Tune and benchmark a healthy Ceph cluster, with Rook-on-Kubernetes specifics: mClock profiles and the NVMe capacity-fallback trap (osd_mclock_max_capacity_iops), osd_memory_target from pod requests, BlueStore allocation and cache defaults, PG autoscaler targets (mon_target_pg_per_osd, bulk, target_size_ratio), public/cluster network and Multus choices, msgr2 modes, Tentacle Fast EC (allow_ec_optimizations, stripe_unit), krbd vs rbd-nbd in ceph-csi, librbd cache, and benchmark method (rados be...

  • 5 stars
  • 0 votes
  • 0 copies
  • 2 views
  • Added September 24, 2026
ai-agentsgokubernetesperformance

Works with

  • cli

Security analysis

A100/100

Pro scans all 8 files and shows the line behind each finding

Scanned September 24, 2026

npx -y skills add air-gapped/skills --skill ceph-performance --agent claude-code

Installs into .claude/skills of the current project.

Are you the author of Ceph Performance?

Add the live security badge to your README. It updates with every re-scan.

Security grade badge for Ceph Performance
[![Security: A — Skills Directory](https://www.skillsdirectory.com/api/skills/air-gapped-ceph-performance/badge)](https://www.skillsdirectory.com/skills/air-gapped-ceph-performance)

More formats (shields.io, HTML) on the badges page. Keep it an A: scan every change in CI with Pro.

Download with Pro
SKILL.md
---
name: ceph-performance
description: >-
  Tune and benchmark a healthy Ceph cluster, with Rook-on-Kubernetes
  specifics: mClock profiles and the NVMe capacity-fallback trap
  (osd_mclock_max_capacity_iops), osd_memory_target from pod requests,
  BlueStore allocation and cache defaults, PG autoscaler targets
  (mon_target_pg_per_osd, bulk, target_size_ratio), public/cluster network
  and Multus choices, msgr2 modes, Tentacle Fast EC (allow_ec_optimizations,
  stripe_unit), krbd vs rbd-nbd in ceph-csi, librbd cache, and benchmark
  method (rados bench, rbd bench, fio). Squid 19.2 and Tentacle 20.2.
when_to_use: >-
  Use when making a working Ceph cluster faster or sizing one: "ceph
  performance", "tune ceph", "mclock profile", "osd_mclock_max_capacity_iops",
  "NVMe OSD slow", "IOPS lower than expected", "osd_memory_target", "OSD
  memory sizing rook", "bluestore_min_alloc_size", "pg autoscaler",
  "mon_target_pg_per_osd", "how many PGs", "bulk pool", "cluster network",
  "public network", "multus ceph", "host network rook", "msgr2 secure mode
  overhead", "erasure coding performance", "allow_ec_optimizations", "fast
  EC", "stripe_unit", "crimson", "seastore", "krbd vs rbd-nbd", "rbd cache",
  "rados bench", "fio rbd", "benchmark ceph". NOT for a degraded or
  erroring cluster (slow recovery, slow ops, full OSDs) — that is
  ceph-troubleshooting; upgrades are rook-ceph-best-practices; RGW/S3
  behaviour is ceph-s3.
argument-hint: "[mclock|memory|pg|network|ec|client|bench] (optional focus area)"
---

# ceph-performance

Defaults read from `src/common/options/*.yaml.in` at v19.2.6 and v20.2.4,
docs.ceph.com (tentacle pages) and Rook docs at v1.20.7, on **2026-09-23**.
Measure before and after every change; `ceph config show osd.N <opt>` is
the value actually in force.

## mClock: the NVMe capacity trap

mClock sizes every reservation from each OSD's measured IOPS capacity. At
OSD start an `osd bench` sets `osd_mclock_max_capacity_iops_{hdd,ssd}`.
If the result exceeds the sanity threshold — **500 (HDD), 80 000 (SSD)** —
it is discarded and the OSD falls back to the default capacity
(**21 500** SSD) with a cluster-log warning. Modern NVMe routinely exceeds
80 000, so mClock under-drives it.

1. `ceph config show osd.N osd_mclock_max_capacity_iops_ssd` on every OSD;
   `21500` means the fallback hit.
2. Measure the device with fio at 4 KiB random write, then
   `ceph config set osd.N osd_mclock_max_capacity_iops_ssd <iops>`.
3. Re-check after replacing a device — the value is per OSD.

Profiles: `balanced` is the default from 17.2.7 and in Reef, Squid and
Tentacle (17.2.0–17.2.6 shipped `high_client_ops`). Use `high_client_ops`
for latency-sensitive steady state, `high_recovery_ops` only for a
maintenance window.

