Use when run element-level general tests per ECSS-E-ST-10-03C §6.5.1 to verify that all mechanical functions and electrical performance parameters of a space element meet their acceptance requirements: categorize each test item as mechanical-functional (deployment, retraction, separation, latch-release) or electrical-functional (continuity, insulation resistance, bonding); evaluate each measured parameter against its lower and upper acceptance limits; flag any pre-test or post-test inspection...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e1003-el-general-tests --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E1003 El General Tests?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e1003-el-general-tests)More formats (shields.io, HTML) on the badges page.
---
name: e1003-el-general-tests
description: "Use when run element-level general tests per ECSS-E-ST-10-03C §6.5.1 to verify that all mechanical functions and electrical performance parameters of a space element meet their acceptance requirements: categorize each test item as mechanical-functional (deployment, retraction, separation, latch-release) or electrical-functional (continuity, insulation resistance, bonding); evaluate each measured parameter against its lower and upper acceptance limits; flag any pre-test or post-test inspection failure before accepting results; and confirm the complete set of required test items has been performed before releasing the element for integration. Trigger: ecss, e-st-10-system-scope, e1003, element-general-tests, mechanical-functional, electrical-functional, deployment-test, insulation-resistance, element-acceptance."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-10-system-scope, e1003, element-general-tests, mechanical-functional, electrical-functional, deployment-test, insulation-resistance]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Element General Tests (space-systems/ecss/e1003-el-general-tests)
Use when the task is running element-level general tests under
ECSS-E-ST-10-03C §6.5.1: executing mechanical functional tests
(§6.5.1.2) and electrical functional tests to verify that all
mechanical functions and electrical performance parameters satisfy
acceptance requirements before the element advances to integration.
## Domain quick reference
- ECSS-E-ST-10-03C §6.5.1 splits element-level general tests into
two families: mechanical-functional tests and electrical-functional
tests. Each test item belongs to exactly one family.
- Mechanical-functional tests (§6.5.1.2) verify that every mechanical
function of the element operates correctly -- deployments, retractions,
separations, and latch-releases are typical examples. Each test
measures a parameter (force, torque, displacement, cycle count) and
evaluates it against a lower and an upper acceptance limit.
- Electrical-functional tests verify electrical performance of the
element harness and interfaces: continuity checks confirm a conducting
path meets its maximum resistance budget; insulation-resistance checks
confirm that galvanically isolated circuits maintain separation above
a minimum resistance threshold; bonding checks confirm that
structural-ground paths meet their upper resistance limit.
- Every test item requires a pre-test inspection (physical check of
the item and test setup before applying stimulus) and a post-test
inspection (check for damage or anomaly after the stimulus). A
pre-test inspection failure halts the individual test before any
measurement is taken; a post-test inspection failure invalidates the
result even if the measured value was within limits.
- The element may not be released for integration until every required
test item has been performed and every item verdict is a pass.
## Workflow
1. For each test item in the element test plan, record: its unique test
identifier, its test type (mechanical-functional or
electrical-functional), the outcome of the pre-test inspection, the
measured value, the lower acceptance limit, the upper acceptance
limit, and the outcome of the post-test inspection.
2. Categorize each test item -- reject any item whose test type is not
one of the two recognized families before it enters evaluation.
3. Evaluate the pre-test inspection: if it did not pass, assign verdict
"pre_inspection_fail" and do not proceed to the measurement
comparison for that item.
4. Evaluate the measured value against the acceptance limits: if the
value is below the lower limit or above the upper limit, assign
verdict "out_of_limits".
5. Evaluate the post-test inspection: if it did not pass, assign verdict
"post_inspection_fail" even when the measurement was within limits.
6. Assign verdict "pass" only when the pre-test inspection passed, the
measured value is within both limits (inclusive), and the post-test
inspection passed.
7. Confirm that every required test item identifier has a result entry;
flag any required item that has no result as "not_performed".
8. Determine element release readiness: the element may proceed to
integration only when no required item is missing and every item
verdict is a pass.
## Pitfalls
- Accepting a measurement that is within limits while the post-test
inspection found damage -- a failed post-test inspection is a
standalone finding that invalidates the result regardless of the
numeric outcome.
- Skipping the pre-test inspection and proceeding directly to stimulus
application -- an anomaly present before the test cannot be
attributed to the test itself without this reference check.
- Treating a missing required test item as a pass because no failure
was recorded -- a test that was never performed is neither a pass nor
a fail; it is an open item that must be dispositioned before release.
- Applying a mechanical-functional acceptance limit (e.g. a force band)
to an electrical-functional parameter or vice versa -- the limit
values are type-specific and mixing them produces an undefined
comparison.
## Behavior contract (gate 3)
The test-type categorization, measurement limit evaluation,
inspection gating, and element release readiness logic is exercised
by the gate 3 contract test:
scripts/test_e1003_el_general_tests.py against
scripts/e1003_el_general_tests_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e1003_el_general_tests.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.