
Records with unresolvable type errors are held in a separate error bucket;
the table is not ready for ICD attachment until the error bucket is empty.
## Pitfalls
- Assigning a unit from a different interface type's accepted set (e.g. kg for
an electrical parameter) — units are type-specific and cross-type assignment
is a data error, not a conservative choice.
- Using a descriptive token such as "number" or "real" instead of "float" or
"int" — the format token vocabulary is fixed; informal synonyms are not
substitutes and will fail downstream validation.
- Leaving value_range blank and treating the record as structurally complete —
an unset range means the constraint was never captured; the record must be
resolved before the table can be used in an ICD.
- Treating Annex E as normative — the annex is informative; it provides a
representative parameter set that projects extend or restrict. The validation
logic (required fields, accepted units, accepted format tokens) applies
regardless of whether a given parameter appears in the Annex E list.
## Behavior contract (gate 3)
The interface-type validation, unit-set checking, format-token checking,
required-field verification, and table-grouping logic are exercised by the
gate 3 contract test: scripts/test_e1024_ref_data.py against
scripts/e1024_ref_data_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e1024_ref_data.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase
per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.