## Memory

- Under Rook, Ceph reads `POD_MEMORY_REQUEST` and uses it 1:1 as
  `osd_memory_target`; with only a limit, target = limit ×
  `osd_memory_target_cgroup_limit_ratio` (0.8). Set requests and limits
  explicitly on `spec.resources.osd`; the limit needs headroom above the
  request because the target is a cache-trim goal, not a cap. Confirm with
  `ceph config show osd.N osd_memory_target` after the pods restart.
- Rook's own minimums (warns below): osd 2048 MB, mon 1024 MB, mgr 512 MB.
  4 GiB+ per OSD is the Ceph default target; NVMe OSDs benefit from more.
- `bluestore_cache_autotune` is on by default; `osd_memory_target_autotune`
  (cephadm) is off and irrelevant under Rook.
- `mds_cache_memory_limit` defaults to 4 GiB; the MDS uses more than this —
  size its pod limit well above it.

## BlueStore allocation

`bluestore_min_alloc_size_hdd` and `_ssd` are both **4 KiB**. The "64 KiB
on HDD" advice is obsolete. The value is baked in at OSD creation; changing
it needs the OSD redeployed.

## PG autoscaler

| Knob | Default | Guidance |
|---|---|---|
| `mon_target_pg_per_osd` (mgr option) | 100 | Docs recommend **200** for all but the smallest clusters; above 500 costs peering and RAM |
| pool `bulk` flag | false | Set on pools that will hold most of the data so they start with a full PG count instead of growing |
| `target_size_ratio` | unset | Set on each large pool; otherwise the autoscaler sizes from current usage only |
| `pg_num_min` / `pg_num_max` | unset | Bound pools the autoscaler keeps shrinking |

## Network

- A separate cluster network is **optional**: current docs say public-only
  "functions just fine … especially with 25GE or faster"; add one for high
  client traffic or ≤10 GE links.
- Rook: host networking removes pod-network latency but gives no isolation;
  Multus gives isolation — use CNI `macvlan` with `whereabouts` IPAM (the
  documented path). Validate with `kubectl rook-ceph multus validation run`.
- msgr2 mode defaults are `crc secure` for cluster, service and client:
  CRC is used unless a peer requires secure. Forcing `secure` everywhere
  encrypts all traffic and costs CPU/throughput — benchmark before and after.

## Erasure coding (Tentacle)

- New pools default to the **ISA-L** plugin (Jerasure before); existing
  pools keep their plugin on upgrade.
- Fast EC: `ceph osd pool set <pool> allow_ec_optimizations true` — partial
  reads/writes, parity-delta writes; 2–3× small-I/O gains in Ceph's own
  benchmark. **Irreversible** for the pool. Works with Jerasure and ISA-L
  `reed_sol_van`.
- `stripe_unit` is fixed at pool creation: 16 KiB for general workloads,
  up to 256 KiB for read-heavy; the old 4 KiB default gains less. Create a
  new pool rather than flipping the flag on an old 4 KiB one.
- Do not enable it on 20.2.0: turning it on for a pool that already had
  `ec_overwrites` crash-looped OSDs (`interval_set.h:365`).
- Replicated size 3 still outperforms EC; EC wins on cost per byte.

## Crimson / SeaStore

Tentacle docs: "tech preview stage and is not suitable for production use".
Do not recommend it for production.

## Clients (ceph-csi)

- RBD PVCs use **krbd** by default. `mounter: rbd-nbd` is Alpha, not for
  production. CephFS uses the kernel client by default, ceph-fuse on request.
- librbd cache settings (`rbd_cache` true, `rbd_cache_policy`
  `writearound`, `rbd_readahead_max_bytes` 512 KiB) apply to librbd and
  rbd-nbd only — they do nothing for krbd PVCs.

## Benchmarking

| Layer | Tool | Watch |
|---|---|---|
| RADOS | `rados bench -p <pool> 60 write --no-cleanup`, then `seq` / `rand`, then `rados -p <pool> cleanup` | Without `--no-cleanup` the read phases have nothing to read |
| RBD | `rbd bench --io-type write --io-size 4K --io-pattern rand` | Bypasses the kernel; not what a krbd PVC sees |
| PVC path | fio inside a pod on the PVC (`--direct=1`) | Matches krbd + filesystem, the real client path |
| Cluster-wide | CBT (`ceph/cbt`) | Repeatable multi-client runs |

Run several clients in parallel — one client cannot saturate a cluster —
and use a dataset larger than the OSD caches.

## Field reports

| Report | Source |
|---|---|
| 18.2.4 → 20.2.1 on hybrid HDD + NVMe-DB clusters: RGW PUT latency 3–4×, DB-device IOPS near zero; unresolved | ceph-users 2026-07-09 |

## References

- `references/sources.md` — every source with its verification stamp.
- Sibling skills: `ceph-troubleshooting`, `rook-ceph-best-practices`,
  `ceph-s3`.

Files in this skill

  • SKILL.md7.1 KB
  • evals/benchmark.json31.9 KB
  • evals/benchmark.md398 B
  • evals/evals.json7.2 KB
  • references/improvement-backlog.md452 B
  • references/knowledge-claims.json5 KB
  • references/sources.md3.6 KB
  • references/trigger-evals.json6.5 KB

Attribution

Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.

Comments

Loading comments…

Newsletter

Get the weekly list of safe new skills, and the ones we pulled.